background image

5

GENERAL INFORMATION

1. 

Installation  must  conform  with  local  codes  or,  in  the 

absence of  local codes, with the 

National Fuel Gas Code

ANSI  Z223.1-Latest  Edition. 

 

2. 

Installation  in  manufactured  (mobile)  home:  installation 

must conform with the 

Manufactured Home Construction 

and  Safety  Standard,  Title  24  CFR,  Part  3280  [formerly 

the Federal Standard for Mobile Home Construction and 

Safety,  Title  24,  HUD  (Part  280)]

  or,  when  such  standard 

is  not  applicable,  the  Standard  for 

Manufactured  Home 

Installations,  ANSI/NCSBCS  A225.1

,  or  with  local  codes 

where  applicable.

3. 

Installation  in  Recreational  Park  Trailers:  installation  must 

conforms  with  state  or  other  codes  or,  in  the  absence 

of  such  codes,  with  the  Standard  for 

Recreational  Park 

Trailers,  ANSI    A119.5

.

4. 

  WARNING!!

 

This  appliance  shall  not  be  used  for  space  heating.  This 

information  is  based  on  safety  considerations.

5. AlI openings in the wall behind the appliance and in the floor 

under  the  appliance  shall  be  sealed.

6. Keep  appliance  area  clear  and  free  from  combustible 

materials,  gasoline,  and  other  flammable  vapors.

7. Do  not  obstruct  the  flow  of  combustion  and  ventilation  air.

8. Disconnect  the  electrical  supply  to  the  appliance  before 

servicing.

9. When  removing  appliance  for  cleaning  and/or  service;
  A.  Shut  off  gas  at  main  supply.
  B.  Disconnect  AC  power  supply.
  C.  Disconnect  gas  line  to  the  inlet  pipe.
  D.  Carefully  remove  the  range  by  pulling  outward.

CAUTION

:  Range  is  heavy;  use  care  in  handling.

10. 

Electrical  Requirement

 

Electrical installation should comply with national and local 

codes.

11. 

Air  Supply  and  Ventilation

 

The  installer  must  refers  to  local/national  codes.

12. 

Gas  Manifold  Pressure

 

Natural  gas  -    4.0”  W.C.P.

 

LP/Propane  -  11.0”  W.C.P.

13.  The  misuse  of  oven  door  (e.g.  stepping,  sitting,  or  leaning 

on  them)  can  result  in  potential  hazards  and/or  injuries.

14. When installing or removing the range for service, a rolling 

lift  jack  should  be  used.  Do  not  push  against  any  of  the 

edges  of  the  range  in  an  attempt  to  slide  it  into  or  out  of 

the installation. Pushing or pulling a range (rather than using 

a lift jack) also increases the possibility of bending the leg 

spindles  or  the  internal  coupling  connectors.

 

    WARNING!!

ELECTRICAL  GROUNDING  INSTRUCTIONS

The  range  must  be  electrically  grounded  in  accordance 

with local codes or, in the absence of local codes, with the 

National  Electrical  Code,  ANSI/NFPA  No.  70-latest  edition. 

Installation  should  be  made  by  a  Iicensed  electrician.

FOR  PERSONAL  SAFETY,  THIS  APPLIANCE  MUST  BE 

PROPERLY  GROUNDED.
 

If  an  external  electrical  source  is  utilized,  the  installation  must 

be  electrically  grounded  in  accordance  with  local  codes  or,  in 

the  absence  of  local  codes,  with  the  national  Electrical  Code, 

ANSI/NFPA  70.

This  appliance  is  equipped  with  a  three-prong  grounding 

plug  for  your  protection  against  shock  hazard  and  should  be 

plugged  directly  into  a  properly  grounded  socket. 

Do  not  under  any  circumstances  cut  or  remove  the    third 

(ground)  prong  from  the  power  plug.

REPLACEMENT  PARTS

Only authorized replacement parts may be used in performing 

service  on  the  range.  Replacement  parts  are  available  from 

factory authorized parts distributors. Contact the nearest parts 

distributor  in  your  area.

Содержание VEFSGG 244

Страница 1: ...ty Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Hom...

Страница 2: ...ighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency...

Страница 3: ...f domestic household food and in not suitable for any none domestic application and therefore should not be used in a commercial environmement The appliance guarantee will be void if the appliance is...

Страница 4: ...lified installer service agent or the gas supplier IMPORTANT The use of suitable protective clothing gloves is recommended when handling installing of this appliance INSTALLATION INSTRUCTIONS TOOLS NE...

Страница 5: ...lation should comply with national and local codes 11 Air Supply and Ventilation The installer must refers to local national codes 12 Gas Manifold Pressure Natural gas 4 0 W C P LP Propane 11 0 W C P...

Страница 6: ...rfaces above 36 914 mm high There must be a minimum of 3 76 mm side clearance from the range to such combustible surfaces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of...

Страница 7: ...13 max 330 mm 914 mm 36 0 0 mm 20 min 500 mm 30 min 762 mm 457 mm 18 min PROXIMITY TO SIDE CABINETS Fig 1 3b ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backguard as...

Страница 8: ...o be attached as shown on figure below only rear right side it has to be fixed on the floor and on the rear wall by no 4 four suitable screws not supplied 2 After fixing the anti tip bracket slide ran...

Страница 9: ...cal gas supplier See page from 13 to 16 for L P gas conversion instructions 1 Manual Shut off Valve fig 2 1 A manual shut off valve must be installed in an accessible location in the gas line external...

Страница 10: ...ch Do not over tighten the connector Over tightening may crack regulator STEP 2 Assemble the 1 2 NPT connector pressure regulator group to the extension pipe interposing the gasket supplied The regula...

Страница 11: ...cal male 1 2 NPT female 1 2 NPT female WARNING check the right positioning of the gas regulator The arrow on the back of the gas regulator must be oriented toward the connector Arrow Extension pipe fe...

Страница 12: ...range can withstand a maximum input pressure of 1 2 PSI 14 0 W C P If the line pressure is in excess of that amount a step down regulator will be required e The appliance its individual shut off valve...

Страница 13: ...ers expressed in hundredths of a millimetre are marked on the body of each injector SETTING THE PRESSURE REGULATOR fig 2 6b The pressure regulator is accessible by removing the bottom drawer the press...

Страница 14: ...ratings the burner covers and the knobs Using a wrench substitute the nozzle injectors J figs 2 7 2 8 with those most suitable for the kind of gas for which it is to be used The burner are conceived i...

Страница 15: ...indicated by the arrow in fig 2 11 and replace it by the proper one according to the kind of gas Then replace the burner repeating the above steps in reverse order b Broil Burner Remove the burner by...

Страница 16: ...one only for the oven burner the broil is a fixed capacity by acting on the thermostat in the following way Turn on the burner by setting the thermostat knob on position Remove the knob and unscrew th...

Страница 17: ...personal safety this range must be grounded This range is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong ground type outlet ground...

Страница 18: ...18 WIRING DIAGRAM Fig 3 2...

Страница 19: ...19 19...

Страница 20: ...anscription errors in the present booklet The manufacturer re serves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and withou...

Отзывы: