background image

IMPORTANT - PLEASE READ AND FOLLOW

✓ 

Before beginning, please read these instructions completely and carefully.

✓ 

Do not remove permanently affixed labels, warnings, or plates from the product. This 

may void the warranty.

✓ 

Please observe all local and national codes and ordinances.

✓ 

Please ensure that this product is properly grounded.

✓ 

The installer should leave these instructions with the consumer who should retain 

for local inspector's use and for future reference.

✓ 

The electrical plug should always be accessible.

Installation must conform with local codes or in the absence of codes, the National Fuel 

Gas  Code  ANSIZ223.1  -  Iatest  edition.  Electrical  installation  must  be  in  accordance 

with  the  National  Electrical  Code,  ANSI/NFPA70  -  latest  edition  and/or  local  codes.  IN 

CANADA: Installation must be in accordance with the current CAN/CGA-B149.1 National 

Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes. 

Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical 

Codes Part 1 and/or local codes.
INSTALLATION  IN  MANUFACTURED  (MOBILE)  HOME:  The  installation  must  conform 

with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 

[formerly  the  Federal  Standard  for  Mobile  Home  Construction  and  Safety,  Title  24,  HUD 

(Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home 

Installations, ANSI/NCSBCS A225.1, or with local codes where applicable.
INSTALLATION IN RECREATIONAL PARK TRAILERS: The installation must conform with 

state or other codes or, in the absence of such codes, with the Standard for Recreational 

Park Trailers, ANSI A119.5. 
Installation of any gas-fired equipment should be made by a Iicensed plumber. A manual 

shut-off valve must be installed in an accessible location in the gas line external to the appli-

ance for the purpose of turning on or shutting off gas to the appliance (In Massachusetts 

such shutoff devices should be approved by the Board of State Examiners of Plumbers & 

Gas Fitters).
If an external electrical source is utilized, the appliance, when installed, must be electri-

cally grounded in accordance with local codes or, in the absence of local codes, with the 

national Electrical Code, ANSI/NFPA 70.

This  range  is  supplied  with  a  protective  film  on

  steel  and  aluminium  parts.

This  film  must  be  removed  before  installing/using  the  appliance.

FOR INSTALLER ONLY

THIS RANGE IS FOR RESIDENTIAL USE ONLY

•  INSTALLATION INSTRUCTIONS

  IMPORTANT - PLEASE READ AND FOLLOW

for  residential  use  only

Model: 

VEFSGG 244 ..

SINGLE OVEN GAS RANGE

Содержание VEFSGG 244

Страница 1: ...ty Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Hom...

Страница 2: ...ighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency...

Страница 3: ...f domestic household food and in not suitable for any none domestic application and therefore should not be used in a commercial environmement The appliance guarantee will be void if the appliance is...

Страница 4: ...lified installer service agent or the gas supplier IMPORTANT The use of suitable protective clothing gloves is recommended when handling installing of this appliance INSTALLATION INSTRUCTIONS TOOLS NE...

Страница 5: ...lation should comply with national and local codes 11 Air Supply and Ventilation The installer must refers to local national codes 12 Gas Manifold Pressure Natural gas 4 0 W C P LP Propane 11 0 W C P...

Страница 6: ...rfaces above 36 914 mm high There must be a minimum of 3 76 mm side clearance from the range to such combustible surfaces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of...

Страница 7: ...13 max 330 mm 914 mm 36 0 0 mm 20 min 500 mm 30 min 762 mm 457 mm 18 min PROXIMITY TO SIDE CABINETS Fig 1 3b ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backguard as...

Страница 8: ...o be attached as shown on figure below only rear right side it has to be fixed on the floor and on the rear wall by no 4 four suitable screws not supplied 2 After fixing the anti tip bracket slide ran...

Страница 9: ...cal gas supplier See page from 13 to 16 for L P gas conversion instructions 1 Manual Shut off Valve fig 2 1 A manual shut off valve must be installed in an accessible location in the gas line external...

Страница 10: ...ch Do not over tighten the connector Over tightening may crack regulator STEP 2 Assemble the 1 2 NPT connector pressure regulator group to the extension pipe interposing the gasket supplied The regula...

Страница 11: ...cal male 1 2 NPT female 1 2 NPT female WARNING check the right positioning of the gas regulator The arrow on the back of the gas regulator must be oriented toward the connector Arrow Extension pipe fe...

Страница 12: ...range can withstand a maximum input pressure of 1 2 PSI 14 0 W C P If the line pressure is in excess of that amount a step down regulator will be required e The appliance its individual shut off valve...

Страница 13: ...ers expressed in hundredths of a millimetre are marked on the body of each injector SETTING THE PRESSURE REGULATOR fig 2 6b The pressure regulator is accessible by removing the bottom drawer the press...

Страница 14: ...ratings the burner covers and the knobs Using a wrench substitute the nozzle injectors J figs 2 7 2 8 with those most suitable for the kind of gas for which it is to be used The burner are conceived i...

Страница 15: ...indicated by the arrow in fig 2 11 and replace it by the proper one according to the kind of gas Then replace the burner repeating the above steps in reverse order b Broil Burner Remove the burner by...

Страница 16: ...one only for the oven burner the broil is a fixed capacity by acting on the thermostat in the following way Turn on the burner by setting the thermostat knob on position Remove the knob and unscrew th...

Страница 17: ...personal safety this range must be grounded This range is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong ground type outlet ground...

Страница 18: ...18 WIRING DIAGRAM Fig 3 2...

Страница 19: ...19 19...

Страница 20: ...anscription errors in the present booklet The manufacturer re serves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and withou...

Отзывы: