24
3-Wire Conduit Installation
(See Figures 3.1, 3.5 and 3.6)
1. Remove the
Terminal Block Access Plate on the back of the
range by unscrewing the 6 fixing
Screws (fig. 3.1).
2. Feed 1/2” (1.3 cm) trade size
Conduit through the hole in the
Conduit Bracket and secure to the Conduit Bracket with a
Conduit Clamp.
3. Remove the 3 wire terminal nuts and washers from the
Terminal Block.
4. Plug the terminal holes of conductors. The
Neutral or
Ground Wire of the Power Cord must be connected to the
neutral terminal located in the center of
Terminal Block. The
Power Wires must be connected to the outside terminals.
5. Plug washers and tighten nuts securely.
Do not remove
Ground strap.
6. Assemble the
Terminal Block Access Plate.
4-Wire Conduit Installation
(See Figures 3.1, 3.5 and 3.7)
1. Remove the
Terminal Block Access Plate on the back of the
range by unscrewing the 6 fixing
Screws (fig. 3.1).
2. Feed 1/2” (1.3 cm) trade size
Conduit through the hole in the
Conduit Bracket and secure to the Conduit Bracket with a
Conduit Clamp.
3. Remove the 3 wire terminal nuts and washers from the
Terminal Block.
4. Remove the
Ground Strap from the frame of range and
terminal by removing its screw and cutting it as shown in
Figure 3.7.
5. Plug the terminal holes of conductors. The
Neutral Wire of
the
Power Cord must be connected to the neutral terminal
located in the center of
Terminal Block; the Power Wires
must be connected to the outside terminals; the
Ground
Wire must be attached to the frame of range by using the
(Ground) identified
Grounding Screw.
6. Plug washers and tighten nuts securely.
7. Assemble the
Terminal Block Access Plate.
Hole D 7/8"
(22.5 mm)
Counduit
Bracket
Power Wires
Terminal Block
Ground strap
Neutral Wire
Conduit
Conduit Clamp
Power Wires
Terminal Block
Neutral Wire
Grounding Wire
Cut Ground Strap
Grounding
Screw
Conduit
Conduit Clamp
Fig. 3.5
Fig. 3.6
Fig. 3.7