background image

 

 

INSTALLATION 

1.  UNDER CABINET OR SOFFIT INSTALLATION 

a.

 

Make sure all preparation steps are completed. 

b.

 

Connect 6” black collar to hood. (1)  Using screws provided 

c.

 

If using transition, connect transition with damper to 

6” black collar, 

wider part to front (2) 

d.

 

Secure collar and transition with sheetmetal screws and/or duct 

tape for an air-tight seal.  

Do not impede damper movement.

 (3) 

e.

 

Cutout hole 

for 6” or 7” diameter duct exhaust hole in cabinet or 

soffit, per figure 1C.  

Recommended attaching 6” collar & 7” 

transition (with damper) to hood before setting into place.

 

f.

 

Drill Wiring Access hole in cabinet per figure 1C.  (If not using a 

plug), feed the wires coming down into top of the hood through the 

opening in the  bottom of the cabinet. (For recirculation kit 

installation, you must  feed wires through recirculation vent before 

going into hood) 

g.

 

Using the screws provided, fasten 4 hood screws into cabinet or 

soffit at location identified.  

DO NOT SCREW IN ALL THE WAY, 

LEAVE 1/8” OF SCREW SHOWING

.  

h.

 

Lift the hood up to the cabinet, such that the screws protrude 

through the key holes on hood top.  Push hood back flush against 

the wall, so that screws support hood. 

i.

 

While holding hood, tighten all 4 screws securely from under the  

hood.   

j.

 

NOTE: Install additional screws through the back or top for 

security. 

 

2.  CONNECT DUCTWORK 

 

a. 

Connect 6” or 7” metal duct to collar or 
transition.  

 
Your METAL Exterior Exhaust Outlet (Purchased Separately), 
 installed at the end of your duct run on the roof or outer wall  
of your home must include an integrated damper to block the 
 intrusion of outside air into the home.   

 

1.

 

 

 

 

2.

 

 

3. 

Содержание Under Cabinet Series

Страница 1: ...nge hood Store it in a safe location for when you need to reference it in the future NOTE PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED This unit is designed for indoor residential use only DO NOT USE OVER A WOOD GRILL OR MOUNT IN OUTDOOR ENVIRONMENT ...

Страница 2: ...ALLATION 10 OPERATION FEATURES 11 CLEANING MAINTENANCE 12 TROUBLESHOOTING 13 PARTS LIST REPLACEMENT 14 WIRING DIAGRAM 15 WARRANTY CONTACT US 16 17 HOOD SPECIFICATIONS 36 W x 10 H x 22 D 600 CFM Hood construction 430 Stainless Steel 120V 60Hz 3 0 A Verona Hood VEHOOD3610 can be installed using outside venting or by use of a re circulating kit ...

Страница 3: ...per combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Because the unit i...

Страница 4: ...ize of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL 911 NEVER PICK UP A FLAMING PAN Doing so may result in serious burns and possibly spread the ...

Страница 5: ...acket 2 CONTENTS NOT INCLUDED a Recirculation Kit Purchased separately b 6 or 7 Metal ducting 3 TOOLS REQUIRED NOT INCLUDED a Safety gloves b Safety glasses c Electric drill w starter bit d Utility knife e Spirit level f Measuring tape g Writing instrument pen marker pencil h Aluminum or duct tape i Wire nuts Round metal duct length to suit installation ...

Страница 6: ...5 MEASUREMENTS Fig 1a Electrical Opening 1 from Rear 13 from Center 24 36 17 Keyhole 2 from Rear 16 from Center 10 from Rear Centerline ...

Страница 7: ...ertified installer and electrician is recommended g In some jurisdictions make up replacement air is required Check with your local building codes for more details 2 LOCATION a Determine the exact location you want to install the range hood b A centerline should be located on bottom of cabinet or soffit c Distance between cooktop and range hood should be between 24 36 Fig 1b d Range hood should be...

Страница 8: ...f cabinet bottoms are recessed Cabinet opening for exhaust should be 6 diameter if using collar ONLY 8 diameter if using collar 6 7 transition Electrical Opening 1 from Rear 13 from Centerline Place hood under the cabinet to be installed and mark 4 keyholes to drill starter hole Center Line ...

Страница 9: ...ening in the bottom of the cabinet For recirculation kit installation you must feed wires through recirculation vent before going into hood g Using the screws provided fasten 4 hood screws into cabinet or soffit at location identified DO NOT SCREW IN ALL THE WAY LEAVE 1 8 OF SCREW SHOWING h Lift the hood up to the cabinet such that the screws protrude through the key holes on hood top Push hood ba...

Страница 10: ...the source b Make electrical connections with wire nuts Purchased Separately as shown If house wiring is not 2 wire with a ground wire a ground must be provided by the installer 4 Completion a Turn Power back ON from the Circuit or Fuse box b Activate blower and lights to confirm proper function c Remove ALL protective film from the exterior of your hood and filters INSTALLATION Green or Bare Grou...

Страница 11: ...by screwing 4 sheet metal screws provided into the pre dilled holes 5 Follow Installation from page 8 6 Drive machine screws provided into underside of Recirculation Kit leaving a protrusion 7 Install hood to underside of Recirculation Lit onto mounting screws and slide back to rear wall Tighten Screws Add additioal screws to back wall if neccessary 8 Install Charcoal Filters to sides of blower in...

Страница 12: ...n 1 Low 2 Button 2 Medium 3 Button 3 High Light On Off Control 2 MESH FILTERS a 3 10 3 4 x 15 Dishwasher Safe Aluminum Mesh filters 3 PUTTING IN THE MESH FILTERS a Insert the Filter into the unit at an angle Fig 3b b Push the Mesh filter upward Fig 3c c Snap into place Fig 3c 0 1 2 3 Fig 3c Fig 3b ...

Страница 13: ...D a Use household cleaner to remove grease or dirt from the outer shell of the unit Spray on wiping cloth or sponge and wipe in the direction of the grain to avoid scratching the unit DO NOT SPRAY DIRECTLY ONTO UNIT b Stainless steel cleaners can help keep your rangehood bright and clean 2 MESH FILTERS a Clean the Mesh filters regularly for the most efficient suction power b Let it soak thoroughly...

Страница 14: ...orking on the unit Serious injury or death may occur if safety precautions are not followed VEHOOD3610 Series LED Light Issue 1 LED lights may need to be changed Contact EuroChef or replacement bulb Unit Lacks Power 1 Confirm that circuit breaker is ON 2 All wiring is connected Unit making humming noise 1 Replace defective capacitor with new one Fan Blower Fails Call for Service ...

Страница 15: ...p Panel B101 7236 06 3 LED Lamp C1 0403 0306 4 Switch C1 0405 0303 5 Capacitor C1 0401 A250 22 6 LED Driver C1 0402 D001 7 Motor Blower C1 0302 A110 06A 8 Aluminum Filter C1 0604 0107 10 Recirculating Kit Optional RK36 11 Charcoal Filters for Recirculating Kit C1 0603 0303 How to Order Parts Contact Eurochef USA 866 844 6466 or submit a service call at www veronaappliances com 11 10 ...

Страница 16: ...Parts Replacement Wiring Diagram 15 ...

Страница 17: ...f electrical components Parts In addition Verona will supply at no charge new or rebuilt replacements in exchange for defective parts for a period of one 1 year After the warranty period customer must pay for all parts During the parts warranty period there will be no charge for parts You must provide the serial number of your unit for any replacement parts during the warranty period This warranty...

Страница 18: ...per setting of any control Pressing multiple selections at the same time f Improper chemical cleaning commercial or industrial cleaning agents 2 Products purchased for use in a commercial or industrial setting such as in a hotel office restaurant or other business 3 Damage resulting from natural disasters earthquake flood storm etc 4 Aluminum Filters Charcoal Filters and Light Bulbs CONTACT US Ver...

Отзывы: