background image

18

WinterWarm Small Insert

2000888

If replacement of the refractory package is required, 
proceed to #10.
10. Remove 1/4-20 x 1/2” hex head screw from the 
damper tab holding the damper link to the damper and 
let the link drop down.
11. Remove the two (2) 1/4-20 x 1

¹⁄₂

” hex head screws 

and washers holding the damper housing to the stove 
back and drop the damper housing out of the stove.
12. Carefully slide the refractory package out of the 
unit.
13. Install the new refractory package making sure to 
pilot a small hole for the secondary probe in the proper 
location at the back of the refractory package.
14. Reinstall the damper housing and damper link.

Watch for Better Results

Operate the stove in a typical manner for two weeks, 
inspecting the chimney and the chimney connector fre-
quently during this period. If creosote is not building up 
as fast, it is likely the performance change was caused 
by fly ash deposits on the catalytic element. However, 
continue the inspections of the chimney system for a 
few weeks to ensure that proper performance contin-
ues.
If you continue to find a significant creosote build-up 
or if you continue to see excessive smoke from the 
chimney, the catalytic element will need to be replaced.  
Contact your nearest Vermont Castings Authorized 
Dealer for information about a replacement element.

NOTE:

  Use only the replacement catalyst #160-2521 

supplied by CFM Corporation.

The refractory and the catalytic element are 
extremely fragile and must be handled carefully.

The Chimney System

A Clean Chimney System is Safer 

and Works Better

Although the catalytic combustion system in your Win-
terWarm Small Insert can reduce creosote formation 
dramatically, it is not a substitute for regular inspection 
and cleaning of the chimney and chimney connector.

Learn To Recognize — 

And Avoid — Creosote

Your WinterWarm Small Insert has been designed to 
minimize creosote build-up. Regular chimney inspection 
and maintenance, however, must still be performed.  
For safety, good stove performance, and to protect your 
chimney and chimney connector, inspect your chimney 
and chimney connector on a regular schedule.  Clean 
the system if necessary.  Failure to keep the chimney 
and connector system clean can result in a serious 
chimney fire.  
When wood is burned slowly, it produces tar, organic 
vapors and moisture which combine to form creosote.  
The creosote vapors condense in the relatively cool 
chimney flue of a slow-burning fire.  As a result, creo-
sote residue accumulates on the flue lining.  When 
ignited, this creosote makes an extremely hot fire within 
the flue system that can damage the chimney and 
overheat adjacent combustible material.  If a significant 
layer of creosote has accumulated —1/8” (3mm) or 
more — it should be removed to reduce the risk of a 
chimney fire.
If you do experience a chimney fire, act promptly to:

• 

Close the damper and thermostat lever.

• 

Get everyone out of the house.

• 

Call the Fire Department from a nearby house.

You should inspect the system every two weeks during 
the heating season as part of a regular maintenance 
schedule.  To inspect the chimney, let the WinterWarm 
Small Insert cool completely.  Then, using a strong light, 
sight up through the flue collar into the chimney flue. If it 
is not possible to inspect the flue system in this fash-
ion, the firechamber must be removed to provide better 
viewing access. 
If it is necessary to remove the firechamber to inspect 
or clean the chimney, this is how to do it:

• 

Let the WinterWarm Small Insert cool.

• 

Disconnect the fan power cord.

• 

You may wish to lighten the firebox by removing 
the load door, andirons, grate and ash door.

• 

Retract the two levelling screws until they bear no 
weight.

FP1108

WinterWarm

Small Insert

Catalytic element

4/01

Catalytic Element

FP1108

Fig. 19

  The refractory plug is removed to access the catalytic 

element.

Содержание WinterWarm Small Insert 2080

Страница 1: ...LIANCE IS NOT PROPERLY INSTALLED OPERATED AND MAIN TAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Homeowner s Installation and Operating Manual ...

Страница 2: ...lation you have chosen you can count on years of comfortable heating and pleasurable fire view ing if you operate and maintain it according to the directions in this Owner s Guide The WinterWarm Small Insert has been tested and listed by Inchcape Testing Services Warnock Hersey Inc of Middleton Wisconsin according to ANSI UL 1482 for the United States and ULC S628 for Canada The WinterWarm Small In...

Страница 3: ...g on how the unit is operated and the type and moisture content of the fuel used Figure shown is based on maximum fuel con sumption obtained under laboratory conditions and on average efficiencies These values are based on operation in building code conforming homes under typical winter climate conditions in New England If your home is of nonstan dard construction e g unusually well insulated not i...

Страница 4: ...meeting standards for both the firebox and chimney Review the owner s manual and inspect the fireplace for metal tags or labels which give information concerning installation of inserts into the factory built fireplace Codes may permit removal of the damper in order to install a chimney liner Codes may also permit removal of external trim pieces which do not affect the operation of the unit as long a...

Страница 5: ...ce opening Unused openings to the flue must be sealed with masonry to the thickness of the chimney wall Openings sealed with pie plates or wallpaper are a hazard In the event of a chimney fire flames and smoke may be forced from the openings Canada In Canada CAN CSA B365 M91 Section 5 wheth er installed in a m or factory built fireplace A full chimney liner meeting ULC S635 Class III stainless steel m...

Страница 6: ...r more details on mantel and top trim see Note below Where side trim extends more than 2 50mm from the fireplace facing the side clearance must be no less than 20 525mm Measure the side clearance C from the exact center of your fire place opening on the hearth X Measure the top trim B and or mantel clearances A from the finished hearth surface Measure the front clearance to furnishings etc from the fi...

Страница 7: ...hearth irregularities Optional Surround Packages Custom made surround panels may be made from any noncombustible material CFM Corporation offers both steel and cast iron Sur round panel kits each in two sizes Enclosure Area Steel Surround Trim Kits 6 2970 36 x 27 927 x 686 mm 10 2971 44 x 31 1130 x 787 mm Cast Iron Surround Trim Kits 7 2972 40 x 28 1016 x 724 mm 10 2973 45 x 31 1143 x 787 mm Insta...

Страница 8: ...rebox Position the firebox so the flue collar lines up with the connector Use the leveling screws at the front of the Insert to adjust the level Route the power cord to the side nearest the power supply and test the fans 1 35mm FP1097 WWsi starter pipe 4 3 01 djt FP1097 Fireplace Front Fig 8 Install the threaded rod inside the Starter Pipe not a supplied item starter pipe is available from the Chimn...

Страница 9: ...amount of heat desired Fig 9 To complement the manual setting of the air control the WinterWarm Small Insert has an internal automatic thermostat that ensures an even delivery of heat at the manual setting you select 2 00 High 3 00 Medium 4 00 4 30 Low FP1100 WWsi air control settings 4 03 01 djt Primary Air Control Lever FP1100 Fig 9 Settings for the primary air control range from 2 00 high burn ...

Страница 10: ...se excessive temperatures in the WinterWarm Small Insert and could even damage the combustor On the other hand too little draft can cause backpuffing into the room and or the plugging of the chimney or combustor How do you know if your draft is excessively high or low Symptoms of too much draft include an uncontrol lable burn or glowing red cast iron A sign of inadequate draft is smoke leaking into...

Страница 11: ...and cause smoke to spill into the room Coal smoke also can poison the catalyst so that it won t operate properly In general the fire must be sufficiently well established to ensure that catalytic activity is initiated When first starting a fire a medium to high firing rate must be maintained for at least twenty minutes This ensures the stove catalyst and fuel are all stabilized at the proper operating ...

Страница 12: ...2mm has formed close the damper to activate the combustor To ensure continued operation of the combustor let the fire burn hot for an additional ten to fifteen minutes after the damper is closed 5 Close the primary air control to a medium low set ting The fire volume will diminish immediately but the WinterWarm Small Insert will continue to heat up Maintain control of the fire using the primary air co...

Страница 13: ... hot coals and must be treated with extreme care Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan Replace the ash pan and close the ash door and front door FP1103 Ash door 4 04 01 djt Ash Pan Ash Chamber Door Load Door FP1103 Fig 13 Wear heavy stove gloves if it is necessary to handle the ash when hot coals are present Empty the ash pan regularly ...

Страница 14: ... with water will work in most cases Use a glass cleaner especially made for this purpose only if deposits are specially heavy If heavy deposits are a frequent occurrence however evaluate your operating techniques Do not use abrasive cleaners Rinse the glass thoroughly Dry the glass completely NOTE The WinterWarm Small Insert glass is coated with a special material on one side that helps reflect hea...

Страница 15: ...not solved replace the damper gasket Instructions are on Page 16 IMPORTANT NOTES Do not operate the WinterWarm Small Insert if the glass is damaged or broken The glass used in your WinterWarm Small Insert is coated with a special material on one side that reflects heat back into the fire chamber To re place new glass correctly look along the edge of the glass for a printed notice that reads THIS SID...

Страница 16: ...all but a couple inches from the end before you trim the end to an exact fit Replacing the Insert s Door Gaskets Remove the door by lifting it straight up from its hinge pins Lay it face down on a padded surface Remove the glass Follow the instructions for removing and replacing glass which start on page 15 Replace gaskets Follow steps 1 4 above Replace the glass Replace the door Replacing the Damp...

Страница 17: ...oke with steam from wet wood If this test indicates a problem consider other possible factors as well such as the time of year or a change in the quality of your fuel In spring and fall draft is weaker than it is in colder winter weather and fires can burn sluggishly Small hot fires are a good solution under these conditions Burning green insufficiently seasoned wood will result in poorer performance...

Страница 18: ... Avoid Creosote Your WinterWarm Small Insert has been designed to minimize creosote build up Regular chimney inspection and maintenance however must still be performed For safety good stove performance and to protect your chimney and chimney connector inspect your chimney and chimney connector on a regular schedule Clean the system if necessary Failure to keep the chimney and connector system clea...

Страница 19: ...e round brush and enough rods to clean the entire length of the flue If you can t do the chimney inspection yourself con tact your local Vermont Castings Authorized Dealer or engage a professional chimney sweep to perform the inspection and cleaning of the chimney Reverse the procedure to re install the firechamber Fireplace System Maintenance Schedule Fireplace Daily Ash should be removed before th...

Страница 20: ...gases and because of the many surfaces provides more places for creosote and fly ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to periodically inspect your catalyst for signs of blockage Masking and Poisoning While the catalyst itself does not enter into the combus tion process it is possible for certain elements such as lead and sulfur ...

Страница 21: ...tem Description Part Number Item Description Part Number 1 Bottom 1301332 2 Bottom Leg 1301341 3 Shadow Tray 1301321 4 Air Valve Primary 1601570 5 Clip Glass 1601396 6 Right Side 1301317 7 Left Side 1301318 8 Primary Air Cover 1301324 9 Back 1301328 10 Catalyst Block 30001153 11 Refractory Assembly 1602527 12 Throat Hood 30001649 13 Fiberglass Gasket 1203588 14 Wedge 1301340 15 Catalyst Fireback 1...

Страница 22: ...Gasket 5 16 Adhesive Backed 1203591 59 Door Handle Assy 30002717 60 Door Handle Pawl Assy 5004025 61 Access Plug 1602516 62 Shield Primary Air 30002433 For parts and information about your insert contact your Vermont Castings authorized dealer For the name of the dealer nearest you contact CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 525 1898 Shell Enamel Parts Winte...

Страница 23: ...Date of failure of catalyst 4 Any relevant information or circumstances regarding determi nation of failure 5 In addition the owner must return the failed catalyst Exclusions Limitations 1 This warranty is transferable however proof of original retail purchase is required 2 This warranty does not cover misuse of the stove Misuse includes overfiring which will result if the stove is used in such a m...

Страница 24: ... CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation ...

Отзывы: