39

WDV See-thru Gas Fireplace

Safety Features

1.  Low Battery Detection 
  When low battery condition occurs, the transmitter will 

turn off the fireplace. 
A) Battery voltage is checked every one min-

ute.  When  the  battery  voltage  is  low,  the 

LCD displays a low battery icon which will 

exist in all modes.

B) The  transmitter  will  not  operate  with  low 

battery  voltage.  Change  the  batteries  be-

fore the batteries become too weak for normal op-

erations.  

2.  Power On Initialization
  After the power-on initialization, the transmitter sends 

a signal to turn off the fireplace.

3.  Thermal Shutdown
  When the ambient temperature is more than 99°F, the 

transmitter will turn off the fireplace. 
A) The LCD will display “HI”. 
B) The Transmitter  will  not  function  until 

the room temperature has dropped be-

low 99 degree Fahrenheit. 

4.  Low Temperature Condition
  When  the  ambient  temperature  is  less 

than  40  degrees  Fahrenheit,  the  LCD 

will  display  “LO”,  and  NO  SIGNAL  will 

be sent to turn on the appliance.

  All  functions  still  remain  the  same  for 

both  Manual  Mode  and  Thermostat 

Mode

5.  Child-proof Protection 
  The child-proof icon will be shown when 

the  child-proof  mode  is  activated  by 

pressing  the  ON  button  and  the  OFF 

button  at  the  same  time  for  three  sec-

onds.
A) Enter childproof mode by pressing and holding both 

the ON button and the OFF button simultaneous-

ly  for  3  seconds.  The  Childproof  indicator  will  be 

shown on the LCD.  

B) Deactivate childproof mode by pressing and hold-

ing the ON button and the OFF button simultane-

ously for 3 seconds again. The Childproof indicator 

disappears on the LCD.  

C) The  transmitter  cannot  be  operated  in  childproof 

mode.

TOuch Screen reMOTe cOnTrOl OperaTIOn

tons become flame height controller again.

5.  When the light button is flashing, slide up and down on 

the arrow buttons will turn the light brightness to HIGH 

or Off directly without pressing the light button again to 

confirm

aux control (Optional)

The AUX control function is used to turn on or 

turn off the auxiliary component connected to the 

AC module of the Signature Command System. 

Press the AUX button to turn on or turn off the 

auxiliary.
1.  When the auxiliary is turned on, the icon will become 

solid  text  and  the  “ON”  icon  will  appear  below  the 

“AUX” icon.

2.  When the auxiliary is turned off, the icon will become 

hollow text and the “ON” icon will disappear.

nOTe:

 Some fireplaces use the AUX function to control 

options within the fireplace. Refer to fireplace manual for 

operation.

Setting up Blank Screen or constant Display in Idle

Figure 53

There is an option to 

set  up  how  the  LCD 

displays  and  func-

tions when the trans-

mitter is in idle. There 

are two choices: 
1.  A)  Mode.  When 

the  transmitter  is 

in  idle,  the  icons 

in the “touch area” 

(timer, thermostat, 

blower,  light  and 

AUX)  will  disap-

pear, as shown in the figure on the left. When any of 

the touch buttons is pressed, those icons will appear 

and are ready to operate (default). 

2.  B) Mode. The transmitter always displays all available 

icons  showing  current  status  of  timer,    thermostat, 

blower, light and AUX as shown in the figure on the 

right.

Press TIMER and THERMO buttons at the same time for 

3 seconds to toggle between A) and B). 

1.  When the current setting is A), touch any place in the 

touch area to bring up the icons then press TIMER but-

ton and THERMO button at the same time for 3 sec-

onds. The backlight will flash once to indicate that the 

setting has changed to B).

2.  When the current setting is B), pressing TIMER button 

and THERMO button at the same time for 3 seconds 

will switch to A) Mode. The touch area icons will disap-

pear.

FP2658
AUX

FP2612
low battery

FP2613
HI

FP2614
lo no child

FP2659
blank screen

Figure 53

Содержание WDVST500

Страница 1: ...manual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home...

Страница 2: ...Wiring 25 Command Center Wall Installation 25 Wall Switch Installation 25 SCS Wiring Diagram 26 Thank you and congratulations on your purchase of a Vermont Castings Group Fireplace PLEASE READ THE IN...

Страница 3: ...d by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with h...

Страница 4: ...Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for V...

Страница 5: ...any damage is found Do not install any unit with damaged incomplete or substitute parts Check your packing list to verify that all listed parts have been received You should have the following Firepla...

Страница 6: ...Failure to do so will cause fire and damage to property 1 2 or 5 8 25 6M 654 mm Min Rough Opening Width 51 6M 1314 mm 40 1016 mm 3656 918 mm 17 6 454 mm 29 6QE 751 mm 37 6 956 mm 7556QE 195 mm 156O 38...

Страница 7: ...his manual for allowable venting configurations These units can be installed in a bedroom Refer to the National Fuel Gas Code ANSI Z233 1 NFPA 54 cur rent edition the Uniform Mechanical Code current e...

Страница 8: ...hazard The appliance cannot be installed on a carpet tile or other combustible material other than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wo...

Страница 9: ...brick tile slate steel or other materials with a UL fire rating of Zero may be used to cover the black painted face of the appliance It is permissible to bring combustible wall board to the top of the...

Страница 10: ...m 1 25 mm Figure 7 Combustible Clearances for Vent Pipe 12 305 mm Vertical Rise Required Before Horizontal Run FP2748 Venting INSTALLATION INFORMATION Read all instructions completely and thoroughly b...

Страница 11: ...Treatment of firestops and construction of the chase may vary from building type to building type These instructions are not substitutes for the requirements of local building codes You must follow a...

Страница 12: ...the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000...

Страница 13: ...he pipe on the fireplace Vertical Dimension From the Floor of Unit to the Center of the Horizontal Vent Pipe Dimensions in Feet 50 1270 mm From Floor to Center Outside Corner Inside Corner Termination...

Страница 14: ...into position Measure the vertical height X required from the base of the flue collars to the center of the wall opening Figure 12 Step 4 Using appropriate length of pipe section s attach to fire plac...

Страница 15: ...installation is three 3 Figure 14 A minimum of 12 305 mm is required before a 90 elbow If a 90 elbow is fitted directly after 12 305 mm vertical section mounted to the top of the fireplace the maximu...

Страница 16: ...he exterior wall See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 12 1 Establish vent hole through the wall 2 Remove soil to a depth of approximately 16 below base of...

Страница 17: ...d Pipe Sheet Metal Screws Wall Screws Snorkel WARNING Do not back fill around snorkel A clearance of at least 4 must be maintained between the snorkel and the soil Up to two 45 elbows may be used with...

Страница 18: ...g to the position of the flue exit Mark the center point where the vent will penetrate the ceiling Drill a small locating hole a this point Drop a plumb line from the inside of the roof to the ceiling...

Страница 19: ...o combustible materials 6 Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements NOTE You must increase vent height for steep roof pitches Nearby t...

Страница 20: ...Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter collar for a minimum 1C v overlap 5 Locate the clamp at approximately 3 4 from the flex end and tighten 6 Secure the cla...

Страница 21: ...are to be installed at inter vals prescribed by the flexible vent manufacturer and in such a way as to maintain concentric inner and outer vent spacing D Attaching flexible venting to vertical termin...

Страница 22: ...r sleet When using copper of flex connectors use only fittings approved for gas connections The gas control inlet is 3 8 NPT The gas control is equipped with a captured screw type pressure test point...

Страница 23: ...of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed upstream of the appliance Figure 32 CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP ga...

Страница 24: ...lectrical Wiring General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The A C module plugs into the fireplace junction box A C power supply Four 4 AA batteri...

Страница 25: ...ot extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction...

Страница 26: ...Command Center Optional Wall Switch Plug in Connector Stepper Motor to Control Board DC Power Green Ground Plug in Connector Control Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve Light 300...

Страница 27: ...rectly WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical power supply or...

Страница 28: ...fastening the eight 8 screws securing the front and sides 2 Install the six 6 halogen light bulbs provided Do not touch light bulbs directly with fingers 3 Replace the front floor screen frame Be sure...

Страница 29: ...t Firebox Perimeter Burner Surface Rear Vent FP2434 Example of Stone Placement FP2702 rock and stone place FP2743 GLASS ONLY PLACEMENT NOTE Two 2 bags of glass are supplied with the 500 Series firepla...

Страница 30: ...phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not...

Страница 31: ...gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will l...

Страница 32: ...ut X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower Modulation X Three Brightness Settings for Lights X Three S...

Страница 33: ...ds when the master switch Shutoff on the main burner is off RF Remote Receiver Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Learn Remot...

Страница 34: ...anual reset Self Diagnostics Chart The Command Center has a self diagnostic LED en abling you to troubleshoot problems and potentially avoid a service call Please refer to the charts below for indicat...

Страница 35: ...an extended period of time Never leave anything on top of the surface of the transmitter FP2646 TSFSC display Information Bar Touch Area Logo Bar Menus Adjustment Controls Function Areas of the LCD D...

Страница 36: ...he Command Cen ter will flash for 10 seconds WARNING Do not use two 2 or more remote control sys tems in the same area with the same privacy code setting as they will communicate with each other This...

Страница 37: ...it Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero Or c Slide down on the arrow buttons to exit TIMER mode and shut off the fir...

Страница 38: ...ill remember this setting and the blower is still off see blower On Delay and Off Delay in the next section 4 After the signal is sent the ON up and OFF down but tons become flame height controller ag...

Страница 39: ...n the light button is flashing slide up and down on the arrow buttons will turn the light brightness to HIGH or Off directly without pressing the light button again to confirm AUX Control Optional The...

Страница 40: ...atteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The transmitter did not match 1 Make sure the transmitter has wi...

Страница 41: ...ce a year Make sure the burner porting pilot air opening and burner air opening are free of obstructions at all times Pilot Flame The flames from the pilot should be visually checked as soon as the he...

Страница 42: ...cement glass door assemblies MUST be supplied by the fireplace manufacturer No substitute materi als may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clea...

Страница 43: ...h Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check v...

Страница 44: ...0 Watt 12 20301100 2 Bulb Socket 12 73D4521K 3 Glass Frame Assembly 2 78D0027K 4 Junction Box Assembly not shown 1 26D2128 5 Panel Access Door 2 78D0040K Accessories Field Installed Options 6 Porcelai...

Страница 45: ...78D2082 45 WDV See thru Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 780012 DVW SG parts 6 09 1 2 3 4 15 5 6 7 8a 9 14 8b...

Страница 46: ...w Shutoff Valve 1 69D0030 69D0030 7 Injector 2 59D0062 69D0226 8a Burner Assembly 1 78D2100 78D2100 8b Burner Assembly 1 78D2101 78D2101 9 Venturi 2 69D1026 69D1026 10 Air Shutter not shown 2 69D1027...

Страница 47: ...tones REPLACEMENT PARTS Item Description 500 Qty 600 Qty Part No 1 White Stone 1 5 5 78D0122 2 Light Gray Stone 2 5 5 78D0123 3 Dark Gray Stone 3 5 10 78D0124 4 Brown Stone 4 5 5 78D0125 5 Sand Stone...

Страница 48: ...48 78D2082 WDV See thru Gas Fireplace HOT 1 2 3 4 5 6 9 7 8 10 730024 KHLDV vent parts VENT components REPLACEMENT PARTS...

Страница 49: ...D6 3 4 9 Pipe Length 58DVA 09 1207 5DT 09 3 4 12 Pipe Length 58DVA 12 1206 5DT 12 5D12 3 4 24 Pipe Length 58DVA 24 1204 5DT 24 5D24 3 4 36 Pipe Length 58DVA 36 1203 5DT 36 5D36 3 4 48 Pipe Length 58DV...

Страница 50: ...ordance with the above provisions shall comply with NFPA 720 and ANSI UL 2034 listed and IAS certified Signage A metal or plastic identification plate shall be permanently mounted to the exterior of t...

Страница 51: ...Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner...

Страница 52: ...n CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency WDVST500NTSC 61 0 WDVST500PTSC 59 7 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgr...