background image

78D2082

3

WDV See-thru Gas Fireplace

4.   Never install the fireplace 

•  

in a recreational vehicle

•  

where curtains, furniture, clothing, or other flam-

mable objects are less than 42" from the front, top, 

or sides of the fireplace

•  

in high traffic areas

•  

in windy or drafty areas 

5.  This fireplace reaches high temperatures. Keep chil-

dren and adults away from hot surfaces to avoid burns 

or clothing ignition. Fireplace will remain hot for a time 

after shutdown. Allow surfaces to cool before touch-

ing. 

6.  Carefully supervise young children when they are in 

the room with fireplace. 

7.  Do not modify fireplace under any circumstances. Any 

parts removed for servicing must be replaced prior to 

operating fireplace. 

8.  Turn fireplace off and let cool before servicing, install-

ing, or repairing. Only a qualified service person should 

install,  service,  or  repair  the  fireplace.  Have  burner 

system  inspected  annually  by  a  qualified  service 

person. 

9.  You must keep control compartments, burners, and 

circulating air passages clean. More frequent clean-

ing  may  be  needed  due  to  excessive  lint  and  dust. 

Turn off the gas valve and pilot light before cleaning 

fireplace. 

10. Have venting system inspected annually by a quali-

fied service person. If needed, have venting system 

cleaned or repaired. Refer to 

Cleaning and Mainte-

nance

Page 41

11.  Keep the area around your fireplace clear of combus-

tible materials, gasoline, and other flammable vapor 

and liquids. Do not run fireplace where these are used 

or stored. Do not place items such as clothing or deco-

rations on or around fireplace. 

12.  Do not use this fireplace to cook food or burn paper or 

other objects.

13. Never place anything on top of fireplace.

IMpOrTanT SaFeTy InFOrMaTIOn

This fireplace is a vented product. This fireplace must be 

properly installed by a qualified service person. The glass 

door must be properly seated and sealed. If this unit is not 

properly installed by a qualified service person with glass 

door  properly  seated  and  sealed,  combustion  leakage 

can occur. 

carBOn MOnOxIDe pOISOnInG:

 Early signs of carbon 

monoxide poisoning are similar to the flu with headaches, 

dizziness and/or nausea. If you have these signs, the fire-

place may not have been installed properly. Get fresh air 

at once! Have the fireplace inspected and serviced by a 

qualified service person. Some people are more affected 

by carbon monoxide than others. These include pregnant 

women,  people  with  heart  or  lung  disease  or  anemia, 

those under the influence of alcohol, and those at high 

altitudes. 
Propane/LP  gas  and  natural  gas  are  both  odorless. An 

odor-making agent is added to each of these gases. The 

odor helps you detect a gas leak. However, the odor added 

to these gases can fade. Gas may be present even though 

no odor exists.
Make certain you read and understand all warnings. Keep 

this manual for reference. It is your guide to safe and proper 

operation of this fireplace.
1.  This  appliance  is  only  for  use  with  the  type  of  gas 

indicated  on  the  rating  plate. This  appliance  is  not 

convertible for use with other gases unless a certified 

kit is used. 

2.  For  propane/LP  fireplace,  do  not  place  propane/LP 

supply tank(s) inside any structure. Locate propane/

LP supply tank(s) outdoors. To prevent performance 

problems, do not use propane/LP fuel tank of less than 

100 lbs. capacity. 

3.  If you smell gas

•  

shut off gas supply.

•  

do not try to light any appliance.

•  

do not touch any electrical switch; do not use any 

phone in your building .

•  

immediately call your gas supplier from a neigh-

bor’s  phone.  Follow  the  gas  supplier’s  instruc-

tions.

InSTaller

Please leave these instructions with the appliance.

OWner

Please retain these instructions for future reference.

• 

read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this fireplace. 

• 

any change to this fireplace or its controls can be dangerous.

• 

Improper installation or use of this fireplace can cause serious injury or death from 

fire, burns, explosions, electrical shock and carbon monoxide poisoning.

W

arn

In

G

Содержание WDVST500

Страница 1: ...manual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home...

Страница 2: ...Wiring 25 Command Center Wall Installation 25 Wall Switch Installation 25 SCS Wiring Diagram 26 Thank you and congratulations on your purchase of a Vermont Castings Group Fireplace PLEASE READ THE IN...

Страница 3: ...d by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with h...

Страница 4: ...Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for V...

Страница 5: ...any damage is found Do not install any unit with damaged incomplete or substitute parts Check your packing list to verify that all listed parts have been received You should have the following Firepla...

Страница 6: ...Failure to do so will cause fire and damage to property 1 2 or 5 8 25 6M 654 mm Min Rough Opening Width 51 6M 1314 mm 40 1016 mm 3656 918 mm 17 6 454 mm 29 6QE 751 mm 37 6 956 mm 7556QE 195 mm 156O 38...

Страница 7: ...his manual for allowable venting configurations These units can be installed in a bedroom Refer to the National Fuel Gas Code ANSI Z233 1 NFPA 54 cur rent edition the Uniform Mechanical Code current e...

Страница 8: ...hazard The appliance cannot be installed on a carpet tile or other combustible material other than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wo...

Страница 9: ...brick tile slate steel or other materials with a UL fire rating of Zero may be used to cover the black painted face of the appliance It is permissible to bring combustible wall board to the top of the...

Страница 10: ...m 1 25 mm Figure 7 Combustible Clearances for Vent Pipe 12 305 mm Vertical Rise Required Before Horizontal Run FP2748 Venting INSTALLATION INFORMATION Read all instructions completely and thoroughly b...

Страница 11: ...Treatment of firestops and construction of the chase may vary from building type to building type These instructions are not substitutes for the requirements of local building codes You must follow a...

Страница 12: ...the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000...

Страница 13: ...he pipe on the fireplace Vertical Dimension From the Floor of Unit to the Center of the Horizontal Vent Pipe Dimensions in Feet 50 1270 mm From Floor to Center Outside Corner Inside Corner Termination...

Страница 14: ...into position Measure the vertical height X required from the base of the flue collars to the center of the wall opening Figure 12 Step 4 Using appropriate length of pipe section s attach to fire plac...

Страница 15: ...installation is three 3 Figure 14 A minimum of 12 305 mm is required before a 90 elbow If a 90 elbow is fitted directly after 12 305 mm vertical section mounted to the top of the fireplace the maximu...

Страница 16: ...he exterior wall See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 12 1 Establish vent hole through the wall 2 Remove soil to a depth of approximately 16 below base of...

Страница 17: ...d Pipe Sheet Metal Screws Wall Screws Snorkel WARNING Do not back fill around snorkel A clearance of at least 4 must be maintained between the snorkel and the soil Up to two 45 elbows may be used with...

Страница 18: ...g to the position of the flue exit Mark the center point where the vent will penetrate the ceiling Drill a small locating hole a this point Drop a plumb line from the inside of the roof to the ceiling...

Страница 19: ...o combustible materials 6 Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements NOTE You must increase vent height for steep roof pitches Nearby t...

Страница 20: ...Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter collar for a minimum 1C v overlap 5 Locate the clamp at approximately 3 4 from the flex end and tighten 6 Secure the cla...

Страница 21: ...are to be installed at inter vals prescribed by the flexible vent manufacturer and in such a way as to maintain concentric inner and outer vent spacing D Attaching flexible venting to vertical termin...

Страница 22: ...r sleet When using copper of flex connectors use only fittings approved for gas connections The gas control inlet is 3 8 NPT The gas control is equipped with a captured screw type pressure test point...

Страница 23: ...of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed upstream of the appliance Figure 32 CAUTION Use pipe joint sealant that is resistant to liquid petroleum LP ga...

Страница 24: ...lectrical Wiring General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The A C module plugs into the fireplace junction box A C power supply Four 4 AA batteri...

Страница 25: ...ot extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction...

Страница 26: ...Command Center Optional Wall Switch Plug in Connector Stepper Motor to Control Board DC Power Green Ground Plug in Connector Control Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve Light 300...

Страница 27: ...rectly WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical power supply or...

Страница 28: ...fastening the eight 8 screws securing the front and sides 2 Install the six 6 halogen light bulbs provided Do not touch light bulbs directly with fingers 3 Replace the front floor screen frame Be sure...

Страница 29: ...t Firebox Perimeter Burner Surface Rear Vent FP2434 Example of Stone Placement FP2702 rock and stone place FP2743 GLASS ONLY PLACEMENT NOTE Two 2 bags of glass are supplied with the 500 Series firepla...

Страница 30: ...phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not...

Страница 31: ...gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will l...

Страница 32: ...ut X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower Modulation X Three Brightness Settings for Lights X Three S...

Страница 33: ...ds when the master switch Shutoff on the main burner is off RF Remote Receiver Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Learn Remot...

Страница 34: ...anual reset Self Diagnostics Chart The Command Center has a self diagnostic LED en abling you to troubleshoot problems and potentially avoid a service call Please refer to the charts below for indicat...

Страница 35: ...an extended period of time Never leave anything on top of the surface of the transmitter FP2646 TSFSC display Information Bar Touch Area Logo Bar Menus Adjustment Controls Function Areas of the LCD D...

Страница 36: ...he Command Cen ter will flash for 10 seconds WARNING Do not use two 2 or more remote control sys tems in the same area with the same privacy code setting as they will communicate with each other This...

Страница 37: ...it Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero Or c Slide down on the arrow buttons to exit TIMER mode and shut off the fir...

Страница 38: ...ill remember this setting and the blower is still off see blower On Delay and Off Delay in the next section 4 After the signal is sent the ON up and OFF down but tons become flame height controller ag...

Страница 39: ...n the light button is flashing slide up and down on the arrow buttons will turn the light brightness to HIGH or Off directly without pressing the light button again to confirm AUX Control Optional The...

Страница 40: ...atteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The transmitter did not match 1 Make sure the transmitter has wi...

Страница 41: ...ce a year Make sure the burner porting pilot air opening and burner air opening are free of obstructions at all times Pilot Flame The flames from the pilot should be visually checked as soon as the he...

Страница 42: ...cement glass door assemblies MUST be supplied by the fireplace manufacturer No substitute materi als may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clea...

Страница 43: ...h Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check v...

Страница 44: ...0 Watt 12 20301100 2 Bulb Socket 12 73D4521K 3 Glass Frame Assembly 2 78D0027K 4 Junction Box Assembly not shown 1 26D2128 5 Panel Access Door 2 78D0040K Accessories Field Installed Options 6 Porcelai...

Страница 45: ...78D2082 45 WDV See thru Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 780012 DVW SG parts 6 09 1 2 3 4 15 5 6 7 8a 9 14 8b...

Страница 46: ...w Shutoff Valve 1 69D0030 69D0030 7 Injector 2 59D0062 69D0226 8a Burner Assembly 1 78D2100 78D2100 8b Burner Assembly 1 78D2101 78D2101 9 Venturi 2 69D1026 69D1026 10 Air Shutter not shown 2 69D1027...

Страница 47: ...tones REPLACEMENT PARTS Item Description 500 Qty 600 Qty Part No 1 White Stone 1 5 5 78D0122 2 Light Gray Stone 2 5 5 78D0123 3 Dark Gray Stone 3 5 10 78D0124 4 Brown Stone 4 5 5 78D0125 5 Sand Stone...

Страница 48: ...48 78D2082 WDV See thru Gas Fireplace HOT 1 2 3 4 5 6 9 7 8 10 730024 KHLDV vent parts VENT components REPLACEMENT PARTS...

Страница 49: ...D6 3 4 9 Pipe Length 58DVA 09 1207 5DT 09 3 4 12 Pipe Length 58DVA 12 1206 5DT 12 5D12 3 4 24 Pipe Length 58DVA 24 1204 5DT 24 5D24 3 4 36 Pipe Length 58DVA 36 1203 5DT 36 5D36 3 4 48 Pipe Length 58DV...

Страница 50: ...ordance with the above provisions shall comply with NFPA 720 and ANSI UL 2034 listed and IAS certified Signage A metal or plastic identification plate shall be permanently mounted to the exterior of t...

Страница 51: ...Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner...

Страница 52: ...n CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency WDVST500NTSC 61 0 WDVST500PTSC 59 7 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgr...