background image

Clean Face Direct Vent 

Fireplace Insert

Models: VC41LDVINTSC, 

VC41LDVIPTSC, VC41CDVINTSC

20304685  11/13  Rev. 4

Installation and 

Operating Instructions

WARNING

IF The INFORMATION IN TheSe INSTRuCTIONS IS 

NOT FOLLOWeD exACTLy, A FIRe OR exPLOSION 

MAy  ReSuLT  CAuSING  PROPeRTy  DAMAGe, 

PeRSONAL INjuRy OR LOSS OF LIFe.

– 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

–  WhAT TO DO IF yOu SMeLL GAS
 

•  Do not try to light any appliance.

 

•  Do not touch any electrical switch; do not use 

any phone in your building.

 

•  Immediately  call  your  gas  supplier  from  a 

neighbor's phone. Follow the gas supplier's 

instructions.

 

•  If you cannot reach your gas supplier, call the 

fire department.

–  Installation  and  service  must  be  performed 

by a qualified installer, service agency or the 

gas supplier.

WARNING:  Improper  installation,  adjustment, 

alteration,  services  or  maintenance  can  cause 

injury  or  property  damage.  Refer  to  this  manual. 

For  assistance  or  additional  information  consult 

a  qualified  installer,  service  agency  or  the 

gas supplier.   

This appliance may be installed in an aftermarket*, 

permanently  located,  manufactured  home  (uSA 

only)  or  mobile  home,  where  not  prohibited  by 

local codes.

This appliance is only for use with the type of gas 

indicated  on  the  rating  plate.  This  appliance  is 

not convertible for use with other gases, unless a 

certified kit is used. 

*  Aftermarket:  Completion  of  sale,  not  for  purpose  of  resale, 

from the manufacturer.

INSTALLeR: Leave this manual with the appliance.
CONSuMeR: Retain this manual for future refer-

ence.

4685
VC41LDVI insert cover

WARNING

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

Un panneau vitré chaud

 peut 

causer des brûlures.

Laissez refroidir le panneau

vitr

é

 avant d’y toucher.

Ne laisser jamais

 les enfants

toucher le panneau vitr

é

.

AVERTISSEMENT

Содержание VC41CDVINTSC

Страница 1: ...G Improper installation adjustment alteration services or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer se...

Страница 2: ...as Shutoff Tool 19 Electrical Installation 20 Electrical Wiring 20 Log Placement 21 Decorative Glass Installation 24 Bead Placement 24 Stone Placement 25 Operating Instructions 26 For Your Safety Read...

Страница 3: ...installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the fl...

Страница 4: ...from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Cana...

Страница 5: ...rtified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installation must be in accordance with the current ANSI Z223 1 NFPA 54...

Страница 6: ...ireplace Insert insert dimensions Figure 2 VC41LDVI Fireplace Insert Dimensions 24 6QE 621 mm 1356M 337 mm 1256O 318 mm 2 6QE 56 mm 55 6QE 144 mm 1856 460 mm 26 6QE 668 mm 2956 740 mm 256M 57 mm 2356Q...

Страница 7: ...specific installation requirements IMPORTANT Your direct vent insert was designed to be installed in an existing wood burning fireplace The location and clearances are subject to local building codes...

Страница 8: ...it is considered a mantel and must meet the mantel requirements listed in this manual FP2988 Figure 3 Mantel Clearances NOTE Side clearance to combustibles is 10 254 mm from opening whether it is sid...

Страница 9: ...AND CENTER BRACKET In order to fit insert into a smaller opening the command center bracket may be removed Refer to Pages 6 and 9 for dimensions If the bracket is removed the small 2 deep three sided...

Страница 10: ...well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during this time Fp...

Страница 11: ...ore attempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and maintained venting system could result in serious inju...

Страница 12: ...d to resize orifice for use at high altitude contact your dealer High Temp Silicone FP2948 exhaust pipe 3 and 3 UL 1777 Gas Liner Apply high temperature silicone to lines on both ends and secure with...

Страница 13: ...let Recommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box Figure 11 Inlet and Exhaust Reline NOTE You may use a reline configuration...

Страница 14: ...els and retainers from packaging 2 Remove two 2 screws on each side of front edge of chamber 3 Install one 1 front brick retainer bracket on each side with the screws removed in Step 2 4 Carefully set...

Страница 15: ...celain Panel Kit Contemporary Porcelain Panel Kit Contemporary Support Bracket Supplied w Contem porary Kit Use Self tapping Screws Existing Support Figure 14 1 Remove porcelain panels and hardware fr...

Страница 16: ...e closed Retighten screws NOTE For propane LP units the baffle assembly is com pletely removed for venting under 20 ft 6 m For venting 20 ft and above the baffle assembly is to be used with only one 1...

Страница 17: ...ou must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regula tor damage could occur Install external regulator with the ven...

Страница 18: ...contaminants This keeps them from going into the burner system gas con trols If sediment trap drip leg is not installed or is installed wrong burner system may not run properly NOTE The gas line conn...

Страница 19: ...ater and soap solution or a gas sniffer 4 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high F...

Страница 20: ...electrical supply Electricity is only needed to operate blower Verify proper operation after servicing Electrical connections should only be performed by a qualified licensed electrician Main power mu...

Страница 21: ...rs may be added to entire burner area in front of grate to hide burner and log support brackets Figure 23 Ember Material Area The positioning of the logs is critical to the safe and clean operation of...

Страница 22: ...pport bracket Figure 24 Figure 25 4 Install log 2 by placing locator block between front and rear burner Place notch in bottom of log on the back end of the 2nd from left grate tine Figure 25 Log 3 LG...

Страница 23: ...g 5 by placing rectangu lar notch on the bottom of the log onto the rectangular protrusion in the center of log 1 Place the front of log 5 onto the grate bar to the right of the center grate tine Push...

Страница 24: ...d with unit 2 Mix the two 2 bags of decorative glass provided in the kit as desired Lay glass on top of burner and cover burner area with one 1 layer Glass may be used around the perimeter next to the...

Страница 25: ...Lay glass on top of burner and cover burner area with one 1 layer Glass may be used around the perimeter next to the wall Make sure glass is not blocking gaps between perimeter bracket and the burner...

Страница 26: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not fun...

Страница 27: ...s go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will lig...

Страница 28: ...de and rear brick panels 2 Remove log support bracket by removing two 2 screws in rear and one 1 screw on each side wall FP1940 air shutter part open Air Shutter FP1940 Figure 32 Push Adjustment Lip U...

Страница 29: ...just below the horizontal grate bar The slide adjustable air shutter has a range of 1 Figure 34 To increase air mixture open the slide adjustment by gently pulling on the lever When lever stops it ha...

Страница 30: ...X Low battery Indication for Transmitter X Child Proof Lock out X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blowe...

Страница 31: ...3 seconds when the master switch Shutoff on the main burner is off RF Remote Receiver Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Lear...

Страница 32: ...Learning GREEN Flashes every 1 sec for 10 sec AC Power On GREEN solid Pressure Switch Failed Power Vent only One RED every 2 sec until manual reset Self Diagnostics Chart The Command Center has a self...

Страница 33: ...arrows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT FAN and AUX Rear Burner Control The adjustment arrows include ON up...

Страница 34: ...on the Command Cen ter will flash for 10 seconds 4 During the 10 sec onds press the OFF button on the transmitter to learn Another two beeps will be given to confirm a success ful learning Figure 40 T...

Страница 35: ...ireplace will be shut down completely when the timer counts down to zero 6 To exit Timer Mode a Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to z...

Страница 36: ...d OFF down button to increase de crease the blower speed 3 Press the fan button again to confirm the speed set ting If the fireplace is on the blower speed will take effect right away if the fireplace...

Страница 37: ...ng is A touch any place in the touch area to bring up the icons then press TIMER but ton and THERMO button at the same time for 3 sec onds The backlight will flash once to indicate that the setting ha...

Страница 38: ...play is blank 2 Check battery installation or replace batteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The trans...

Страница 39: ...not use abrasive cleaners They will damage the glass surface pilot and burner flames Visually check pilot and burner flames periodically Refer to Figure 50 for typical burner flame Refer to Figure 51...

Страница 40: ...Contact dealer where you bought heater 4 Remove rock wool Clean burner and burner ports Figure 53 5 Replace log set and ember according to instructions on Pages 21 25 Replace decorative glass accordi...

Страница 41: ...through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery C...

Страница 42: ...20304685 VC41LDVI VC41CDVI Gas Fireplace Insert REPLACEMENT PARTS 24 6 1 2 3 4 5 11 12 14 16 39 32 34 33 38 4685 VC41LDVI parts 17 27 25 26 31 30 29 10 7 8 9 13 15 18 19 20 21 22 11 19 23 40 47 48 8...

Страница 43: ...nd Center SCS 1 80D0005 80D0005 80D0005 27 AC Module SCS 1 80D0004 80D0004 80D0004 28 Remote Control 1 TSFRSC TSFRSC TSFSC 29 Wire Valve Control Board SCS 1 80D0010 80D0010 80D0010 30 Wire CC CB 24 SC...

Страница 44: ...nversion Kits Natural Gas to LP VC41LDVINTSC Kit 40ICFPGK VC41CDVINTSC Kit ICF40LPK WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically ap...

Страница 45: ...TVI 5b Glass Frame Textured Mocha ICF40GTTM 6a Rectangular Double Door Satin Black ICF40R2DSB 6b Rectangular Double Door Vintage Iron ICF40R2DVI 6c Rectangular Double Door Textured Mocha ICF40R2DTM 7a...

Страница 46: ...comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Plea...

Страница 47: ...ited 10 year warranty will be void if the appliance is not installed by a qualified installer in accor dance with the installation instructions The limited 10 year warranty will also be void if the ap...

Страница 48: ...ndement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings D O E Fireplace Efficiency AFUE VC41LDVINTSC 75 8 70 67 VC41LDVIPTSC 78 9 71 26 VC41CDVINTSC 7...

Отзывы: