background image

9

3311956

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these directions exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electrical switch, do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department

Lighting Instructions

1. Turn the gas shut-off valve to OFF.

2. Wait five (5) minutes to clear out any gas. If you

then smell gas STOP! Follow the safety information
on above. If you do not smell gas, go on to the next
step.

3. Light a match and lay it on top of the pan material,

about 2” from the end of the supply side of the pan.
(Fig. 8)

4. Slowly turn the gas shut-off valve ON until the

burner ignites. If the burner does not ignite within
ten (10) seconds with the match burning, turn the
shut-off valve OFF and repeat steps 1 through 4
again.

WARNING: Flame may flare up when ignited. Keep hands and face away from firebox.

Operation and Maintenance

To Adjust the Flame:

Adjust the flame to the desired level by rotating the gas
valve counterclockwise 

  to open or clockwise

  to close.

To Turn the Appliance OFF:

Rotate the gas shut-off valve clockwise 

  to OFF.

Proper Maintenance:

Keep the area around the log set clean and clear of
debris.

Occasionally, you may use a soft bristle brush to clean
logs.

Once every year, a qualified agency or certified chim-
ney sweep should examine and clean the venting
system of the fireplace in which the log set is installed.

Appliance Break-In

During the 2-3 hour appliance break-in period, you may
detect an odor from the appliance as the various water-
based paints used in the manufacture of this log set
cure. This is a normal and temporary situation that is
not a cause for alarm. However, you may want to
provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

1. Ignite a 2” flame and maintain it  for 1/2 hour.

2. Burn the logs in  consecutive 1/2 hour periods,

raising the flame an additional 2” to full flame height
for a total of three hours.

Match

Figure 9

LG176

Содержание SR18SHK

Страница 1: ...st make adequate provision for accessibility and for combustion and ventilation of fresh air supply DANGER CARBON MONOXIDE POISONING MAY LEAD TO DEATH 3311956 12 04 Rev 5 Installation and Operating In...

Страница 2: ...lve immediately The cause of the venting problem must be discovered and corrected before using this gas log set Disregarding this warning can cause illness as well as soot damage to your fireplace roo...

Страница 3: ...n or other qualified installer must install one Have you checked local building codes Check with your local building department Does your fireplace have a wire mesh screen in place Pre Installation Ch...

Страница 4: ...is designed to work on all CFM Specialty Home Products BR BC SR SC TF and TL series fireplaces For all other fireplaces refer to Page 6 When installing a decorative gas appliance in a fireplace some l...

Страница 5: ...h an adjustable wrench Fig 3 If the Damper Stop does not fit drill a 1 4 hole into the damper plate and install an anchor bolt with nut at a 90 degree angle so that the damper plate will remain fully...

Страница 6: ...upply valve for no longer than 3 5 seconds If bubbles appear in the soap solution applied to the joints there is a leak Turn off gas supply valve and tighten those fittings Repeat the above procedure...

Страница 7: ...ogs The top logs can be arranged to achieve your desired flame pattern Be sure you leave as much open space between the logs as possible to minimize flame impingement and sooting 4 Open the bag of lav...

Страница 8: ...18 Standard Split Log Set LG333 24 Standard Split Log Set LG334 30 Standard Split Log Set LG335 18 Standard Combination Log Set LG336 24 Standard Combination Log Set LG337 30 Standard Combination Log...

Страница 9: ...1 through 4 again WARNING Flame may flare up when ignited Keep hands and face away from firebox Operation and Maintenance To Adjust the Flame Adjust the flame to the desired level by rotating the gas...

Страница 10: ...talled the correct orifice into the set Burner is Excessively Noisy Please Note The movement and combustion of gas will create low unavoidable levels of noise Excessive gas pressure Make sure the gas...

Страница 11: ...4 5 6a 6b 6c 6d 6e 2 6f 2 6 7a 7b 7c 7d 7e 7 8a 8b 8c 8d 8e 8f 8g 8 9a 9b 9c 9d 9e 2 9f 9g 9h 9j 9 CFM Specialty Home Products reserves the right to make changes in design materials specifications pr...

Страница 12: ...nt 20007700 2b 24 30 Round Right Front 20007701 2c 24 30 Back Log 20007702 2d 18 24 30 Cross Log 20007705 2e 24 30 Round Front Cross Log 20007704 2f 24 30 Cross Log 20007707 2g Top Log 2 per set 20008...

Страница 13: ...8 9b 30 Split Left Front 20007692 9c 18 24 30 Cross Log 20007699 9d Top Log 20008336 9e Top Log 2 per set 20008335 9f 24 30 Cross Log 20007707 9g 24 30 Round Front Cross Log 20007704 9h 18 24 30 Cross...

Страница 14: ...14 3311956...

Страница 15: ...anties specified in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Appliance including CFM Specialty Home Products supplied accessories and components...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings co CFM Specialty Home Products...

Отзывы: