background image

4

3311956

Tools Required

8” adjustable crescent wrench; pipe thread sealant compound or teflon tape; 12” pipe wrench or chan-
nel lock pliers.

Gas Plumbed on Left Hand Side of Fireplace

NOTE: Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas
on the right side (facing). If your fireplace is plumbed with the gas on the left side, you may remove the
u-burner tube from the burner pan by removing the 3/4” knockout at the left back of the burner pan and
reinstalling the u-burner tube 180 degrees from its original position. You may also run a flexible connec-
tor (or as per local codes) along the back wall of the fireplace to bring your gas line to the right hand
side. You can then place the set in front of the flexible connector.

Damper Stop Installation:

For Use with BR, BC, SR, SC, TF and TL Series CFM Specialty Home Products Fireplaces

This Damper Stop is designed to work on all CFM
Specialty Home Products BR, BC, SR, SC, TF and
TL series fireplaces. For all other fireplaces, refer
to Page 6.

When installing a decorative gas appliance in a
fireplace, some local codes require this Damper
Stop to be used so the Damper will not close
completely.  To install the Damper Stop:

The Damper Locking Bracket is already installed
on all BR, BC, SR, SC, TF and TL fireplaces.
Locate the Damper Locking Bracket on the left
side of the fireplace’s Combustion Dome. (Fig. 1)

With the Damper open, align the two slots on
either side of the cut-out on the Damper Stop with
the two small holes on the angled portion of the
Damper Locking Bracket.  Attach the Damper Stop
with the Screws provided, as shown in Figure 2.

NOTE: Some of the early fireplace units may not
have the holes in the end of the Damper Locking
Bracket.  If this is the case, use the Damper Stop
as a template to drill two (2) 1/8” holes in the
Damper Locking Bracket to mount the Damper
Stop.

Damper Locking Bracket

Damper Plate

DP100

Figure 1

Damper Locking
Bracket

Damper Stop Screw

Damper Stop

DP101

Figure 3

Содержание SR18SHK

Страница 1: ...st make adequate provision for accessibility and for combustion and ventilation of fresh air supply DANGER CARBON MONOXIDE POISONING MAY LEAD TO DEATH 3311956 12 04 Rev 5 Installation and Operating In...

Страница 2: ...lve immediately The cause of the venting problem must be discovered and corrected before using this gas log set Disregarding this warning can cause illness as well as soot damage to your fireplace roo...

Страница 3: ...n or other qualified installer must install one Have you checked local building codes Check with your local building department Does your fireplace have a wire mesh screen in place Pre Installation Ch...

Страница 4: ...is designed to work on all CFM Specialty Home Products BR BC SR SC TF and TL series fireplaces For all other fireplaces refer to Page 6 When installing a decorative gas appliance in a fireplace some l...

Страница 5: ...h an adjustable wrench Fig 3 If the Damper Stop does not fit drill a 1 4 hole into the damper plate and install an anchor bolt with nut at a 90 degree angle so that the damper plate will remain fully...

Страница 6: ...upply valve for no longer than 3 5 seconds If bubbles appear in the soap solution applied to the joints there is a leak Turn off gas supply valve and tighten those fittings Repeat the above procedure...

Страница 7: ...ogs The top logs can be arranged to achieve your desired flame pattern Be sure you leave as much open space between the logs as possible to minimize flame impingement and sooting 4 Open the bag of lav...

Страница 8: ...18 Standard Split Log Set LG333 24 Standard Split Log Set LG334 30 Standard Split Log Set LG335 18 Standard Combination Log Set LG336 24 Standard Combination Log Set LG337 30 Standard Combination Log...

Страница 9: ...1 through 4 again WARNING Flame may flare up when ignited Keep hands and face away from firebox Operation and Maintenance To Adjust the Flame Adjust the flame to the desired level by rotating the gas...

Страница 10: ...talled the correct orifice into the set Burner is Excessively Noisy Please Note The movement and combustion of gas will create low unavoidable levels of noise Excessive gas pressure Make sure the gas...

Страница 11: ...4 5 6a 6b 6c 6d 6e 2 6f 2 6 7a 7b 7c 7d 7e 7 8a 8b 8c 8d 8e 8f 8g 8 9a 9b 9c 9d 9e 2 9f 9g 9h 9j 9 CFM Specialty Home Products reserves the right to make changes in design materials specifications pr...

Страница 12: ...nt 20007700 2b 24 30 Round Right Front 20007701 2c 24 30 Back Log 20007702 2d 18 24 30 Cross Log 20007705 2e 24 30 Round Front Cross Log 20007704 2f 24 30 Cross Log 20007707 2g Top Log 2 per set 20008...

Страница 13: ...8 9b 30 Split Left Front 20007692 9c 18 24 30 Cross Log 20007699 9d Top Log 20008336 9e Top Log 2 per set 20008335 9f 24 30 Cross Log 20007707 9g 24 30 Round Front Cross Log 20007704 9h 18 24 30 Cross...

Страница 14: ...14 3311956...

Страница 15: ...anties specified in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Appliance including CFM Specialty Home Products supplied accessories and components...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings co CFM Specialty Home Products...