background image

2

3311956

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Read these directions thoroughly before installation. For assistance or additional information,
consult your gas log dealer, qualified installer, service agency or gas supplier.

WARNING

Do not use this appliance or any part that has
been under water. Immediately call a qualified
service technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been under water.

WARNING

If not installed, operated and maintained in
accordance with the manufacturer’s instruc-
tions, this product could expose you to sub-
stances in fuel or fuel combustion which are
known to the state of California to cause cancer,
birth defects or other reproductive harm.

WARNING

A properly sized, unobstructed chimney will normally vent all fumes and products of combustion. Any
odor or smoke detected in the room is an indication that the flue is not properly removing the combus-
tion products. Turn off the gas supply valve immediately! The cause of the venting problem must be
discovered and corrected before using this gas log set. Disregarding this warning can cause illness as
well as soot damage to your fireplace, room and furnishings.

WARNING

Young children are not allowed to operate this unit and must be supervised when they are in the same
room as the appliance.

Installation Precautions

Fireplace damper MUST be locked fully open when operating the gas log set.

If the fireplace has glass doors, operate gas log set only with doors fully opened. The fireplace screen
must be in place when the appliance is operating and, unless other provisions for combustion air are
provided, the screen shall have an opening(s) for introduction of combustion air.

The log set and its individual shut-off valve MUST be isolated from the gas supply piping system by
closing its individual shut-off valve during any pressure testing of gas supply at test pressures equal to
or less than 1/2 psig.

The log set and its individual shut-off valve MUST be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig.

Keep the gas log set clear and free from combustible materials, gasoline and other flammable vapors
and liquids.

Содержание SR18SHK

Страница 1: ...st make adequate provision for accessibility and for combustion and ventilation of fresh air supply DANGER CARBON MONOXIDE POISONING MAY LEAD TO DEATH 3311956 12 04 Rev 5 Installation and Operating In...

Страница 2: ...lve immediately The cause of the venting problem must be discovered and corrected before using this gas log set Disregarding this warning can cause illness as well as soot damage to your fireplace roo...

Страница 3: ...n or other qualified installer must install one Have you checked local building codes Check with your local building department Does your fireplace have a wire mesh screen in place Pre Installation Ch...

Страница 4: ...is designed to work on all CFM Specialty Home Products BR BC SR SC TF and TL series fireplaces For all other fireplaces refer to Page 6 When installing a decorative gas appliance in a fireplace some l...

Страница 5: ...h an adjustable wrench Fig 3 If the Damper Stop does not fit drill a 1 4 hole into the damper plate and install an anchor bolt with nut at a 90 degree angle so that the damper plate will remain fully...

Страница 6: ...upply valve for no longer than 3 5 seconds If bubbles appear in the soap solution applied to the joints there is a leak Turn off gas supply valve and tighten those fittings Repeat the above procedure...

Страница 7: ...ogs The top logs can be arranged to achieve your desired flame pattern Be sure you leave as much open space between the logs as possible to minimize flame impingement and sooting 4 Open the bag of lav...

Страница 8: ...18 Standard Split Log Set LG333 24 Standard Split Log Set LG334 30 Standard Split Log Set LG335 18 Standard Combination Log Set LG336 24 Standard Combination Log Set LG337 30 Standard Combination Log...

Страница 9: ...1 through 4 again WARNING Flame may flare up when ignited Keep hands and face away from firebox Operation and Maintenance To Adjust the Flame Adjust the flame to the desired level by rotating the gas...

Страница 10: ...talled the correct orifice into the set Burner is Excessively Noisy Please Note The movement and combustion of gas will create low unavoidable levels of noise Excessive gas pressure Make sure the gas...

Страница 11: ...4 5 6a 6b 6c 6d 6e 2 6f 2 6 7a 7b 7c 7d 7e 7 8a 8b 8c 8d 8e 8f 8g 8 9a 9b 9c 9d 9e 2 9f 9g 9h 9j 9 CFM Specialty Home Products reserves the right to make changes in design materials specifications pr...

Страница 12: ...nt 20007700 2b 24 30 Round Right Front 20007701 2c 24 30 Back Log 20007702 2d 18 24 30 Cross Log 20007705 2e 24 30 Round Front Cross Log 20007704 2f 24 30 Cross Log 20007707 2g Top Log 2 per set 20008...

Страница 13: ...8 9b 30 Split Left Front 20007692 9c 18 24 30 Cross Log 20007699 9d Top Log 20008336 9e Top Log 2 per set 20008335 9f 24 30 Cross Log 20007707 9g 24 30 Round Front Cross Log 20007704 9h 18 24 30 Cross...

Страница 14: ...14 3311956...

Страница 15: ...anties specified in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Appliance including CFM Specialty Home Products supplied accessories and components...

Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings co CFM Specialty Home Products...

Отзывы: