4
3311857
CAUTION:
If you answered “NO” to any item, or have any questions regarding your installation, please
contact your dealer/distributor for assistance.
Is the gas supply inlet pressure correct?
NG: Min. 5.5” w.c./Max. 14.0” w.c. LP: Min. 11” w.c./Max. 14.0” w.c.
Does the firebox meet the minimum size dimensions below?
Is your fireplace plumbed with gas on the right side (facing) of the fireplace?
If not, refer to ee Page 5
Is the gas supply line sized properly (Minimum 1/2” iron pipe)?
Do you have a solid fuel (wood burning) fireplace with a vented flue?
Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one.
Have you checked local building codes? (Check with your local building department)
Does your fireplace have a wire mesh screen in place?
Pre-Installation Checklist
Yes
No
Minimum Clearances & Specifications
Natural Gas Units
Propane Gas Units
Size
Btu/hr
Back
Front
Depth
Height
Size
Minimum
Maximum”
18”
45,000
16”
33”
15”
18”
51 sq.in.
5.5”w.c.
14.0”w.c.
3.5”w.c.
24”
60,000
20”
36”
15”
18”
51 sq.in.
5.5”w.c.
14.0”w.c.
3.5”w.c.
30”
60,000
27”
39”
15”
18”
51 sq.in.
5.5”w.c.
14.0”w.c.
3.5”w.c.
Minimum Firebox Dimensions
Minimum
Gas Fuel Line
Manifold
Set
Input
Width
Flue
Pressure
Pressure
Size
Btu/hr
Back
Front
Depth
Height
Size
Minimum
Maximum
18”
40,000
16”
33”
15”
18”
51 sq.in.
11.0”w.c.
14.0”w.c.
10.0”w.c.
24”
45,000
20”
36”
15”
18”
51 sq.in.
11.0”w.c.
14.0”w.c.
10.0”w.c.
30”
60,000
27”
39”
15”
18”
51 sq.in.
11.0”w.c.
14.0”w.c.
10.0”w.c.
Minimum Firebox Dimensions
Minimum
Gas Fuel Line
Manifold
Set
Input
Width
Flue
Pressure
Pressure
NOTE:
All dimensions are minimums.
NOTE:
All dimensions are minimums.
Содержание SA18SHKRN