background image

3

ODSR Series "A" Outdoor Woodburning Fireplace

20006811

NOTE: These units are intended for outdoor or indoor use in the United States and Canada using the 'SK' 

chimney system. These units may also be used outdoors or indoors in the United States and Canada using 

the 'S' chimney system with an adapter. 

Safety Information

Description

The ODSR Series "A" fireplaces are clean-faced, solid 

fuel, woodburning fireplaces. 

Precautions

Vermont Castings Group  Fireplaces and component parts 

have  been  highly  tested  and  will  operate  safely  when 

installed  in accordance  with instructions provided  in this 

manual.  Carefully  read  and  understand  all  instructions 

before

 beginning installation.

If you notice any damage to fireplace or component parts, 

immediately  report  damage  to  your  Vermont  Castings 

Group dealer.
Only use Vermont Castings Group components or the war-

ranty will be voided and a fire hazard may be created.
Vermont Castings Group warranty will be voided by and 

Vermont Castings Group disclaims any responsibility for 

the following actions:

• 

Installation of any damaged fireplace or chimney com-

ponent;

• 

Modification  of  fireplace,  chimney  assembly  or  any 

component parts thereof; (except for chase flashings 

as detailed in Vermont Castings group Chimney Top 

installation instructions).

• 

Installation other than as instructed by Vermont Cast-

ings group; or

• 

Installation  and/or  use  of  any  component  part  not 

manufactured or approved by Vermont Castings group 

in combination or assembly with a Vermont Castings 

group fireplace system, notwithstanding any indepen-

dent testing laboratory or other third party approval of 

such component parts or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in com-

pliance 

before 

installing the fireplace.

Fireplaces must be vented to the out-of-doors.

WARNINg:  To  avoid  the  risk  of  damaging  fireplace 

materials and increasing the risk of spreading a fire, 

do not use the fireplace to cook or warm food.
Do not obstruct or modify air inlets/outlets in any man-

ner. 
Do  not  install  combustible  materials  on  any  of  the 

fireplace surround.
Burn only solid wood fuel or gas logs.
Do not install a solid fuel burning insert or other prod-

ucts not specified for use with this fireplace.
These fireplaces are not approved for installation in 

mobile homes.

This fireplace is not designed to be water tight. There-

fore, when installing this unit against an exterior wall, 

the wall must be finished before setting unit in place.

Moisture Resistance

This outdoor fireplace will shed moderate amounts of wa-

ter, but is not waterproof. Water and condensing water va-

por may enter the chase under certain conditions.
The  fireplace  will  not  perform  as  an  exterior  wall.  Mois-

ture penetration must be considered for construction that 

places the fireplace in structure walls or on moisture sensi-

tive surfaces.
When installed on exterior walls: Vermont Castings Group 

recommends the fireplace chase be constructed outside 

the  structure's  weather  envelope.  Where  the  platform 

meets the wall, use a flashing detail similar to that required 

for  attached  decks.  Chase  platforms,  including  hearths 

should  slope  away  from  the  structure  at  1/4  in  per  foot. 

The fireplace can be shimmed level.
When  installed  on  surfaces  where  water  may  collect  or 

cause damage: Vermont Castings Group recommends a 

slope of 1/8 in to 1/4 in per foot towards the drain port sug-

gested. The fireplace can be shimmed level.
Hearths should slope away from the front of the fireplace 

and chase at 1/8 in to 1/4 in per foot. Metal safety strips 

must be on top of any combustible hearth materials used 

for moisture management.

Drafts

The fireplace should not be located in areas that create 

drafts (ie: frequently opened doors and central heating air 

inlets/outlets) that hamper the normal flow of air into the 

fire.

gas Logs

If you plan to install a gas log, the gas line should be installed 

before framing the fireplace. The gas line must be installed 

by a certified gas line installer.

Cleaning

There are three methods of cleaning the polished stainless 

steel of your outdoor fireplace;
1.  Warm, soapy water - to loosen any dirt film
2.  Glass cleaner with ammonia
3.  Stainless steel cleaner available at hardware stores
Regardless of which method is used, remember that any-

thing with too much abrasive may dull the finish. 

Содержание ODSR36A

Страница 1: ...urning Fireplace For Models ODSR36A ODSR42A 948 SR cover 11 18 97 20006811 1 13 Rev 15 Homeowner s Installation and Operating Manual INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future refer ence ...

Страница 2: ...ing Safety Strips Securing the Fireplace 11 Installing Outside Air Kit 12 Installing the Chimney System 12 Finishing 14 Side Wall Protection 16 Hearth Installation 16 Installing Line for Gas Logs 18 Replacement Parts 19 Accessories 20 Chimney Components 21 Warranty 23 Table of Contents ODSR36A ODSR42A Listed UL 127 ULC S610 Standard for Factory Built Fireplaces Please read this manual before insta...

Страница 3: ...stible materials on any of the fireplace surround Burn only solid wood fuel or gas logs Do not install a solid fuel burning insert or other prod ucts not specified for use with this fireplace These fireplaces are not approved for installation in mobile homes This fireplace is not designed to be water tight There fore when installing this unit against an exterior wall the wall must be finished befo...

Страница 4: ...9 mm 2256O 572 mm 2656M 667 mm 43 6M 1111 mm 14 6 372 mm 11 279 mm 8 203 mm 756O 191 mm Outside Air Gas Line Access 8 Dia 203 mm 3 6 9 1 4 m m ODSR36A Series Woodburning Fireplace Fig 1 ODSR36A specifications and framing 36 914 mm 14 6 372 mm 11 279 mm 40 1016 mm 39 6 1006 mm 5 8 16 mm 5 8 1 6 m m 4856O 1232 mm 4856O 1232 mm 1 2 13 mm 1 2 6 8 5 6 O 1 7 4 0 m m 856M 210 mm 22 559 mm 2256O 572 mm 22...

Страница 5: ... cold climate not a requirement for unit operation or exterior installation FP554 Fig 5 Fireplace and chase parts identification Termination Cap Storm Collar Pan Flashing Batt Insulation cut out around firestop Firestop Ceiling Level Draftstop Ledge Bracket Surround Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips 1 2 or 3 Outside Air Cover Plate Gas Line Access...

Страница 6: ... 9m Min NOTE If the fireplace is a freestanding unit it must be located a minimum of 10 3 m from the opening of the firebox to a combustible structure A minimum height of 6 4 1 9 m measured from the base of the firebox to the bottom of the termination cap is permitted FP1001 Fig 6 Freestanding installation ...

Страница 7: ...DSR42A Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a structural framing member The offset first elbow of any pair does not have straps IWF269 C The chimney cannot be more than 30 45 in Canada from the vertical plane in any installation D The maximum length...

Страница 8: ...1 Planning the Chimney Run Determine how the chimney will be run length of run and chimney components required to complete the job Fig 8 Never install a chimney below minimum heights In planning a chimney system it is important to know 1 The height of a chimney is measured from the hearth to the exit point on the termination 2 Achimney cannot be offset more than 30 from a vertical plane 3 A chimne...

Страница 9: ...our Vermont Castings Group dealer for assistance FP284 Fig 10 Chimney support installation FP284 MBUF 5 25 96 Chimney Support Strap SKCS8 Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible Insulate base of fireplace with a noncombustible ...

Страница 10: ... Using a plumb bob positioned directly over center point of fireplace flue collar mark the ceiling to establish the chimney center point Fig 12 Offset Installation In order to clear an obstruction it may be necessary to offset chimney from vertical This is accomplished by us ing Vermont Castings Group elbows Use the 30 Offset Elbow table on Page 5 to determine proper offset and parts required Each...

Страница 11: ...s Securing the Fireplace Slide fireplace into position Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 38 mm allowing the remainder to extend in front of firebox Overlap strips at least 1 2 13 mm to provide a positive joint Flat safety strips are packed with fireplace Fig 15 FP557 BR 11 10 97 1 FP557 Fig 15 Safety strip installation 1 2 Min Overl...

Страница 12: ... chimney pipe for ceiling thickness up to 8 203 mm When combined thickness of ceiling material ceiling joists and flooring material exceeds 8 203 mm adjustments must be made in framing to assure that minimum air spaces to chimney are maintained Proper Firestop Spacer Installation Figure 19 shows different installation procedures for both an area that is an attic and an area that is not an attic If...

Страница 13: ...f Use same procedure detailed in locating centerpoint of the flue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the type of chimney termina tion installed Refer to installation instructions provided with Vermont Castings Group chimney termination to find correct size of roof hole...

Страница 14: ...p sides must be sealed with non combustible material to prevent cold air leakage into the room Only noncombustible material may be applied to the facing of the fireplace surround Black painted area Fig 21 Finish Wall Finish the wall with material of your choice Do not install a combustible mantel shelf less than 12 305 mm from the top of the fireplace opening Do not install a mantel face plate les...

Страница 15: ...surround to bottom of screen rail Finished Wall Header Standoff Noncombustible Material Radiant Surround Face Noncombustible Facing Material Radiant Surround Face 2 x 4 Stud Finished Wall Must be sealed with Noncombustible Material FP531a Fig 22 Mantel clearances MA81 Fig 23 Combustible mantel clearances MA81 156O Ref Combustible materials are permitted within a shaded area shown in Figure 24 titl...

Страница 16: ... mm Side Wall Protection Adjacent combustible side walls that are within the mini mum dimensions shown in Figure 24 of fireplace opening must be protected with Vermont Castings Group Wall Shield Model SP40 or a specifically built wall shield described below The special wall shield design described in Figure 20 is an alternate method of adding protection to side walls and can be used in place of th...

Страница 17: ...rmine the thickness required for any new mate rial NEW K of new material per inch Thickness required X of listed thickness K of listed material per inch material Example for Common Brick T new 5 0 0 458 x 0 50 in 5 46 in new required thickness COMMON MATERIALS AND FACTORS MATERIAL K R MINIMUM THICKNESS EH2416 Common Brick 0 458 5 0 1 09 0 50 in 0 10 5 46 in MHSC R Value is for 1 2 inch Units of K ...

Страница 18: ...ace Locate appropriate gas line in the outer casing of fireplace and remove insulation from gas line tube Fig 27 From inside the fireplace locate the knockout on the fire brick be sure you are on the appropriate or gas line side of the fireplace Using a flat bladed screwdriver or small chisel and hammer carefully tap around the knockout until it loosens and falls out Install 1 2 13 mm certified ga...

Страница 19: ...225 6a Firebrick Hearth 20005621 20005421 6b Firebrick Rear 20005627 20005462 6c Firebrick Right Side 20005626 20005461 6d Firebrick Left Side 20005625 20005460 6e Firebrick Ashlip 20005619 20005418 7 Top Brick Retainers three per fireplace 3030172 3030172 8 Cable Clips four per fireplace 20006869 20006869 9 Outer Collar Assembly SK8 Chimney 3030143 3030143 10 Basket Grate 20006701 20002230 11 O S...

Страница 20: ...tributor or dealer for fin ishing Marble and Mantels available in a wide selection of styles Accessory Descritpion Model Number Glass Door Standard Bi Fold set Brushed Brass finish 36GDKBBSR ODSR36A recommended for indoor use 42GDKBBSR ODSR42A Black finish 36GDKBKSR ODSR36A recommended for indoor use 42GDKBKSR ODSR42A Polished Brass finish 36GDKDBSR ODSR36A recommended for indoor use 36GDKDBSR ODS...

Страница 21: ...op Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required for CT100 cap Chase Top Housing Low profile pyramid style chimney cap used to PLTSK8 terminate chimney through a chase Includes adapter Flashing not included Chase Top Housing Square chimney cap used to terminate chimney SLTSK8 through a chase Terra Cotta Masonry Includ...

Страница 22: ...e air to assist in cooling the chimney system Attic Insulation Shield Used to prevent insulation from coming in AIS SK contact with the chimney system 45 Chimney Elbows Provides 45 offset and return For Canadian SK845 2 installations only For use with SK8 chimney only Maximum use of 2 or 1 pair Canada Model Number Description Component Chimney Components con t ...

Страница 23: ...ponents Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local building code Building codes vary greatly throughout the country and you should determine whether your local building code contains restrictions on the use of this fireplace before you purchase it Blowers or fans which are warranted separately Heat los...

Страница 24: ...Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com ...

Отзывы: