background image

11

07/20

7101-802G

NOTE:

 Clearances may only be reduced by means 

approved by the regulatory authority having jurisdiction

NOTE:

 Hearth Rug may be used in Suggested Area

0 to 4.5 inches from bottom of unit, 

thermal protection required. R 

value of 2.9.

4.5 inches or more from bottom of 

unit, ember protection only 

required

Figure 3.17

Material
Thermal Resistance: R value

The R value is a measure of a material’s resistance to 

heat transfer.
R value is convenient when more than one material is used 

since you can add the R values together, whereas you can 

not do this for k value.
The HIGHER the R factor means less heat is being 

conducted through the non-combustible material to the 

combustible material beneath it.
The R value of a material must be equal or larger then the 

required R value to be acceptable.

Fire Risk.

•  Comply with all minimum clearances to 

combustibles as specified.

• 

Failure to comply may cause house fire.

WARNING

!

Содержание MONTPELIER II MONTP-II-BM

Страница 1: ...rty damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If heater or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING HOT SURFACES Glass and other ...

Страница 2: ...n and Installation Considerations 5 B Draft 5 C Negative Pressure 5 D Tools And Supplies Needed 6 E Inspect Appliance and Components 6 F Install Checklist 7 3 Dimensions and Clearances A Dimensions 8 B Clearances to Combustibles 10 4 Chimney Systems A Locating Your Stove Chimney 12 B Chimney Termination Requirements 13 C 2 10 3 Rule 13 D Venting Systems 14 E Inspections 14 F Chimney Height Rise an...

Страница 3: ...calculated using HHV Efficiency and the burn rates from the EPA tests using Douglas Fir dimensional lumber A peak BTU out of the appliance calculated using the maximum first hour burn rate from the High EPA Test and BTU content of seasoned cordwood 8600 times the efficiency Approved for ZC fireboxes A Insert Safety Certification C BTU Efficiency Specifications NOTE This installation must conform w...

Страница 4: ...ials Material made of or surfaced with any of the following materials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non plastered I Sleeping Room When an appliance is installed in a sleeping room an outside air kit is required and it is recommended that a smoke and or CO alarm be installed in the be...

Страница 5: ...ional codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION Asphyxiation Risk Do NOT connect this unit to a chimney flue servicing another appliance Do NOT connect to any air distribution duct or system May allow flue gases to enter the house WARNING C Negative Pressure Negativ...

Страница 6: ...w these instructions carefully during the installation to ensure maximum safety and benefit Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance...

Страница 7: ... responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Comments Further description of the issues who is responsible Installer Builder Other Trades etc and corrective action needed Comments communic...

Страница 8: ...ID 12 1 8 in 309mm 31 1 8 in 789mm 43 in 1092mm 22 in 560mm Figure 3 2 Front View with Small Surround SPVC 4331 12 1 8 in 309mm 22 in 560mm 51 in 1295mm 34 in 863mm Figure 3 5 Front View with large Surround SPVC 5134 Figure 3 3 Side View with Small Flat Surround SPVC 4331 14 in 354mm 23 3 4 in 604mm 23 1 8 in 589mm 6 1 8 in 156mm 4 in 102mm Figure 3 6 Side View with Large Surround SPVC 5134 14 in ...

Страница 9: ... 4 in 349mm 25 3 8 in 645mm Figure 3 11 Side View with Cast Surround MED CB or MED BN and Optional 15 Degree Adapter DV 6DLR E15ADSS Figure 3 10 Side View with Small or Large Surround SPVC 4331 or SPVC 5134 and Optional 15 Degree Adapter DV 6DLR E15ADSS 25 3 8 in 645mm 14 in 357mm 14 3 4 in 375mm 26 5 8 in 676mm Figure 3 13 Side View with Cast Surround MED CB or MED BN and Optional 15 Degree Adapt...

Страница 10: ... Depth Cast Surround 17 7 8 454 NOTE Clearances may only be reduced by means approved by the regulatory authority having jurisdiction NOTE If trim measurement is over 3 4 in 19mm in depth use mantle or side clearances to combustibles NOTE Minimum opening dimensions include a 1 4 inch 6mm clearance around unit B Clearances to Combustibles In Canada a full length 6 inch 152mm S635 flue liner require...

Страница 11: ... R value is a measure of a material s resistance to heat transfer R value is convenient when more than one material is used since you can add the R values together whereas you can not do this for k value The HIGHER the R factor means less heat is being conducted through the non combustible material to the combustible material beneath it The R value of a material must be equal or larger then the re...

Страница 12: ...ed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures uneven roof lines and other obstru...

Страница 13: ...or in a location of considerable air movement can cause intermittent smoke spillage from appliance Do not locate appliance near Frequently open doors Central heat outlets or returns C 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimney connector as the flue collar on the unit Changing the diameter of th...

Страница 14: ...eight may need to be increased by 2 3 per each 1000 feet above sea level It is not recommended to use offsets or elbows at altitudes above 4000 feet above sea level or when there are other factors that affect flue draft Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assi...

Страница 15: ...ifications Masonry Chimney Must Have Structural Integrity UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System Minimum 8 in 203mm Masonry Thickness in Front of Smoke Chamber Damper Plate Removed or Fastened in Open Position Seal with Non Combustible Material Minimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Follow Manufacturer...

Страница 16: ...type UL 103 HT requirements 2100 F per UL 1777 If the chimney is not listed as meeting HT requirements or if the factory built fireplace was tested prior to 1998 a full height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be securely attached to the insert flue collar and the chimney top NOTICE In Canada when using a factory built chimney i...

Страница 17: ...ance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits Inspect the existing fireplace and chimney for any damage or flaws such as burnouts metal or refectory warping Inspection to a minimum of NFPA 211 Level II is recommended All repairs must be made prior to installing an insert The fireplace must be structurally sound ...

Страница 18: ...nstalling the appliance in the outer can seal the fireplace opening and trim package with insulation to prevent air leakage into the room Option Two Installation Instructions 3 Ensure existing access hole in fireplace is sufficient to feed the 4 inch flex 4 After sliding can into fireplace feed flex into cut opening to obtain outside combustion air 5 Level outer can and install appliance NOTE Do n...

Страница 19: ...lso how to create an optional 30 elbow installation The 15 elbow may be secured directly to the flue collar Follow the pipe manufacturer s instructions for using screws or rivets for attachment Most pipe manufacturer s 6 inch 152mm diameter flue liners may be attached directly to the top of the 15 elbow 30 degree 30 Vertical Figure 5 4 5 16 Nuts Attachment Bar 5 16 Bolts Figure 5 5 D Securing Appl...

Страница 20: ...e flat surround Figure 5 7 Corner Brackets Overall Dimensions Part Number Standard Size 43 x 31 SPVC 4331 Large Size 51 x 34 SPVC 5134 Table 5 1 6 If needed push appliance back into fireplace 5 Install two steel springs on each side of the flat surround towards the bottom and the assembled trim kit Figure 5 10 4 Install two steel springs at the top on each side and between the flat surround and th...

Страница 21: ... 33 EXPVC 3349 MED CB Classic Black MED BM Majolica Brown Table 5 3 Panel Extension Assembly 1 Align holes from Surround Extension RH Side and Surround Extension Top Figure 5 14 2 Using a Phillips head screwdriver and three 3 8 x 1 2 Phillips head screws secure Surround Extension RH Side to Surround Extension Top Figure 5 14 3 Repeat steps 1 and 2 for Surround Extension LH Side Figure 5 15 Figure ...

Страница 22: ...Extension Assembly as shown in Figure 5 16 2 Using a Phillips Head screwdriver and nine 9 1 4 20 x 3 8 Phillips head screws secure Panel Extension Assembly to Cast Surround Assembly NOTE Reference Cast Surround Assembly on how to assemble cast surround set NOTE Reference Cast Surround Assembly on how to attach to the appliance Figure 5 16 Figure 5 15 DO NOT over tighten screws that attachment cast...

Страница 23: ...et UM 84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used It must be equipped with a spark arrestor cap and the outside air must be installed on the insert 5 Refer to pages 8 10 of this manual for clearance to combustibles and floor protections requi...

Страница 24: ...24 07 20 7101 802G A Service and Maintenance Log Date of Service Performed By Description of Service 7 7 Reference Materials ...

Страница 25: ...25 07 20 7101 802G Date of Service Performed By Description of Service ...

Страница 26: ...34 TRIMKIT 5134 NL 15 Degree Adapter DV 6DLR E15ADSS Additional service part numbers appear on following page 28 Cast Surround 28 2 28 1 28 3 28 4 28 5 IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a dealer or distributor Hearth and Home Technologies does not sell directly to consumers Provide model number and serial number when requesting service parts from your dealer or distrib...

Страница 27: ... x 1 Pkg of 12 27887 12 Y Nut 5 16 18 Pkg of 10 A 3483 1 10 Y Nut flange 1 4 20 Pkg of 24 226 0130 24 Y Screw FH HX 1 4 20 x 1 Pkg of 6 7000 622 6 Y Screw 10 32 x 75 HWH SF Pkg of 4 7000 618 4 Y Screw Pan Head Philips 8 32 X 3 8 Pkg of 40 225 0500 40 Y Washer SAE 3 8 3 Ea Pkg of 3 832 0990 Y Nut 2 wy Side Lock Jam 3 Pkg of 24 226 0100 24 Y Bolt Hex Washer Head Serrated Flange 1 4 20 x 3 4 Pkg of 2...

Страница 28: ...ting and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you record the following pertinent information for your heating appliance Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer Phone 1 ...