20306742
25
KHLDV Series Gas Fireplace
4. Remove safety barrier (if installed) by lifting up and out,
then remove glass frame by releasing the three latches
located at the top of the
fi
rebox. Tilt glass away from the
unit, lift glass frame up and away from the unit.
Page
45
5. Remove logs.
6. Remove hearth brick, wall brick and rear brick.
NOTE:
Remove brackets that secure wall brick.
7. Remove the access covers on the right and left side
walls of the
fi
rebox toward the front by unfastening the
screws.
NOTE: The access covers are not identical.
Figure 32
MILLIVOLT: OPTIONAL FAN/BLOWER SYSTEM
120V AC
60Hz
Factory Supplied
Not Supplied
Junction Box
Figure 31 -
Junction Box Wiring Diagram
W
A
RNING
Electrical Grounding Instructions: This appli-
ance is equipped with a three-prong (grounding)
plug for your protection against shock hazard
and should be plugged directly into a properly
grounded three prong receptacle.
W
A
RNING
Failure to replace the access cover with the one
provided with the blower kit, and then running
the blower, will cause excessive temperatures
and could cause a fi re, property damage and/or
loss of life.
Figure 32 -
Blower Access Covers
FP2136
8. Two screws are already mounted to each cover which
would be utilized to mount the blower to the cover.
Unfasten the two screws and mount the blower bracket
assemblies.
Figure 33
9. Consult blower wiring diagram and start the assembly.
Figures 31 & 34.
It is helpful to wire the right blower,
the speed control, the fan limit switch, and the power
cord
fi
rst. Then plug in the power cord to the junction
box and secure the right cover plate/blower assembly
to the side of the
fi
rebox.
10. Assemble the wire clips provided with the blower kit to
the right and left sides of the
fi
replace through existing
holes on right and left.
11. Run the wire harness down the right and snap wires
into the clips assembled in #10. Run the two wires
along the glass track, on the
fl
oor of the unit, in front
of the
fi
rebox
12. Snap the fan limit switch behind the clip already assem-
bled to the side of the
fi
rebox on the front right hand
side.
Figure 35
13. Secure the left access plate/blower assembly to the
left side of the
fi
rebox. Run the two wires mentioned
earlier up the left
fi
rebox wall and snap wires into clip
assembled in #10 on the outer shell wall. Make the
connection to the left blower. Replace the refractory
and hearth refractory (pull away from burner toward
the front).
Figure 33 -
Attach Blowers to Brackets
FP2233