12
Encore
®
FlexBurn
®
2040 Non-Catalytic / Catalytic Wood Burning Stove
30005295
(A) 19"
(B) 20"
(C) 18
1
⁄
2
"
(D) 5"
(E) 7"
(F) 12"
(483 mm)
(508 mm)
(470 mm)
(127 mm)
(178 mm)
(305 mm)
(G) 19"
(H) 10"
(I) 18
1
⁄
2
"
(J) 6"
(K) 6"
(L) 12"
(483 mm)
(254 mm)
(470
mm)
(152 mm)
(152 mm)
(305 mm)
(M) 22"
(N) 12"
(P) 11”
(Q) 12"
(559 mm)
(305 mm)
n/a
(279 mm)
(305 mm)
n/a
(G) 18"
(H) 7"
(I) 12"
(J) 4"
(K) 5"
(L) 5"
(457 mm)
(178 mm)
(305 mm)
(102 mm)
(127 mm)
(127 mm)
Stove Clearance
Unprotected Surfaces
Protected Surfaces
Clearance Chart
For use with either 6” or 8” flue collar/chimney connection
Stove Installed
Stove
Stove Installed
Stove
Parallel to Wall
in Corner
Parallel to Wall
in Corner
1
Side
To Rear
Corners
Side
To Rear
Corners
Shroud
Shroud
Top Exit, 8” single
wall connector without
shields, vertical flue col-
lar heat shield installed
Top Exit,
single-wall
chimney connector heat
shield
2
, vertical flue col-
lar h.s. installed
Rear Exit
No flue collar heat
shield
Top Exit,
double-wall
chimney connector
3
,
vertical flue collar heat
shield installed
Clearance to Combustible in Front of Stove
All Installations (S) 48" (1219 mm)
The provided rear shroud must be used in all installations. The flue collar heat shield must be used in all vertical
installations.
1. A ceiling heat shield 24" (610 mm) in diameter and suspended 1" (25 mm) from the ceiling must surround the
pipe in installations where chimney penetrates the ceiling.
2. The connector pipe heat shield must extend 36" (914 mm) above flue collar.
3. Using listed double wall oval to round adapter when installing optional 8" oval flue collar.
Top Exit
, single wall
6" connector without
shields, vertical flue col-
lar heat shield installed
(A) 19"
(B) 15"
(C) 18
1
⁄
2
"
(D) 5"
(E) 7"
(F) 12"
(483 mm)
(381 mm)
(470 mm)
(127 mm)
(178 mm)
(305 mm)
6" Chimney Connector ONLY