26D3310
7
SPECIFICATIONS
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has three (3) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
HI/LOW
- Variable position corresponding to desired fl ame height.
Hi/Lo valve control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
PILOT
- Valve position to light/maintain a standing pilot.
ON
- Valve position to turn ON.
HI/LOW
- Variable position corresponding to desired fl ame height back to pilot.
Milli-Volt and T-Stat control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI
- Variable position to control fl ame height (heat output). Both front and rear burners are in operation
to provide realistic glow and yellow fl ame.
PILOT
The gas log heater is fi tted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The milli-volt gas log pilot is fi tted with a milli-volt generator to provide power for remote activation.
Содержание DFS3224A
Страница 38: ...38 26D3310 NOTES...
Страница 39: ...26D3310 39 NOTES...