24
26D3310
In normal operation at full rate after 15 minutes, the following fl ame appearances should be observed:
Figure 29 - Correct Appearance of Rear Flames
The left and right rear fl ames should be yellow and extend 1"-2" above the log top surfaces. The yellow fl ames should
not
contact the logs. There should be glowing embers on the front surface of middle log.
Note: The fl ames and embers
will be an opaque orange color during the burn off time.
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner fl ame patterns.
Do not allow fans to blow directly into the fi replace. Do
not place a blower inside the burn area of the fi rebox. Ceiling fans may create drafts that alter fl ame patterns. Sooting
and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils,
fi lms or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are
burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation.
This is
a normal and temporary occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum
ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will
be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe
sooting outside the fi replace.
CHECKING THE BURNER FLAME
Glowing Embers