- 6 -
INSTALLATION OF LOGS
1.
Turn off power to the unit.
2.
Remove front glass (See "Glass Removal" section).
3.
Remove logs from packaging.
4.
The ember bed is shipped in place. No adjustment is
necessary.
5.
Install rear left log (A15). Use notches to have a proper
location.
6.
Install rear right log (A16). Use notches to have a
proper location.
7.
Install front left log (A13). Use notches to have a
proper location.
8.
Install front right log (A14). Use notches to have a
proper location.
Fig. 6
CABINET INSTALLATIONS
Cabinets are available from your dealer which allow for
fast, convenient installation of your fireplace against exist-
ing walls.
Electrical outlet wiring must comply with
local building codes and other applicable
regulations to reduce the risk of fire,
electrical shock and injury to persons.
ELECTRICAL CONNECTION
A 15 AMP, 240 Volt, 50 Hz circuit with a properly grounded
outlet is required. Preferably, the fireplace will be on a
dedicated circuit as other appliances on the same circuit
may cause the circuit breaker to trip or the fuse to blow
when the heater is in operation. The unit comes standard
with a 7 ft. (2134 mm) long three wire cord, exiting the right
side of the fireplace. Plan the installation to avoid the use
of an extension cord. If an extension cord must be used,
it must be a minimum 16AWG, three wire with grounding
type plug and connector and rated not less than 2500
Watts.
A new electrical outlet can be installed inside the frame
construciton, if permitted by local codes.
Do not use this fireplace if any part of it has
been under water. Immediately call a
qualified service technician to inspect the
fireplace and replace any part of the
electrical system which has been under
water.
Hard (Direct) Wire Connection
If desired, a qualified electrician may remove the cord
conection and wire this unit directly to the household
wiring.
Any electrical re-wiring of this appliance
must be done by a qualified electrician.
WARNING: Safe use plug must be
accessible after installation.
WARNING: This appliance is fitted with a
non-rewireable plug. If it’s necessary to
change the fuse in a plug. The fuse cover
must be refitted. If the fuse cover is lost or
damaged, the plug must not be used until it
is replaced. It is important that the colour of
the replacement fuse cover corresponds
with the colour markings on the base of the
plug. An ASTA approved BS1362 fuse rated
at 13A should be used.