background image

7

10005898

Vermont Castings, Majestic Products, DEF33/36, DEFD33/ 36

Installation of DEF33 Logs

Refer to Figure 4.

1. Turn off power to the unit.

2. Remove front glass (See "Glass Removal" section),

or open front doors.

3. Remove logs from packaging.

4. The ember lava rock is shipped in place; no

adjustment is necessary.

5. Fit the log right (A37) onto plate log support. Ensure

the bottom holes of the log are located on the two
pins of the support.

6. Fit the log left (A38) onto plate log support. Ensure

the bottom holes of the log are located on the two
pins of the support.

7. Place the log center (A39) on ember lava rock. Use

the notches under the log center to properly locate
the log. The top of this log sets on the log right.

8. Place the log left top (A40) in position by resting

the hole under the center of this log over the knob
on the log left, and the front of log sets on the log
center and against the back wall of plate log
support.

1005694

Fig. 4   DEF33/DEFD33 Logset

Installation of DEF36 Logs

(B116)

(B115)

(B119)

(B118)

MVC_002F

Fig. 5   DEF36/DEFD36 Logset

Refer to Figure 5.

1. Turn off power to the unit.

2. Remove front glass (See "Glass Removal" section),

or open front doors.

3. Remove logs from packaging.

4. The ember lava rock is shipped in place; no

adjustment is necessary.

5. Place the center log (B117) on the ember lava rock.

Use the notches under the log center to have a
proper location.

6. Place the right log (B115) onto the plate log support.

Ensure the bottom of the log sets against the side
wall of plate log support, and the top of the log sets
on the log center.

7. Place the left log (B116) onto the plate log support.

Ensure the side of the log sets against the  side wall
of plate log support and the back of the log sets
against the tinted light screen.

8. Place the crossover left log (B119) in position by

resting the top of the log on the log left. The other
end of the log sets against the back wall of the plate
log support.

9. Place the crossover right log (B118) in position by

resting the top of the log on the log right. The other
end of the log sets against the back wall of the plate
log support.

A40

A39

A37

A38

(B117)

Содержание DEF33

Страница 1: ...NFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qualifie...

Страница 2: ...abinet Installations 3 Fireplace Dimensions 4 Electrical Specifications 4 Mantels 5 Framing and Finishing 6 Electrical Connection 6 Hard Direct Wire Connection 6 Installation of DEF33 Logs 7 Installat...

Страница 3: ...ireplace again 7 Do not use outdoors 8 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate this appliance where it may fall into a bathtub or other...

Страница 4: ...28 7 8 733mm 341 4 870mm C 31 787mm 33 838mm D 16 3 8 416mm 21 533mm E 6 27 64 163mm 6 27 64 163mm F 4 102mm 5 3 8 137mm G 11 1 2 292mm 14 356mm H 221 16 560mm 221 8 562mm I 3 76mm 33 4 95mm Framing...

Страница 5: ...the mantel such paint or lacquer must be heat resistant to prevent discoloration J F G H I Mantel Leg Black Surround Face CFM164a O N M L K Side of Combustion Chamber CFM170 Fig 2b Combustible mantel...

Страница 6: ...lified electrician may remove the cord connection and wire this unit directly to the household wiring See page 15 Any electrical rewiring of this appliance must be done by a qualified electrician This...

Страница 7: ...ogset Installation of DEF36 Logs B116 B115 B119 B118 MVC_002F Fig 5 DEF36 DEFD36 Logset Refer to Figure 5 1 Turn off power to the unit 2 Remove front glass See Glass Removal section or open front door...

Страница 8: ...or open glass doors 4 Remove the four 4 screws securing the ember bed in position Two screws 2 are located on either side of the ember bed near the front 5 Examine the bulbs to determine which bulbs...

Страница 9: ...ation 1 Motor Variable Speed 12VDC 2 Switch ON OFF 3 Thermostat 4 Fan Heater 5 Light Socket with Wiring Assem 6 Light Bulb 60W 7 Breaker Circuit Manual Reset 8 Power cord 16 3 HPN with Terminal 9 Bush...

Страница 10: ...eramic refractory installation Electrical Wiring Diagram without Integral Remote Control Wiring Color Code WH White BL Black RE Red Component Identification 1 Motor Variable Speed 12VDC 2 Switch ON OF...

Страница 11: ...ils sur le service Voir les instructions d installation pour heater least 3 feet 0 9m from the front of the cords draping and other furnishings at WARNING Risk of fire keep electrical Servicing WARNIN...

Страница 12: ...scontinue colors and products at any time without notice DEF33 36 DEFD33 36 Electric Fireplace 15 19 26 12 11 13 17 14 15 305mm 12 305mm 12 216mm 8 1 2 DIST 216mm 8 1 2 DISTANCE BETWEEN ANCE BETWEEN T...

Страница 13: ...ometer 10001639 10001639 10001639 10001639 9 Screen Tinted Plastic Not shown 10005518 10005518 10005954 10005954 10 Flame Generator Assembly 10003350 10003350 10003350 10003350 11 Glass with Gasket 4W...

Страница 14: ...Remove the deflector cabinet top from the top radiant face Save the screws and deflector cabinet top to reinstall into the top Radiant panel 3 Open the access Radiant face door then remove the bottom...

Страница 15: ...knife as this may expose bare conductor The hot wire is connected to the circuit breaker The neutral wire is connected to the rocker switch and the green ground wire is attached to a ground stud on th...

Страница 16: ...estic Products aux pr sentes nomm e la Soci t garantit votre nouveau foyer lectrique Vermont Castings Majestic Products contre tous d fauts de fabrication et de mati res premi res pour une p riode d u...

Отзывы: