background image

15

10005898

Vermont Castings, Majestic Products, DEF33/36, DEFD33/ 36

Direct (Hard) Wiring

Electric Fireplace Models

DEF33/ DEF36/ DEF36S2

WARNING:This procedure must be conducted by a
qualified electrician, in accordance with National and
local codes. In the U.S.A., the installation must
conform to the National Electrical Code, ANSI/NFPA
No. 70. In Canada, the installation must conform to the
current CSA C22.1 Canadian Electrical Code.

WARNING: Make sure the power to the unit is off, and
the power cord is unplugged from the wall outlet before
proceeding with this conversion. Failure to do so may
result in property damage, personal injury or loss of life.

This instruction is intended as a guide for replacing the
power cord supplied with Models HEF33/DEF33/
DEF36/DEF36S2 electric fireplace with direct (hard)
wiring.

NOTE: When direct wiring this appliance, it must be
connected to a 15 Amp dedicated circuit breaker or
fuse in the electrical panel of the dwelling. The cable
between the circuit/fuse panel and the fireplace must
meet all local and national codes, and in no case shall
the wires be less than 14 gauge.

1. Make sure the power to the unit has been turned

off, the power cord is unplugged from the wall outlet
and the unit has cooled down if it has been
operating.

2. Lower the bottom louvre panel to expose the

control panel.

3. Using a phillips screwdriver, remove the two screws

on the side tabs of the control panel that secure the
panel to the cabinet.

4. Grasp the tabs on the control panel and gently lean

the top of the panel towards you while lifting it up
until the locking tabs on the bottom of the control
panel are disengaged from the bottom of the unit.
Lay the control panel face down on top of the louvre
panel. Do not force the panel, as this may result in
wires being disconnected from their controls.

5. Locate where the power cord enters the control

compartment on the right hand side of the unit.
Using wire cutters, cut the power cord within three
inches (75 mm) of the point where it exits the
cabinet.

6. Carefully separate the three wires of the power cord

into separate wires by gently pulling them apart.
DO NOT use a knife, as this may expose bare
conductor. The hot wire is connected to the circuit
breaker. The neutral wire is connected to the rocker
switch and the green ground wire is attached to a
ground stud on the rear panel of the control
compartment.

7. Using wire strippers, strip approximately 

5

/

8

"

(15 mm) from the ends of the hot and neutral wires.

8. Using a wrench, remove the #10-24 hex nut from

the ground stud where the green wire from the
power cord is attached. Remove and discard the
green wire. Reinstall the nut but do not tighten yet.

9. Standing on the right side of the unit, locate the

power cord where it exits the cabinet. Using pliers,
gently cut and remove the power cord. Dispose of
the power cord.

10. Using a slotted screwdriver, remove the 

7

/

8

"

(22 mm) diameter knockout from the right hand side
of the cabinet below where the strain relief was
located.

11. Route the electrical cable from the breaker/ fuse

panel through the 

7

/

8

" (22 mm) diameter hole and

secure to the cabinet using an approved clamp.
The power wires should extend approximately
6" (152 mm) into the control compartment.

WARNING: Make sure the power to the power cable
has been turned off at the breaker/ fuse panel of the
residence before proceeding.

12. Connect the ground wire form the power cable by

wrapping it around the ground stud of the unit and
securing it using the #10-24 nut.

13. Using a wire nut, connect the hot lead (black), of

the power cable to the power cord wire leading to
the circuit breaker on the control panel. Similarly,
connect the neutral wire (white), of the power cable
to the power cord wire leading to the rocker switch,
using a wire nut. It is recommended that the wire
nuts be taped to the wires, using electrical tape, as
an extra safety measure.

14. Visually check that none of the wires in the control

compartment have been dislodged from the
controls. If they have, use the wiring diagram on
the unit or in the instruction manual to replace
them in their proper location.

15. Reinstall the control panel and secure it using the

screws removed in step 3. Make sure that wires do
not become pinched when replacing the panel.

16. Make sure that the rocker switch on the control

panel is in the off position. Turn the power to the
unit on at the breaker/ fuse panel. Place the unit into
operation and check to make sure that all of the
systems are working properly.

Содержание DEF33

Страница 1: ...NFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qualifie...

Страница 2: ...abinet Installations 3 Fireplace Dimensions 4 Electrical Specifications 4 Mantels 5 Framing and Finishing 6 Electrical Connection 6 Hard Direct Wire Connection 6 Installation of DEF33 Logs 7 Installat...

Страница 3: ...ireplace again 7 Do not use outdoors 8 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate this appliance where it may fall into a bathtub or other...

Страница 4: ...28 7 8 733mm 341 4 870mm C 31 787mm 33 838mm D 16 3 8 416mm 21 533mm E 6 27 64 163mm 6 27 64 163mm F 4 102mm 5 3 8 137mm G 11 1 2 292mm 14 356mm H 221 16 560mm 221 8 562mm I 3 76mm 33 4 95mm Framing...

Страница 5: ...the mantel such paint or lacquer must be heat resistant to prevent discoloration J F G H I Mantel Leg Black Surround Face CFM164a O N M L K Side of Combustion Chamber CFM170 Fig 2b Combustible mantel...

Страница 6: ...lified electrician may remove the cord connection and wire this unit directly to the household wiring See page 15 Any electrical rewiring of this appliance must be done by a qualified electrician This...

Страница 7: ...ogset Installation of DEF36 Logs B116 B115 B119 B118 MVC_002F Fig 5 DEF36 DEFD36 Logset Refer to Figure 5 1 Turn off power to the unit 2 Remove front glass See Glass Removal section or open front door...

Страница 8: ...or open glass doors 4 Remove the four 4 screws securing the ember bed in position Two screws 2 are located on either side of the ember bed near the front 5 Examine the bulbs to determine which bulbs...

Страница 9: ...ation 1 Motor Variable Speed 12VDC 2 Switch ON OFF 3 Thermostat 4 Fan Heater 5 Light Socket with Wiring Assem 6 Light Bulb 60W 7 Breaker Circuit Manual Reset 8 Power cord 16 3 HPN with Terminal 9 Bush...

Страница 10: ...eramic refractory installation Electrical Wiring Diagram without Integral Remote Control Wiring Color Code WH White BL Black RE Red Component Identification 1 Motor Variable Speed 12VDC 2 Switch ON OF...

Страница 11: ...ils sur le service Voir les instructions d installation pour heater least 3 feet 0 9m from the front of the cords draping and other furnishings at WARNING Risk of fire keep electrical Servicing WARNIN...

Страница 12: ...scontinue colors and products at any time without notice DEF33 36 DEFD33 36 Electric Fireplace 15 19 26 12 11 13 17 14 15 305mm 12 305mm 12 216mm 8 1 2 DIST 216mm 8 1 2 DISTANCE BETWEEN ANCE BETWEEN T...

Страница 13: ...ometer 10001639 10001639 10001639 10001639 9 Screen Tinted Plastic Not shown 10005518 10005518 10005954 10005954 10 Flame Generator Assembly 10003350 10003350 10003350 10003350 11 Glass with Gasket 4W...

Страница 14: ...Remove the deflector cabinet top from the top radiant face Save the screws and deflector cabinet top to reinstall into the top Radiant panel 3 Open the access Radiant face door then remove the bottom...

Страница 15: ...knife as this may expose bare conductor The hot wire is connected to the circuit breaker The neutral wire is connected to the rocker switch and the green ground wire is attached to a ground stud on th...

Страница 16: ...estic Products aux pr sentes nomm e la Soci t garantit votre nouveau foyer lectrique Vermont Castings Majestic Products contre tous d fauts de fabrication et de mati res premi res pour une p riode d u...