background image

13

10005898

Vermont Castings, Majestic Products, DEF33/36, DEFD33/ 36

DEF33/36; DEFD33/36 Electric

 

Fireplace

 

(continued)

Description

DEF33

DEFD33

DEF36

DEFD36

1.

Log Set Complete

10005694

10005694

10006091

10006091

1a.

Log

10005690 (A37)

10005690 (A37) 10006086 (B115) 10006086 (B115)

1b.

Log

10005691 (A38)

10005691 (A38) 10006087 (B116) 10006087 (B116)

1c.

Log

10005692 (A39)

10005692 (A39) 10006088 (B117) 10006088 (B117)

1d.

Log

10005693 (A40)

10005693 (A40) 10006089 (B118) 10006089 (B118)

1e.

Log

10006090 (B119) 10006090 (B119)

2.

Fan/ Heater

10004198

10004198

10004198

10004198

3.

Motor 12VDCFlame Generator

10001978

10001978

10001978

10001978

4.

ON/ OFF Switch (Illuminated)

10001393

10001393

10001393

10001393

5.

Thermostat - Heater Control

10004199

10004199

10004199

10004199

6.

Potentiometer – Flame Speed Control

10001168

10001168

10001168

10001168

7.

Circuit Board – Flame Speed Control

10001589

10001589

10001589

10001589

8.

Knob – Flame Speed,
     Heater Controls & Potentiometer

10001639

10001639

10001639

10001639

9.

Screen, Tinted Plastic (Not shown)

10005518

10005518

10005954

10005954

10.

Flame Generator Assembly

10003350

10003350

10003350

10003350

11.

Glass with Gasket 4W-25

10005529

10005937

12.

Gasket Glass

10001882

10001882

13.

Frame Window

10003432

10003352

14.

Panel Radiant Assembly Top

10004391

10004391

10004484

10004484

15.

Panel Access Radiant Assembly

10005515

10005515

10005934

10005934

16.

Plate Support Log Set Assembly

10005695

10005695

10005956

10005956

17.

Trim-Frame Window (PB)
     (with 2 Magnets)

55005

57480

18.

Facia Control System

10005683

10005510

10005929

10005931

19.

Breaker Circuit Manual Reset

10003093

10003093

10003093

10003093

20.

Card Power 16/3 HPN with Terminals

10003095

10003095

10003095

10003095

21.

Socket Light Bulb Lower Assembly

10003127

10003127

10003127

10003127

22.

Ember Lava Rock

10005570

10005570

10005955

10005955

23.

Door with Glass Right Assembly

10005679

10005952

24.

Door with Glass Left Assembly

10005680

10005953

25.

Transmitter

10005140

10005140

26.

Receiver

10005141

10005141

27.

CFM-Majestic Wire Req’d. (not shown)

10005662

10005569

10005935

10005936

Содержание DEF33

Страница 1: ...NFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qualifie...

Страница 2: ...abinet Installations 3 Fireplace Dimensions 4 Electrical Specifications 4 Mantels 5 Framing and Finishing 6 Electrical Connection 6 Hard Direct Wire Connection 6 Installation of DEF33 Logs 7 Installat...

Страница 3: ...ireplace again 7 Do not use outdoors 8 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate this appliance where it may fall into a bathtub or other...

Страница 4: ...28 7 8 733mm 341 4 870mm C 31 787mm 33 838mm D 16 3 8 416mm 21 533mm E 6 27 64 163mm 6 27 64 163mm F 4 102mm 5 3 8 137mm G 11 1 2 292mm 14 356mm H 221 16 560mm 221 8 562mm I 3 76mm 33 4 95mm Framing...

Страница 5: ...the mantel such paint or lacquer must be heat resistant to prevent discoloration J F G H I Mantel Leg Black Surround Face CFM164a O N M L K Side of Combustion Chamber CFM170 Fig 2b Combustible mantel...

Страница 6: ...lified electrician may remove the cord connection and wire this unit directly to the household wiring See page 15 Any electrical rewiring of this appliance must be done by a qualified electrician This...

Страница 7: ...ogset Installation of DEF36 Logs B116 B115 B119 B118 MVC_002F Fig 5 DEF36 DEFD36 Logset Refer to Figure 5 1 Turn off power to the unit 2 Remove front glass See Glass Removal section or open front door...

Страница 8: ...or open glass doors 4 Remove the four 4 screws securing the ember bed in position Two screws 2 are located on either side of the ember bed near the front 5 Examine the bulbs to determine which bulbs...

Страница 9: ...ation 1 Motor Variable Speed 12VDC 2 Switch ON OFF 3 Thermostat 4 Fan Heater 5 Light Socket with Wiring Assem 6 Light Bulb 60W 7 Breaker Circuit Manual Reset 8 Power cord 16 3 HPN with Terminal 9 Bush...

Страница 10: ...eramic refractory installation Electrical Wiring Diagram without Integral Remote Control Wiring Color Code WH White BL Black RE Red Component Identification 1 Motor Variable Speed 12VDC 2 Switch ON OF...

Страница 11: ...ils sur le service Voir les instructions d installation pour heater least 3 feet 0 9m from the front of the cords draping and other furnishings at WARNING Risk of fire keep electrical Servicing WARNIN...

Страница 12: ...scontinue colors and products at any time without notice DEF33 36 DEFD33 36 Electric Fireplace 15 19 26 12 11 13 17 14 15 305mm 12 305mm 12 216mm 8 1 2 DIST 216mm 8 1 2 DISTANCE BETWEEN ANCE BETWEEN T...

Страница 13: ...ometer 10001639 10001639 10001639 10001639 9 Screen Tinted Plastic Not shown 10005518 10005518 10005954 10005954 10 Flame Generator Assembly 10003350 10003350 10003350 10003350 11 Glass with Gasket 4W...

Страница 14: ...Remove the deflector cabinet top from the top radiant face Save the screws and deflector cabinet top to reinstall into the top Radiant panel 3 Open the access Radiant face door then remove the bottom...

Страница 15: ...knife as this may expose bare conductor The hot wire is connected to the circuit breaker The neutral wire is connected to the rocker switch and the green ground wire is attached to a ground stud on th...

Страница 16: ...estic Products aux pr sentes nomm e la Soci t garantit votre nouveau foyer lectrique Vermont Castings Majestic Products contre tous d fauts de fabrication et de mati res premi res pour une p riode d u...