background image

Vermont Castings  •  Dauntless FlexBurn Installation Manual_R8  •  2020 - ___ •  11/21

19

3-90-586000i

Figure 5.4

 - Assemble the fall away door handle.

Storing the Handle

Use the removable handle to open or close the doors. After 

using it, remove the handle so it will not get hot. Store the 

handle in the handle holder installed behind the left front 

leg, Figure 5.5.

Figure 5.5

 - Handle holder and heat shield positions.

Handle

Handle Holder

C. Smoke and CO Detectors & Safety Tips

Smoke and CO Detectors

The  use  of  smoke  and  carbon  monoxide  (CO)  detectors 

throughout the home is strongly advised, even if not 

required by building codes or insurance regulations. 

It  is  a  good  idea  to  install  a  smoke  detector  in  the  living 

areas  and  each  bedroom.  Follow  the  smoke/CO  detector 

manufactures placement and installation instructions and 

maintain regularly.

You  may  not,  however,  wish  to  install  a  detector  in  the 

immediate vicinity of the stove. Depending on the sensitivity 

of the unit, the alarm can be set off while you are tending 

the fire or emptying the ashes. If you install a detector in the 

same room, locate it as far away from the stove as possible.

Safety Tips

Conveniently locate a “Class A” fire extinguisher to contend 

with  small  fires.  Be  sure  the  fire  extinguisher  works  and 

is clearly visible. All occupants of the house should know 

where it is, and how it operates. Have heavy stove gloves 

available near the stove. Have special safety accessories 

(e.g., Child Guard Screen) available for use if small children 

will be in the home.

Fire Risk

•  Do not leave the fire unattended when the 

door is unlatched.

•  Unstable firewood could fall out of the firebox 

creating a fire hazard to your home.

WARNING

!

In the event of a stove pipe or chimney fire….
•  Evacuate the house immediately
•  Notify the fire department
•  If the fire isn’t too threatening, closing down the stove 

tight, (damper, primary air, all doors) will help to smother 

the fire.

•  Inspect  your  stove,  vent  pipe  and  chimney  for  any 

damage  caused  by  the  fire  and  correct  any  damage 

before using your stove again.

D. Reverse the Flue Collar 

(If necessary)

Tools Required:

 Phillips head screwdriver.

The flue collar is reversible for either a top or rear venting 

installation. The appliance is shipped with the flue collar in 

the top vent position. 

Converting Collar For Rear Vent Installation

1.  Remove (10) #8 Tek screws from the heat shield cover and 

heat shield. Remove heat shield and cover, Figure 5.6.

2.  Remove (2) 1/4-20 pan head screws from the flue collar. 

Remove flue collar, Figure 5.6.

3.  Turn flue collar to horizontal position. Inspect rope gasket 

located on the rear cast housing to ensure a leak free seal. 

Re-install flue collar, heat shield and heat shield cover, 

Figure 5.7.

Note:

 There is a knockout on the rear air jacket that will need to 

be removed prior to installing the flue collar for it to fit properly 

to the unit, Figure 5.11. 

Figure 5.6

Flue Collar

Top Heat Shield Cover

Heat Shield

Содержание Dauntless FlexBurn

Страница 1: ...the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combu...

Страница 2: ...ations 3 E Non Combustible Materials 4 F Combustible Materials 4 G California 4 2 Getting Started A Design and Installation Considerations 5 B Fire Safety 5 C Negative Pressure 5 D Tools And Supplies...

Страница 3: ...6 Inch 152 mm Firebox Size 1 8 cu ft Outside Air Size 3 Inch Recommended Length 16 Inch Max Wood Length 18 Inch Fuel Orientation East West Fuel Seasoned Cordwood 20 moisture or less Weighted average...

Страница 4: ...r surfaced with any of the following materials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non pla...

Страница 5: ...hould be given serious consideration 1 Install at least one smoke detector on each floor of your home to ensure your safety They should be located away from the heating appliance and close to the slee...

Страница 6: ...duct work and air handler joints and seams taped or sealed Basement installations should be avoided Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwd...

Страница 7: ...e with proper clearance Chimney meets recommended height requirements Minimum 16 Feet Roof flashing installed and sealed Terminations installed and sealed Clearances Combustible materials not installe...

Страница 8: ...lass surface Door opening width 24 5 8 625 mm 17 1 2 445 mm 16 3 8 416 mm 18 7 16 479 mm 23 1 16 586 mm 25 3 4 654 mm 25 5 8 651 mm 25 3 4 654 mm 13 3 8 340 mm 27 686 mm 22 5 8 575 mm Figure 3 2 Side...

Страница 9: ...ingle wall pipe 1 6 0 0 m m 8 1 0 m m 9 3 1 m m 1 4 6 7 m m 4 5 7 m m f r o n t d o o r o p e n i n g CANADA Figure 3 7 457MM FRONT DOOR OPENING 203MM 1114mm minimum 1254mm minimum 203MM Must extend 5...

Страница 10: ...Pipe 10 26 1 2 14 For Factory Alcove 6 diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A Chimney or Masonry chimney Maximum depth Alcove shall be no m...

Страница 11: ...20 Figure 3 13 Disclaimers Extended floor protection may be required for shallow installs follow floor protection requirements Full insertion installation may not allow use of the top load door depen...

Страница 12: ...chimney should Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the r...

Страница 13: ...g the diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when there are other facto...

Страница 14: ...d in these installations but manufacturers are no longer permitted to specify these on EPA Certified models The chimney system should be carefully reviewed and draft tested if possible prior to instal...

Страница 15: ...ys Chimney The chimney can be new or existing masonry or prefabricated and must meet the following minimum requirements specified in Section 4B C Chimney Systems Prefabricated Metal Chimney Must be mi...

Страница 16: ...lumber to fit into wall opening Inside opening of frame should be no less than 14 x 14 356 mm x 356 mm Figure 4 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wal...

Страница 17: ...e 6 152mm UL103 HT WARNING WARNING Asphyxiation Risk DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM May allow flue ga...

Страница 18: ...ll the Bottom Heat Shield NOTE TheBottomHeatShieldisrequiredinmostinstallations Refer to Floor Protection in the Dimensions and Clearances Section of this manual for further details 1 Align the bottom...

Страница 19: ...heavy stove gloves available near the stove Have special safety accessories e g Child Guard Screen available for use if small children will be in the home Fire Risk Do not leave the fire unattended wh...

Страница 20: ...e wall or flooring in your home 1 Remove all materials from packing box 2 Using a 2 Phillips screw driver attach the flex adapter to the appliance using 4 screws Figure 5 8 5 9 3 Floor Rear Installati...

Страница 21: ...rk Metalbestos DS or Security DL double wall connector or any listed double wall connector pipe 5 In Canada this appliance must be connected to a 6 152 mm factory built chimney conforming to CAN ULC 6...

Страница 22: ...mportant operating and maintenance instructions included Leave this manual with party responsible for use and operation Read understand and followtheseinstructions for safe installation and operation...

Отзывы: