F. Chimney Termination Requirements

Follow manufacturer’s instructions for clearance, securing 

flashing and terminating the chimney, Figures 3.15 & 3.16.
•  Must have an approved and Listed cap

•  Must not be located where it will become plugged by 

snow or other material

•  Must  terminate  at  least  3  feet  (91  cm)  above  the  roof 

and

 at least 2 feet (61 cm) above any portion of the roof 

within 10 feet (305 cm).

•  Must be located away from trees or other structures

NOTICE:

•  Chimney performance may vary.

•  Trees,  buildings,  roof  lines  and  wind  conditions  affect 

performance.

•  Chimney  height  may  need  adjustment  if  smoking  or 

overdraft occurs.

E. Locating Your Appliance & Chimney

Location  of  the  appliance  and  chimney  will  affect 

performance. As shown in Figure 3.14 the chimney should:

•  Install through the warm space enclosed by the building 

envelope. This helps to produce more draft, especially 

during lighting and die down of the fire.

•  Penetrate the highest part of the roof. This minimizes the 

affects of wind turbulence and down drafts.

NOTICE: 

Locating  the  appliance  in  a  basement  or  in  a 

location of considerable air movement can cause intermittent 

smoke spillage from appliance. Do not locate appliance near

•  Frequently open doors
•  Central heat outlets or returns

•  Consider  the  appliance  location  in  order  to  avoid  floor 

and ceiling attic joists and rafters.

• 

Locate  termination  cap  away  from  trees,  adjacent 

structures, uneven roof lines and other obstructions.

Your local dealer is the expert in your geographic area and 

can usually make suggestions or discover solutions that will 

easily correct your flue problem.

Figure 3.14

Recommended 

Location

Marginal

Location

Location

Not

Recommended

 

Recommended

Location

 

Location NOT 

Recommended

Multi-level Roofs

Windward

Leeward

Outside Air Termination Cap

Содержание Dauntless FlexBurn

Страница 1: ...the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combu...

Страница 2: ...ations 3 E Non Combustible Materials 4 F Combustible Materials 4 G California 4 2 Getting Started A Design and Installation Considerations 5 B Fire Safety 5 C Negative Pressure 5 D Tools And Supplies...

Страница 3: ...6 Inch 152 mm Firebox Size 1 8 cu ft Outside Air Size 3 Inch Recommended Length 16 Inch Max Wood Length 18 Inch Fuel Orientation East West Fuel Seasoned Cordwood 20 moisture or less Weighted average...

Страница 4: ...r surfaced with any of the following materials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non pla...

Страница 5: ...hould be given serious consideration 1 Install at least one smoke detector on each floor of your home to ensure your safety They should be located away from the heating appliance and close to the slee...

Страница 6: ...duct work and air handler joints and seams taped or sealed Basement installations should be avoided Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwd...

Страница 7: ...e with proper clearance Chimney meets recommended height requirements Minimum 16 Feet Roof flashing installed and sealed Terminations installed and sealed Clearances Combustible materials not installe...

Страница 8: ...lass surface Door opening width 24 5 8 625 mm 17 1 2 445 mm 16 3 8 416 mm 18 7 16 479 mm 23 1 16 586 mm 25 3 4 654 mm 25 5 8 651 mm 25 3 4 654 mm 13 3 8 340 mm 27 686 mm 22 5 8 575 mm Figure 3 2 Side...

Страница 9: ...ingle wall pipe 1 6 0 0 m m 8 1 0 m m 9 3 1 m m 1 4 6 7 m m 4 5 7 m m f r o n t d o o r o p e n i n g CANADA Figure 3 7 457MM FRONT DOOR OPENING 203MM 1114mm minimum 1254mm minimum 203MM Must extend 5...

Страница 10: ...Pipe 10 26 1 2 14 For Factory Alcove 6 diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A Chimney or Masonry chimney Maximum depth Alcove shall be no m...

Страница 11: ...20 Figure 3 13 Disclaimers Extended floor protection may be required for shallow installs follow floor protection requirements Full insertion installation may not allow use of the top load door depen...

Страница 12: ...chimney should Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the r...

Страница 13: ...g the diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when there are other facto...

Страница 14: ...d in these installations but manufacturers are no longer permitted to specify these on EPA Certified models The chimney system should be carefully reviewed and draft tested if possible prior to instal...

Страница 15: ...ys Chimney The chimney can be new or existing masonry or prefabricated and must meet the following minimum requirements specified in Section 4B C Chimney Systems Prefabricated Metal Chimney Must be mi...

Страница 16: ...lumber to fit into wall opening Inside opening of frame should be no less than 14 x 14 356 mm x 356 mm Figure 4 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wal...

Страница 17: ...e 6 152mm UL103 HT WARNING WARNING Asphyxiation Risk DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM May allow flue ga...

Страница 18: ...ll the Bottom Heat Shield NOTE TheBottomHeatShieldisrequiredinmostinstallations Refer to Floor Protection in the Dimensions and Clearances Section of this manual for further details 1 Align the bottom...

Страница 19: ...heavy stove gloves available near the stove Have special safety accessories e g Child Guard Screen available for use if small children will be in the home Fire Risk Do not leave the fire unattended wh...

Страница 20: ...e wall or flooring in your home 1 Remove all materials from packing box 2 Using a 2 Phillips screw driver attach the flex adapter to the appliance using 4 screws Figure 5 8 5 9 3 Floor Rear Installati...

Страница 21: ...rk Metalbestos DS or Security DL double wall connector or any listed double wall connector pipe 5 In Canada this appliance must be connected to a 6 152 mm factory built chimney conforming to CAN ULC 6...

Страница 22: ...mportant operating and maintenance instructions included Leave this manual with party responsible for use and operation Read understand and followtheseinstructions for safe installation and operation...

Отзывы: