DVBH7 Series Direct Vent Gas Fireplace

6

54D8001

Note ReGARDING VeNteD pRoDuctS

This product must be installed by a licensed plumber or gas fitter 

when installed within the Commonwealth of Massachusetts.
Any  residence  with  a  direct  vent  product  must  have  a  CO 

detector installed in the residence.
Installation  of  the  fireplace  or  vented  gas  log  in  the  State  of 

Massachusetts requires the damper to be permanently removed 

or welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a 

bedroom or bathroom in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have 

a T shutoff valve. 

Note ReGARDING VeNt FRee pRoDuctS

This product must be installed by a licensed plumber or gas fitter 

when installed within the Commonwealth of Massachusetts.
In  addition,  vent  free  products  may  not  be  installed  in  a 

bedroom or bathroom regardless of size or type in the State of 

Massachusetts.
Flex line installation must not exceed 36 inches and must have 

a T shutoff valve.

cARBoN moNoxIDe DetectoR RequIRemeNtS

() Revise  10.8.3  by  adding  the  following  additional 

requirements:
(a)  

For  all  side  wall  horizontally  vented  gas  fueled 

equipment installed in every dwelling, building or structure used 

in  whole  or  in  part  for  residential  purposes,  including  those 

owned or operated by the Commonwealth and where the side 

wall exhaust vent termination is less than seven (7) feet above 

finished  grade  in  the  area  of  the  venting,  including  but  not 

limited to decks and porches, the following requirements shall 

be satisfied:
1. 

Installation  of  carbon  monoxide  detectors. 

At  the  time 

of  installation  of  the  side  wall  horizontal  vented  gas  fueled 

equipment,  the  installing  plumber  or  gas  fitter  shall  observe 

that a hard wired carbon monoxide detector with an alarm and 

battery  back-up  is  installed  on  the  floor  level  where  the  gas 

equipment is to be installed. In addition, the installing plumber 

or gas fitter shall observe that a battery operated or hard wired 

carbon  monoxide  detector  with  an  alarm  is  installed  on  each 

additional level of the dwelling, building or structure served by 

the side wall horizontal vented gas fueled equipment. It shall be 

the responsibility of the property owner to secure the services of 

qualified licensed professionals for the installation of hard wired 

carbon monoxide detectors
 

a.  In the event that the side wall horizontally vented gas 

fueled equipment is installed in a crawl space or an attic, the 

hard  wired  carbon  monoxide  detector  with  alarm  and  battery 

back-up may be installed on the next adjacent floor level.
 

b.  In the event that the requirements of this subdivision 

can  not  be  met  at  the  time  of  completion  of  installation,  the 

owner shall have a period of thirty (30) days to comply with the 

above requirements; provided, however, that during said thirty 

(30) day period, a battery operated carbon monoxide detector 

with an alarm shall be installed.

massachusetts Residents only — please read and follow these special requirements

Approved  carbon  monoxide  Detectors.

 

Each  carbon 

monoxide detector as required in accordance with the above 

provisions shall comply with NFPA 70 and be ANSI/UL 034 

listed and IAS certified.
3. 

Signage.

  A  metal  or  plastic  identification  plate  shall  be 

permanently  mounted  to  the  exterior  of  the  building  at  a 

minimum height of eight (8) feet above grade directly in line with 

the exhaust vent terminal for the horizontally vented gas fueled 

heating appliance or equipment. The sign shall read, in print size 

no less than one-half (1/) inch in size, “GAS VENT DIRECTLY 

BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
4. 

Inspection.

 The state or local gas inspector of the side wall 

horizontally vented gas fueled equipment shall not approve the 

installation  unless,  upon  inspection,  the  inspector  observes 

carbon monoxide detectors and signage installed in accordance 

with the provisions of 48 CMR 5.08()(a)1 through 4.
(b) 

exemptions:

 The following equipment is exempt from 48 

CMR 5.08()(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not 

Required To Be Vented" in the most current edition of NFPA 54 

as adopted by the Board; and
.  Product Approved  side  wall  horizontally  vented  gas  fueled 

equipment  installed  in  a  room  or  structure  separate  from  the 

dwelling,  building  or  structure  used  in  whole  or  in  part  for 

residential purposes.
(c)  

manufacturer requirements — Gas equipment Venting 

System  provided.

 

When  the  manufacturer  of  Product 

Approved side wall horizontally vented gas equipment provides 

a  venting  system  design  or  venting  system  components  with 

the equipment, the instructions provided by the manufacturer 

for installation of the equipment and the venting system shall 

include:
1. Detailed instructions for the installation of the venting system 

design or the venting system components; and
. A complete parts list for the venting system design or venting 

system.
(d) 

manufacturer requirements — Gas equipment Venting 

System Not provided. 

When the manufacturer of a Product 

Approved  side  wall  horizontally  vented  gas  fueled  equipment 

does  not  provide  the  parts  for  venting  the  flue  gases,  but 

identifies “special venting systems,” the following requirements 

shall be satisfied by the manufacturer:
1.  The  referenced  "special  venting  system"  instructions  shall 

be  included  with  the  appliance  or  equipment  installation 

instructions; and
. The “special venting systems” shall be Product Approved by 

the Board, and the instructions for that system shall include a 

parts list and detailed installation instructions.
(e)  

A  copy  of  all  installation  instructions  for  all  Product 

Approved side wall horizontally vented gas fueled equipment, 

all  venting  instructions,  all  parts  lists  for  venting  instructions, 

and/or all venting design

Содержание 300DVBHNSC7

Страница 1: ...ppliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Aftermarket Completion of sale not for purpose of resale from the manufacturer DUE TO ...

Страница 2: ...ff Gas 30 Check Gas Pressure Signature Command System 31 Electrical Wiring SCS 31 Junction Box Wiring 32 Command Center Installation 32 Wall Switch Installation 32 Optional Fan Blower System SCS 34 BLOTSC 34 BLOT 35 FK 12 35 Operating Instructions SCS 36 Operating Instructions 37 To Turn Off Gas To Appliance 37 Signature Command System Operation 38 Glass Frame Removal 41 Final Installation 41 Bric...

Страница 3: ...s To prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions 4 Never install the fireplace in a recreational vehicle wh...

Страница 4: ...th glass door removed cracked or broken IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cycle Similar noises are found with your furnace heat exchanger or car engine IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplaces to give off some od...

Страница 5: ...ties having jurisdiction for installation at eleva tions above 4 500 feet 1 370 m GAS pressures Natural Propane LP Inlet Minimum 4 5 w c 11 0 w c Inlet Maximum 10 5 w c 13 0 w c Manifold Pressure 3 5 w c 10 0 w c Gas Specifications ORIFICE SIZE Max Input Min Input Orifice Model Fuel BTU h BTU h Size 300DVBHNV7 Nat 23 000 16 000 2 35 mm 400DVBHNV7 Nat 27 000 19 000 41 300DVBHNSC7 Nat 23 000 16 000 ...

Страница 6: ...4 mm 1Z v 32 mm L 1Z x 38 mm 2Z x 64 mm M 15 16 24 mm 15 16 24 mm N 5C 137 mm 6Z 156 mm O 31B 803 mm 34Z x 876 mm Framing Dimensions P 33Z x 851 mm 37Z x 953 mm Q 38 966 mm 41B 1057 mm R 13C v 349 mm 16Z x 419 mm S 55ZZ zn 1414 mm 60M 1546 mm T 39C 1000 mm 43Z zn 1094 mm U 27ZC zn 706 mm 30M zn 773 mm L C A B M 356O 856M J 5 8 1 2 548000 HBDV7 dims E D H 1 2 or 5 8 Min Rough Opening Height F G O I...

Страница 7: ...ll across a corner or use an exterior chase Refer to Figure 3 for suggested locations Location should be out of high traffic areas and away from furniture and draperies due to heat from appli ance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing Refer to Venting section found in this manual fo...

Страница 8: ...4 Clearances Ceiling Combustible Mantel 12 12 FP2581 mantelclearances Wall Stud Standoff FP2581 Top of Exhaust Louvers Side View 1 256O 3 4 156O 256O 45 FP2582 mantel side clearance Wall Combustible Material Area Side of Fire place Opening FP2582 Top View Figure 5 Mantel Clearances MANTEL CLEARANCES NOTE The combustible area above the facing must not protrude more than 3 4 from the facing If it do...

Страница 9: ...ng i e remote control wall switch and optional fan must be done prior to final finishing to avoid costly reconstruction Only noncombustible materials i e brick tile slate steel or other materials with a UL fire rating of Zero may be used to cover the black surface of the appliance A 300 F minimum adhesive may be used to attach facing materials to the black surface If joints between the finished wa...

Страница 10: ... Pipe Cover Flue Pipe Adapter FP1991 Figure 8 Remove 16 Screws from Flue Pipe Adapter and Flue Pipe Cover When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required 1 Remove the eight 8 screws securing the flue pipe adapter to the fireplace body Figure 8 2 Set the flue pipe adapter aside complete with the gasket Do not damage the gasket...

Страница 11: ...ply to the flexible venting Flex kits may not be modified Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer s approved flex to pipe adapters This may occur only if doing so does not violate any of the venting length height routing horizontal to vertical raito requirements or clearance considerations detailed in this manual Venting terminals shall n...

Страница 12: ...above the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15 cm for appliances to building or the combustion air inlet to any BTU h 3kW 12 30 cm for 10 000 BTU h 3kW 9 other appliances appliances 10 000 BTU h 3kW and 23 cm for appliances 10 000 100 ...

Страница 13: ...ntakes within 10 1 m of a termination cap must be a minimum of 3 914 mm below the termination cap 3 All gravity air intakes within 3 914 mm of a termination cap must be a minimum of 1 305 mm below the termination cap General Information Assembling Vent Pipes USA Installations The venting system must conform to local codes and or the current National Fuel Code ANSI Z223 1 NFPA 54 Only venting compo...

Страница 14: ...ermine the re lationship between the vertical and horizontal dimensions of the vent system 1 Determine the height of the center of the horizontal vent pipe exiting through the outer wall Using this di mension on the Sidewall Vent Graph Figure 15 locate the point intersecting with the slanted graph line 2 From the point of this intersection draw a vertical line to the bottom of the graph 3 Select t...

Страница 15: ... outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration If vertical rise is 7Z x feet or higher when top venting the clearance to combustibles is 1 on all sides of the horizontal run Vertical sections of this vent system require a minimum of 1 clearance to combustibles on all sides of the pipe FP2586 vent pipe clearance 3 1 1 3 1 1 3356 841 mm 29 6 753 mm...

Страница 16: ...ide frame center in the 9B x 9B vent opening VO584 100 Vent Opening 2 99 djt Vent Opening for Combustible Walls 9B 244 mm Min Fireplace Hearth Framing Detail Opening for Noncombustible Wall 7Z x 190 mm Fireplace Hearth FP2293 Figure 18 Locate vent opening on wall 9B 244 mm Min Step 3 Measure the horizontal length requirement for the venting including a 2 51 mm overlap i e from the elbow to the out...

Страница 17: ...enter ringed flue restrictor part 69D3006 must be installed onto the top edge of the firebox flue adapter To create this open center restrictor twist and break off the center rib of the supplied flue restrictor The installed part should appear similar to that show n in Fig ure 22 Since it is very important that the venting system maintain its balance be tween the combustion air intake and the flue...

Страница 18: ...installation Max 20 36 914 mm Max 36 914 mm Max FP1177 Figure 24 Maximum horizontal run with no rise Example According to the vent graph Page 14 the maximum horizontal vent length in a system with a 7Z x 2 3 m rise is 20 6 m and if a 90 elbow is required in the horizontal vent it must be reduced to 17 5 2 m In Figures 26 27 dimension A plus B must not be great er than 17 5 2 m The maximum number o...

Страница 19: ...ce Hearth FP2293 Figure 28 Locate vent opening on wall 9B 244 mm Min Step 2 Secure firestop to the inside frame center in the 9B x 9B vent opening Step 3 Place fireplace into position Measure the vertical height X required from the base of the flue collars to the center of the wall opening Figure 29 Step 4 Using appropriate length of pipe section s attach to fire place with three 3 screws Follow w...

Страница 20: ...e spring to approximately 15 381 mm wrap the spring around the pipe and interlock the ends of the spacer spring approximately 2 51 mm Measure 6C v 172 mm from the end of the pipe Place the next spring 5 127 mm from the previously installed spring Place the next spring 6 152 mm from the last spring Finally place the last spring 12 305 mm from the last spring installed Figure 31 Step 4 Install the 4...

Страница 21: ... seal is made around the vent pipe coming through the wall 5 Apply high temperature sealant caulking supplied around the 4 and 7 snorkel collars BG402a Top Vent Below grade installation Firestop Screws Minimum 4 Clearance Ground Window Well Gravel Drain Foundation Wall BG402a 24 610 mm Minimum Figure 33 Below Grade Installation Snorkel 7 Pipe 6 Slide the snorkel into the vent pipes and secure to t...

Страница 22: ...to the top edge of the firebox flue adapter Figure 37 1 Locate your fireplace 2 Plumb to center of the 4 flue collar from ceiling above and mark position 3 Cut opening equal to 9C v x 9C v 248 x 248 mm 4 Proceed to plumb for addi tional openings through the roof In all cases the open ing must provide a mini mum of 1 inch clearance to the vent pipe i e the hole must be at least 9C v x 9C v 248 x 24...

Страница 23: ...eiling support apps Typical Roof Support Application Typical Ceiling Support Application FP1184 Figure 39 Venting Supports 2 ft Min 2 ft Min X 12 H FP1971 Min chimney clearance Termination Vent Storm Collar Flashing Lowest Discharge Opening Concentric Vent Pipe 1 Minimum Clearance to Combustibles FP1971 Horizontal Overhang Figure 40 Minimum Chimney Clearance Roof Pitch H feet Flat to 6 12 1 0 Over...

Страница 24: ...gn certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equip ment shutoff valve from your dealer For propane LP connections only the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If y...

Страница 25: ...f the gas to the fireplace Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess seal ant in pipe could result in clogged burner system valves We recommend that you install a sediment trap drip leg in supply line as shown in Figure 43 Loc...

Страница 26: ...taking pressure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks Electrical Wiring This fireplace will work without any electrical supply Elec tricity is only needed to operate blower NOTE If installed in mobile home fireplace must be bolted securely to floor FP1979 Millivolt gas valve FP1979 Figure 44 Gas Pressure Check at Gas V...

Страница 27: ...l Figure 46 Blower Wiring Diagram Remote Wall mounted Switch A remote wall switch and up to fifteen 15 feet of 18 Ga wire may be used with this appliance Attach the wall switch in a junction box at the desired location on the wall Figure 45 Do not extend beyond the wall switch wire length provided NOTE Extended lengths of wire may cause the fireplace not to function properly Longer length of wire ...

Страница 28: ...alified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water for your safety read before lighting Lighting pilot for the first time initial li...

Страница 29: ...hat period of time when the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in serious injury WARNING 1 Depress and turn knob counterclockwise to pilot position 2 Depress fully and hold pilot gas knob Depress piezoigniterasmanytimesasneededtoignitepilot Keep k...

Страница 30: ...place This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 48 Lighting the burner Depress and turn the knob counterclockwise to the ON position Figure 49 It will take less than four 4 seconds for the burner to ignite Pilot position Depress and turn knob to pilot position to keep...

Страница 31: ...lectrical Wiring General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The 6 volt DC adapter plugs into the fireplace junction box A C power supply Four 4 AA batteries are used for back up during power outages 2 The Signature Command System can also be operated without A C power The system can run on four 4 AA batteries for approximately six 6 months under...

Страница 32: ...ll Do not extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction box to lower control area at bottom of fireplace Unplug the 12 cable from the com mand center Attach the connector to the pins from wire by pushing in to connector making sure to follow the co...

Страница 33: ...NG LP Plug in Connector Control Board to Command Center OFF LO LED ON HI Master Switch Command Center Optional Wall Switch Plug in Connector Stepper Motor to Control Board DC Power Green Ground Plug in Connector Control Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve ELECTRICAL INSTALLATION CAUTION Electrical connections should only be performedbyaqualified licensedelectrician Main power s...

Страница 34: ...the control will not work correctly WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service BLOTSC SIGNATURE COMMAND BLOWER Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection agai...

Страница 35: ...2 MANUAL BLOWER 1 This must be done before framing the fireplace When installing the FK 12 blower a wall switch control must be installed to control the blower 2 The fireplace power supply is wired through the blower wall switch and then brought to the fireplace junction box 3 The jumper clip on the plug receptacle must be re moved Figure 57 Use needlenose pliers to break off the jumper clip Junct...

Страница 36: ...e Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not func tion by hand do not try to repair it Call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water ...

Страница 37: ... smell gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will light 6 Once pilot flame is established the main burner flame will light automatically 7 If the pilot will not stay lit after several tries turn the master switch to OFF and call your service te...

Страница 38: ... X X X X Child Proof Lock out X X X X X LCD Backlight X X X X X Security Codes 16 X X X X X Countdown 6 hr Timer X X X Standard Thermostatic Control Mode X X X Smart Mode Thermostat Auto Flame Blower Modulation X X Three Brightness Settings for Lights X Three Speed Control for Blower X On Off Auxiliary X Programmable Timer to turn blower on and off X BATTERY INSTALLATION The Command Center uses fo...

Страница 39: ...3 seconds when the master switch Shutoff on the main burner is off RF Remote Receiver Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Learn Remote Hold the OFF button while turning on the master switch Transmitter Beep twice then press any handheld remote button 6 hour safety Press the ON button and OFF button simultaneously ON shutdown...

Страница 40: ...GREEN Flashes every 1 sec for 10 sec AC Power On GREEN solid Pressure Switch Failed Power Vent only One RED every 2 sec until manual reset Self Diagnostics Chart The Command Center has a self diagnostic LED enabling you to troubleshoot problems and potentially avoid a service call Please refer to the charts below for indicator reference Function Operation Power Up Flip the master switch to the ON ...

Страница 41: ...s toucher le panneau vitré brick installation 1 Remove glass door frame and log set 2 Remove the glass heat shield baffle and rear bracket 3 Install the center firebrick panel on the back wall first Stand firebrick panel straight up against the back of fire place with the bottom edge at bottom of inner firebox 4 Repeat Step 3 with the left and right side firebrick panels Secure the top of each sid...

Страница 42: ...nkle lava rocks around and in front of burner at bottom of firebox 3 Pull the rock wool apart into dime sized pieces or smaller Distribute one thin layer of rock wool over front ports and carryover ports Do not cover slots 400 or large holes 300 at rear of burner Figures 60 61 4 Place the logs on the burner Refer to Steps 4 10 Light the unit and after 15 minutes check burner flame and glow Adjust ...

Страница 43: ...ar Be sure the log is tilted backward When this log is in place it is seated sideways Figure 64 7b For 300 models place Left Log 3 by matching the notch on the side of the log with the protru sion on the rear log Set the left side of the log over the grate bar in the front by placing the notch of the log on the grate bar Make sure the log is tilted backward When this log is in place it is seated s...

Страница 44: ... holes Figure 66 10b For 300 models place Left Front Log 6 toward the left by sitting the notch on this log on the left tong of the grate and set the tips of the log on the burner Figure 66 LG749 HBDV Log 7 LG749 Right Front Twig 7 400DVBH Only Figure 67 11 For 400 models only place Right Front Twig 7 into place by hooking the end of the log on the second right tong of the grate and resting the ot...

Страница 45: ...ot into top andiron hole Slide clip over horizontal fireplace grate bar Figure 68 Adjust the screws and set the andirons over the cross bar of the grate between the two outer tongs on the right and left sides of the grate FP2593 andirons Top Andiron Hole Lower Andiron Hole Top Bracket Slot Lower Bracket Slot Horizontal Fireplace Grate Bar FP2593 Figure 68 Universal Andirons ...

Страница 46: ...ple or sensor and the other reaching to the main burner BURNER Inspect area around the injector Remove any lint or foreign material with a brush or vacuum Burner Flame The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation In normal operation at full rate and after operating for about 15 to 30 minutes the flame should be ye...

Страница 47: ...ri als may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposit on the inside of the glass should be cleaned off using a nontoxic non corrosive non abrasive mild cleaning solution Simply apply an adequate amount to the glass and wipe off with a damp cloth Af...

Страница 48: ...t the thermocouple connec tion at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter lead wire on the thermocouple copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15 mV replace pilot assembly B If thermocouple is producing more than 15 mV r...

Страница 49: ...adjust the pilot flame for maximum flame impingement on thermocouple A Check for flue product leak Replace defective pipe section B Check horizontal venting piping is running upward 1 4 per foot Do not run the pipe level or downward C Check for proper installation and freedom from debris or blockage A Install log set per the instructions Inspect the injector and air intake area Make sure this area...

Страница 50: ... through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check valve connections Check power supply go through A E Check grounding Go through B Go through C The sensor on the pilot is not in the flame pilot flame too small ACTION Re install batteries Change...

Страница 51: ...DVBH7 Series Direct Vent Gas Fireplace 54D8001 51 REPLACEMENT PARTS FIREBOX COMPONENTS 1 2 3 5 6 7 10 4 9 11 548001 DVBH parts ...

Страница 52: ...D0187 7 Standard Firebrick Left Tavern Brown 1 54D0285 54D0186 5 Standard Firebrick Center Cottage Red 1 26D7097 26D7105 6 Standard Firebrick Right Cottage Red 1 26D7096 26D7104 7 Standard Firebrick Left Cottage Red 1 26D7096 26D7103 8 Firebrick Walls Tavern Brown 1 FB300W10BTB FB400W10BTB 8 Firebrick Walls Cottage Red 1 FB300CRW FB400CRW 9 Brass Curved Design Trim 1 BRTK30C BRTK32C 9 Pewter Curve...

Страница 53: ...ty 300DVBH 400DVBH 1 Rear Log 1 1 54D5125 54D5040 2 Right Log 2 1 54D5126 54D5041 3 Left Log 3 1 54D5127 54D5042 4 Mid Top Log 4 1 54D5129 54D5043 5 Right Top Log 5 1 54D5128 54D5044 6 Left Front Log 6 1 54D5130 54D5045 7 Right Front Twig 7 1 54D5046 5 6 4 3 2 1 7 548000 HBDV DVBH logs parts ...

Страница 54: ...DVBH7 Series Direct Vent Gas Fireplace 54 54D8001 REPLACEMENT PARTS STANDING PILOT MILLIVOLT CONTROL 1 2C 2I 2T 2 4 5 6 3 8a 9 7 10 11 12 13 14 15 548000 HBDV DVBH millivolt parts 8b ...

Страница 55: ... 37D1069 2T Replacement Thermopile 1 37D1068 37D1068 37D1068 37D1068 3 Burner Tube 1 54D0288 54D0288 54D0194 54D0194 4 Flexhose w Shutoff Valve 1 23D6046 23D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 6 Piezo Ignitor 1 14D0503 14D0503 14D0503 14D0503 7 Injector 1 62D3006 20H3156 62D3004 33D5039 8 Burner Assy 1 54D5115 54D5115 54D5006 54D5006 9 Venturi 1 69D1119 69D1021 6...

Страница 56: ...DVBH7 Series Direct Vent Gas Fireplace 56 54D8001 REPLACEMENT PARTS 1 2 3 4 19 5 6 7 9 13 14 15 16 17 548000 HBDV7 SC parts 12 8a 8b SIGNATURE COMMAND SYSTEM ...

Страница 57: ...ire Valve Control not shown 1 80D0010 80D0010 80D0010 80D0010 11 Wire Command Ctr Control Box 2 1 80D0008 80D0008 80D0008 80D0008 not shown 12 A C Adapter 1 80D0041 80D0041 80D0041 80D0041 Accessories 13 Hand Held Remote Control w HI LO TimeR RMSC 14 Hand Held Remote Control w HI LO Tstat RTSC 15 Touch Screen Remote w Opt Light Auxiliary Blower Control TSFSC 16 Touch Screen Remote Hi Lo Timer TSMS...

Страница 58: ...4 Vent Pipe 4 pack 7TDVP24 4 36 Vent Pipe 7TDVP36 36 Vent Pipe 30 pack 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 pack 7TDVP48 30 Twist Lock Elbows 45 Elbow for Vertical Horizontal Offset 7TDV45 45 Elbow for Vertical Offsets 8 pack 7TDV45 8 90 Elbow for Vertical Horizontal Offset 7TDV90 90 Elbow for Vertical Horizontal Offset 8 pack 7TDV90 8 Shields and Supports 1 Firestop 7DV1FS 1 Attic Insu...

Страница 59: ...ion w Siding Shield and 2 ea Clamp Bands Twist Lock Pipe 20 Termination Pipe 8 pack 7TDVP20 8 10 16 Adjustable Termination Pipe 4 pack 7TDVPA 4 12 18 Adjustable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack 7TDVP12 4 24 Vent Pipe 4 pack 7TDVP24 4 36 Vent Pipe 7TDVP36 36 Vent Pipe 30 pack 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 ...

Страница 60: ... 24 904 4DT 4 4D24 3 6 36 Pipe Length galvanized 46DVA 36 903 4DT 36 4D36 3 6 48 Pipe Length galvanized 46DVA 48 902 4DT 48 4D48 4 6 81 2 Pipe Extension galvanized 46DVA 08A 4DT AJ 4 6 16 Pipe Extension galvanized 46DVA 16A 4DT AJ14 5 6 45 Elbow galvanized 46DVA E45 945 4DT EL45 4D45L 6 6 90 Elbow galvanized 46DVA E90 990 4DT EL90 4D90L 7 6 Adjustable Roof Flashing 0 12 6 12 46DVA F6 943 4DT AF6 4...

Страница 61: ...DVBH7 Series Direct Vent Gas Fireplace 54D8001 61 ...

Страница 62: ... comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please read and follow these special requirements 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ...

Страница 63: ...ns The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transport...

Страница 64: ... 70 9 300DVBHPV7 71 4 400DVBHPV7 70 7 300DVBHPSC7 75 7 400DVBHPSC7 74 0 Based on CSA P 4 1 09 Based on CSA P 4 1 09 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Selon CSA P 4 1 09 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com ...

Отзывы: