40-4 250 Service Hours
BC1000XL Brush Chipper Maintenance
C
ORROSION
I
NHIBITORS
- A
DD
TO
C
OOLANT
Add 3.5 oz (104 ml) of Fleetguard DCA4 to cooling system to restore corrosion inhibitors.
H
YDRAULIC
F
LUID
F
ILTER
- R
EPLACE
The hydraulic fluid filter (1) will need to be replaced earlier if the machine is in
storage for a long period of time, such as through the winter.
Step 1:
Thoroughly clean area around filter to keep contaminants out of the
hydraulic system.
Step 2:
Use a filter wrench to turn the filter counterclockwise and remove.
Step 3:
Clean the filter head surface.
Step 4:
Apply thin film of oil to gasket of new filter.
WARNING: Hot fluid under pressure can scald.
Allow engine to cool before opening radiator cap.
1
3_04
3_01