Calibration

The Vermason Portable Wrist Strap Tester is calibrated 

to NIST traceable standards. There are no user 

adjustments necessary. We recommend that calibration 

be performed annually using the Charleswater 

99090

 

Calibration Unit. It is a convenient product which allows 

the customer to perform NIST traceable calibration on 

single-wire personnel testers. The 

99090

 is designed 

to be used at the workstation, virtually eliminating 

downtime, verifying that the continuous monitor is 

operating within tolerances.
View technical bulletin 

PPE-5034.E

 for more information 

on the Charleswater 

99090

 Calibration Unit and 

instructions to calibrate the Portable Wrist Strap Tester.

Figure 3. Charleswater 

99090

 Calibration Unit

Specifications

Power Supply

9 V Alkaline Battery

Operating Temperature 32 °F to 104 °F (0 to 40 °C)
Test Limits

750 kilohms to 35 megohms

Test Voltage

4 VDC

Dimensions

3.6" x 2.6" x 1.1"

(91 mm x 66 mm x 28 mm)

Weight

4 oz (113 g)