Содержание Stagemaker B12PRMLV-C1

Страница 1: ...STAGEMAKER KONTROLLER USERS MANUAL CONTROLLERS model B SC R FL for STAGEMAKER SM CHAIN HOISTS Version A direct control Version B low voltage control Version D low voltage control BGV C1 2004 07 GB...

Страница 2: ...36 EEG 91 263 EEG 92 31EEG 93 68 EEG As well as harmonised norms in particular EN292 chapter 1 and 2 safety of machines Applied technical standards and specifications in particular IEC 34 1 Rotating e...

Страница 3: ...NTENT chapter description page 1 Introduction 4 2 What to do What not to do 6 3 Guarantee 8 4 Identification 9 5 Functional description 11 6 Cable selection table 17 7 Cable connection tables 18 8 Tro...

Страница 4: ...fficial APAVE institute They offer a maximum flexibility durability and safety There are three series of controllers version A Economical units with direct selection with or without remote version B C...

Страница 5: ...addition Remote control by means of toggle switches on a control box with flexible cable and multi connector All functions with LED indicators allows safe operation even in the dark Manual On Off phas...

Страница 6: ...ng the operation to press the emergency stop button This makes all functions inactive Before operation check that the load is correctly fastened and installed on the hook The hook safety catches shoul...

Страница 7: ...e controller if your physical condition does not allow it Never use the controller if it is in bad condition Never use suspected spare parts or parts whose origin is not known Do not subject the contr...

Страница 8: ...ised party or without our prior agreement The guarantee only applies for original factory installed spare parts For the duration of the guarantee the vendor undertakes to replace or repair free of cha...

Страница 9: ...flight case A Harting 16p FL4PLV 4 Low voltage 48Vac No Vertical flight case B1 B2 2 x CEE plug 4p FL8PLV 8 Low voltage 48Vac No Vertical flight case B1 B2 2 x CEE plug 4p FL12PLV 12 Low voltage 48Vac...

Страница 10: ...t Front rear Front Green RUN button Front front Front Main secondary fuses Front front Front Thermal protection per group of four n a front Front Auxiliary output 16Amp CE 4 pole not switched n a n a...

Страница 11: ...pper or lower mode Release the emergency switch by turning anti clockwise Push the RUN button to activate the pre selected hoists Check if the hoist direction matches the selected mode If not reverse...

Страница 12: ...1 6 A I O STA R T MO TO R 1 4 MO TO R 1 8 FUSE FUSE FUSE L1 L 2 L 3 ST A R T G EN ER A L Telem ecanique OFF STOP START 1 6 1 4 1 2 1 Test Telem ecanique OF F STOP ST ART 1 6 1 4 1 2 1 Tes t VERLINDE t...

Страница 13: ...RTING 3 1 Power input 3 X4 0 0 V N T 1 6 A I O STA R T MO TO R 1 4 M O TO R 1 8 FUSE FUSE FUSE L1 L 2 L3 STA R T G EN ER A L Telem ecanique OFF STOP START 1 6 1 4 1 2 1 Test Telem ecanique OFF STOP ST...

Страница 14: ...T O R 1 3 M O T O R 5 8 M O T O R 1 4 R E M O T E R E M O T E F E S T I O S T A R T 4 8 V A C 3 1 4 2 Telemecanique OFF STOP START 1 6 1 4 1 2 1 Test PG21 MOTOR1 MOTOR2 MOTOR3 MOTOR4 MOTOR8 MOTOR7 MOT...

Страница 15: ...AGEMAKER CONTROLLERS 2004 07 GB 13 R model CONTROLLERS version D 1 Multy cables 10 or 20 M code No 5229261 or 5229262 HARTING HARTING HARTING Power input 1 HARTING HARTING HARTING Controller R8PRMLV C...

Страница 16: ...0 M code No 5229261 or 5229262 HARTING HARTING Power input 1 HARTING HARTING HARTING HARTING B2PRMLV C1 2004 07 GB 14 O I POWERON PHASEN FAILURE M O T O R 1 M O T O R 2 R E M O T E P O W E R S U P P L...

Страница 17: ...14 d 2 5mm sections 400V 50Hz 230V 50Hz L max m In Max A L max m In Max A SM1 255 125 1 4 80 40 2 5 SM5 110 55 3 2 45 20 4 5 SM10 75 35 1 75 25 7 SM25 45 7 75 14 Limitations Cable with different secti...

Страница 18: ...e 6 L3 black 7 GND yellow green 8 L1 brown 9 L2 blue 10 L3 black 11 GND yellow green 12 L1 brown 13 L2 blue 14 L3 black 15 GND yellow green 16 PE Version B2 single control cable with CEE plug for cont...

Страница 19: ...al 8 8 pink action 2 9 purple by pass 4 10 red signal 8 11 grey action 3 12 grey white 13 brown white 0Volt 9 14 blue white 15 red white 16 black white PE yellow green Earth PE Note These tables shoul...

Страница 20: ...button is pressed turn anticlockwise and pull pre selection switch settings up or down mode output cables connected Warning Before going in the panel it self or removing the top plate first disconnec...

Отзывы: