Expansion Storage Shelf Expansion Service Action Allowed canister LEDs
3
If the Service Allowed LED is not blue, access the appliance shell menu.
You can use the Support > ServiceAllowed command to turn on the blue light. If you cannot turn
on the light, contact Veritas Technical Support.
4
Label the cables from the canister that you plan to remove.
•
On a RAID canister, label the FC cables that connect to the appliance. Label the SAS cables
(if present) that connect to the Expansion shelf.
•
On an Expansion canister, label the SAS cables that connect to the Primary shelf.
5
Remove the cables from the canister that you need to replace.
•
From a RAID canister, remove the FC cables that connect to the appliance. Remove the SAS
cables (if present) that connect to the Expansion shelf. Remove any Ethernet or other FC
cables.
•
From an Expansion canister, remove the SAS cables that connect to the Primary shelf.
6
Do not remove the power cords.
7
Remove the FC SFPs from the RAID canister. The Expansion canister does not have any SFPs.
•
Flip up the metal handle on the SFP.
6
HSP 133 RAID or Expansion canister replacement