Use the SFPs that you removed before you removed the original RAID canister.
•
Insert an SFP into an FC port. You should not need to use the handle.
4
On the RAID or Expansion canisters, reconnect all of the cables that were removed from the
original canister.
5
Bring the replacement RAID canister online. If the canister does not come online, contact Veritas
Technical Support.
6
Look at the Service Action Required LEDs and Service Action Allowed LEDs.
•
If all of the Service Action
Required
LEDs are off, the procedure is completed.
•
If any of the storage shelf Service Action Required LEDs are on, or if the RAID canister Service
Action Required LED is on – Check that the canister has been installed correctly and that all
of the cables are installed correctly. Reinstall the canister, if necessary.
7
Look at the seven segment displays on the new canister.
•
The display on the RAID canister should read “99.”
Note:
It can take up to 10 minutes for the canister to become operational. If after 10 minutes,
the display is a number other than 99, you should escalate the issue.
•
The display on the Expansion canister should read “00.”
Note:
It can take up to two minutes for the Expansion canister to become operational. If after
two minutes, the display is a number other than 00, you should escalate the issue.
11
HSP 133 RAID or Expansion canister replacement