Table 1-1
Veritas 5340 Appliance system specifications
(continued)
Veritas 5340 Appliance system
Technical
Specification
Compute node:
■
Specification: IEC-60320-C14 to IEC-60320-C13, 15A/250V,
Black, 4ft
The IEC-60320-C14 plugs into a Power Distribution Unit. The
IEC-60320-C13 plugs into an appliance or storage shelf power
supply.
Note:
If your power distribution unit is not compatible with the
IEC-60320-C14 plug, Veritas recommends that you purchase
your power cable locally. Make sure the power cable meets or
exceed the indicated power rating.
See
on page 68.
Storage shelf:
■
Specification: IEC-60320-C20 to IEC-60320-C19, 20A/250V,
Black, 4ft
The IEC-60320-C20 plugs into a Power Distribution Unit (PDU)
on a rack. The IEC-60320-C19 plugs into an appliance or a
storage shelf power supply.
Note:
If your power distribution unit is not compatible with the
IEC-60320-C20 plug, Veritas recommends that you purchase
your power cable locally. Make sure the power cable meets or
exceed the indicated power rating.
See
on page 68.
AC power cable
> 90%
Power Factor
Typical:
■
14,408 BTU/hour
Maximum:
■
19,267 BTU/hour
System cooling
requirement (heat
dissipation)
(Appliance with
maximum storage
shelves attached)
200 – 240 VAC
Operating voltage
50/60 Hz
AC Frequency range
Each Appliance compute node: 90% +
5U84 Primary/Expansion Storage Shelf: 89% +
Power conversion
efficiency
11
About the Veritas 5340 Appliance
Features and components of the appliance