E54C3C Installation Guide

E54C3C Installation Guide

Configuration (cont.)

Configuration Menu 

All parameters in the configuration menu are modified in one of two ways.

1.  Select a value from a pre-set list:

  use the down button to scroll through the parameter values until the desired value is 

reached. Press OK to confirm the selected value.

2.  Modify a numerical value: 

 the digit on the far right is selected first. Use the down button to modify the selected digit. 

Press OK to move to the next digit. Repeat for all available digits, then press OK to confirm the selected value.

To cancel the current entry, press the ESC button. This cancels the modification and the screen reverts to the last saved value.

A - Cancel and return to the 

previous screen

B - Reset the settings to their 

defaults, except for the 

password, and restart the 

meter.

Wiring

Wiring\Type

Wiring\VT

Wiring\CT

Wiring

Save settings?

OK

3PH4W

1PH2W L-N

...

Direct-NoPT

Wye(3PTs)

...

1 CT on I1

2 CTs on I1, I3

...

CT & VT Ratio

..\CT Secondary

..\CT Primary

..\VT Secondary

..\VT Primary

5

1

100

110

...

1

2 ...

0 - 99999

CT & VT Ratio

Save settings?

1

2 ...

0 - 9999999

Frequency

Frequency

50

60

Frequency

Save settings?

Date

Date

Date

Save settings?

1

2 ...

DD-MM-YYYY

Time

Time

Time

Save settings?

1

2 ...

hh:mm

T3 Start = T1 Start
T4 Start = T2 Start

Multi- Tariffs

..\Control Mode

..\Schedule

..\T1 Start

Multi Tariffs

Save settings?

Disable

by Digital Input

by Communications

by Internal Clock

..\T2 Start

1

2 ...

hh:mm

1

2 ...

hh:mm

by 2 Tariffs

by 3 Tariffs

...

Overload Alarm

..\Alarm

Disable

Enable

..\Pick Up Value

Overload Alarm

Save settings?

1

2 ...

0 - 9999999

Contrast

Contrast

Contrast

Save settings?

1

2

...

Com.Protection

Com.Protection

Com.Protection

Save settings?

Enable

Disable

Password

Password

Password

Save settings?

1

2 ...

1 - 9999

Reset Config

Reset Config

Confirm & Reboot?

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

Digital Input

..\DI Function

..\In. Pulse Const.

Digital Input

Save settings?

Input Status

Tariff Control

Partial Reset

Input Metering

1

2 ...

1 - 99999

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

Digital Output

..\DO Function

..\Pulse Constant

Digital Output

Save settings?

Disable

for Alarm

for Pulse

OK

OK

OK

OK

0.01

0.1

...

..\Pulse Width

100

200

...

OK

Communication

..\Slave Address

..\Baud Rate

1

2 ...

1-247

OK

OK

Communication

OK

OK

19200

38400

...

Save settings?

..\Parity

OK

ODD

EVEN

NONE

ESC

ESC

ESC

ESC

After performing basic configuration, navigate to the real-time data screens and verify that the readings are correct.

The terms “VT” (voltage transformer) and “PT” (potential transformer) are used interchangeably.

Troubleshooting

Code

Description

Solution

-

LCD display is not visible.

Check and adjust LCD contrast.

-

Push buttons do not function.

Restart the energy meter by powering off and powering on 

again.

101

Metering stops due to an EEPROM error. Press 

OK

 to 

display total energy consumption.

Enter configuration mode and implement Reset Config.

102

Metering stops due to a lack of a calibration table. Press 

OK

 to display total energy consumption.

Enter configuration mode and implement Reset Config.

201

Metering continues. Mismatch between frequency 

settings and frequency measurements.

Correct the frequency settings according to the nominal 

frequency of the power system.

202

Metering continues. Mismatch between wiring settings 

and wiring inputs.

Correct the wiring settings according to the wiring inputs.

203

Metering continues. Phase sequence reversed.

Check the wire connections and correct the wiring settings if 

needed.

204

Metering continues. Total active energy negative due to 

incorrect voltage and current conditions.

Check wire connections.

205

Metering continues. Date and Time have been reset due to 

a loss of power.

Set the Date and Time.

206

Metering continues. Pulse is missing due to overload on 

energy pulse output.

Check the energy pulse output settings.

207

Metering continues. Abnormal internal clock function.

Restart the energy meter by powering off and powering on 

again then reset the date and time.

Multi-Tariff Feature

The multi-tariff feature allows the meter to categorize energy consumption by peak times vs. off-peak times and by weekdays 
vs. weekends. The following table illustrates how the tariffs operate according to the tariff selection (2, 3 or 4 tariffs). These 
tariffs are stored in four different registers: T1, T2, T3, and T4.

Weekday

Weekend

24 H

T1

T2

24 H

T1

T2

24 H

T1

T2

24 H

T1

T2

24 H

T3

24 H

T3

T4

2 Tariffs

3 Tariffs

4 Tariffs

ZL0131-0G              Page 7 of 8                          ©2018 Veris Industries   USA 800.354.8556 or +1.503.598.4564  / [email protected]                                                          0818 

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of  Veris Industries, L.L.C. in the USA and/or other countries.

Other companies’ trademarks are hereby acknowledged to belong to their respective owners.

EAV71194-04

ZL0131-0G              Page 8 of 8                          ©2018 Veris Industries   USA 800.354.8556 or +1.503.598.4564  / [email protected]                                                          0818 

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of  Veris Industries, L.L.C. in the USA and/or other countries.

Other companies’ trademarks are hereby acknowledged to belong to their respective owners.

EAV71194-04

Отзывы: