F: Separation Between Devices Using Adjacent Channels
68
Verint Video Intelligence Solutions
6. When the survey is complete, visualize the report. For example:
This report provides the signal levels between device A1 and the other five devices in
the network.
The lowest signal in Cell A is -75 (S1) and the highest signal in Cell B is -45 (S2). The
result of S2 - S1 (-45 - -75) is 30. Since the margin is higher than 25 dB, there will be
interference issues.
Devices found on channel 3
Devices found on channel 6
Device name
Signal level
Cell B
Cell A
A3
A2
B3
B2
A1
-75
-45
-60
B1
-70
-75