Continue for all models as follows :-
Whilst the fire box is still in position, decide which side the gas supply is to enter
the fire from. If concealed pipe work is required plan the pipe run to enter the fire
box through one of the openings in the sides or rear of the fire box below the
fuelbed support panel and connect to the isolating / inlet elbow. The gas
connection to the appliance should be made to the isolating / inlet elbow using
8mm rigid tubing. There must be no soldered joints within the firebox. See fig. 11
& 12 below for suggested concealed pipe layouts.
Fig. 11
Fig. 12
Note : Before breaking into the gas supply a pressure drop test should be
carried out to establish that the existing pipework is sound.
Carefully withdraw the fire box from the opening to enable the gas supply and fire
fixing to be completed.
14
Firebox
Fireplace
Builders
Opening
Gas Supply
Firebox
Approx.
40mm
Fireplace
Gas Supply
Approx.
40mm
Builders
Opening