Verine Marcello NBFP00RN Скачать руководство пользователя страница 5

 

 

Decorative Fascia Panel

  

 

This  appliance  must  be  installed  with  the  fascia  panel  set  supplied.  This  panel 
allow the passage of air for convection and for the cooling of the control system. 
It must be installed as described in these instructions.  The fire should never be 
left  running  with  this  fascia  panel  dropped  down.    This  will  overheat  both  the 
fascia and glass window. 

Ventilation

 

 

This  is  a  room-sealed  appliance;  therefore,  there  is  no  requirement  for  purpose 
made ventilation into the room containing the fire. 

The  appliance  is  designed  for  use  with  both  natural  gas  and  propane.  The  two 
gases  require  different  burners  that  are  not  interchangeable  between  the 
different gas types. 

  

The appliance must not be installed in a room containing a bath or shower or in 
a private garage. 

Shelf 

 

If  a  shelf  made  of  combustible  material  is  to  be  fixed  to  the  wall  above  the 
appliance a space of at least 150mm must be left between the top of the fascia 
and the underside of the shelf. 

THE HEARTH

 (Appliances in floor level fireplaces) 

Where the appliance is fitted in a floor level builders opening, floor level fireplace 
recess or floor level flue box, the hearth shall: 

a, 

Extend through the whole base of the builders opening, fireplace recess or 
beneath the flue box. 

 

b, 

Project at least 275mm in front of the glass window panel.  

c, 

Project at least 150mm beyond each side of the edge of the glass window 
panel. or if there is a non-combustible wall within 150mm of glass panel, 
up to that wall. 

 

d, 

Have a thickness of not less than 12mm and a minimum height of 50mm 
along its front and side edges. 

 

Hole-in-the-wall installations 

Where  the  appliance  is  installed  in  a  hole-in-the-wall  fireplace,  a  hearth  as 
previously  detailed  for  floor  level  fireplaces  shall  be  fitted  on  the  floor  beneath 
the hole so as to protect combustible material from radiant heat.  

a, 

If  a  hearth  is  not  to  be  used,  so  as  to  maintain  a  minimal  and 
contemporary styling, the appliance must be installed so that the base of 
the  appliance  is  at  least  200mm  vertically  above  any  carpet  or  floor 
covering.  

b, 

Where no hearth is to be fitted 

consideration

 should be given to fixing a 

tactile  separator  to  protect  young  children,  the  elderly  and  the  infirm.  A 
tactile  separator  can  be  in  the  form  of  a  fender,  kerb,  hearth,  shelf  or 
horizontal bar all made from non combustible material and fixed not less 
than  50mm  &  not  more  than  1000mm  above  the  floor  level.  It  should  be 
positioned not less than 275mm in front of and 150mm beyond the edge 
of the window glass.  

Содержание Marcello NBFP00RN

Страница 1: ...ced Flue Convector MODEL NUMBERS NBFP00RN NBFP00RP INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS D...

Страница 2: ...ourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall directly above th...

Страница 3: ...lations APPLIANCE DATA NBFP00RN NBFP00RP GAS TYPE NATURAL GAS PROPANE SUPPLY PRESSURE 20mb 37mb HEAT INPUT 4 5 kW Gross 4 25kW Gross GAS RATE 0 43m 3 h 0 16 m 3 h 305g hr INJECTOR SIZE 1 6 mm 1 05 mm...

Страница 4: ...structions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM DISTANCE A Directly below an opening air brick or window etc 300mm B Above an opening air brick opening windows...

Страница 5: ...earth shall a Extend through the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond...

Страница 6: ...the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Before starting the installation remove th...

Страница 7: ...are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill drill holes through the holes in the flue outer ring and into the outer flue tu...

Страница 8: ...porally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole already cut in the inner leaf of the ca...

Страница 9: ...tor box flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the...

Страница 10: ...the gas supply must be turned on by removing the cap from the isolator fitting and unscrewing the plug all the way out Replace the cap making sure that the tab engages with the slot in the top of the...

Страница 11: ...11 4 Advise the importance of having the appliance serviced on an annual basis...

Страница 12: ...results from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reas...

Страница 13: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Страница 14: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Страница 15: ...eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a CORGI registered engineer This is the basic procedure...

Страница 16: ...it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS 12 Replac...

Страница 17: ...placement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Pilot Burner LPG Model CV 104513 In...

Страница 18: ...3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 19: ...19 B 111770 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Отзывы: