Verine Marcello NBFP00RN Скачать руководство пользователя страница 1

 

 

 

 

 

Marcello 

 
 
 
 
 

Balanced Flue Convector 

 

MODEL NUMBERS:  NBFP00RN, NBFP00RP 

 

 

 

 

 

 

INSTALLATION, USER AND

 

SERVICING INSTRUCTIONS

 

 

THESE INSTRUCTIONS MUST REMAIN WITH THE USER 

 

 

 

 

 

 

 

 

 

 

THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE

 

0087 

Содержание Marcello NBFP00RN

Страница 1: ...ced Flue Convector MODEL NUMBERS NBFP00RN NBFP00RP INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS D...

Страница 2: ...ourself product and it must be installed by a competent person 2 The Installation Instructions must be adhered to without exception 3 The heat from this appliance will cause the wall directly above th...

Страница 3: ...lations APPLIANCE DATA NBFP00RN NBFP00RP GAS TYPE NATURAL GAS PROPANE SUPPLY PRESSURE 20mb 37mb HEAT INPUT 4 5 kW Gross 4 25kW Gross GAS RATE 0 43m 3 h 0 16 m 3 h 305g hr INJECTOR SIZE 1 6 mm 1 05 mm...

Страница 4: ...structions and ventilation openings are shown below DIMENSION TERMINAL POSITION MINIMUM DISTANCE A Directly below an opening air brick or window etc 300mm B Above an opening air brick opening windows...

Страница 5: ...earth shall a Extend through the whole base of the builders opening fireplace recess or beneath the flue box b Project at least 275mm in front of the glass window panel c Project at least 150mm beyond...

Страница 6: ...the dwelling Fitting This appliance can be installed either by being fixed directly on to the surface or it can be inset into the inner leaf of a cavity wall Before starting the installation remove th...

Страница 7: ...are not concentric and that the inner tube is positioned towards the top of the outer tube Using a 3 5mm diameter drill drill holes through the holes in the flue outer ring and into the outer flue tu...

Страница 8: ...porally screw the convector box to the inner wall plate with four M5 screws Place the convector box over the protruding flue pipe and push the box into the hole already cut in the inner leaf of the ca...

Страница 9: ...tor box flange Fix the heat exchanger through the convector box flanges to the inner fascia using the M5 bolts supplied Replace the self tapping screws that secure the flue to the wall plate Seal the...

Страница 10: ...the gas supply must be turned on by removing the cap from the isolator fitting and unscrewing the plug all the way out Replace the cap making sure that the tab engages with the slot in the top of the...

Страница 11: ...11 4 Advise the importance of having the appliance serviced on an annual basis...

Страница 12: ...results from your fire we recommend that it be serviced annually 7 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place 8 If you have any reas...

Страница 13: ...ger period d Depress control knob A slightly and turn anti clockwise to the ON position The main burner will not operate until this is done The main burner may light depending on the position of Contr...

Страница 14: ...the DOWN button on the handset Release when the flame is at the desired height or has gone out Once again the electric motor should be heard moving Control Knob B Cleaning the fire Ensure that the app...

Страница 15: ...eating or drinking in the work area and that hands are washed before eating or drinking The appliance should be serviced at least once a year by a CORGI registered engineer This is the basic procedure...

Страница 16: ...it and secure with the eight nuts Tighten the nuts evenly Stubborn marks can be removed with steel wool and detergent AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS 12 Replac...

Страница 17: ...placement the parts list is as follows Part Description Part Number Motorised valve CV 104103 Remote hand control Receiver CV 104413 Pilot Burner NG Model CV 104506 Pilot Burner LPG Model CV 104513 In...

Страница 18: ...3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 19: ...19 B 111770 Issue 2 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com...

Отзывы: