Page 6 of 14
This appliance may be connected to an ‘Exhausto’ power flue system where no
suitable chimney is available. Details may obtained from Exhausto Ltd., Unit 3,
Lancaster Court, Coronation Road, Cressex Business Park, High Wycombe, HP12
3TD Tel; 01494 465166. The ‘Post Purge’ option
must
be selected when setting up
the system.
6
Gather
The gather supplied must be used to connect the appliance to the chimney. The
dimensions of the gather are given in Figure 3. Check the thickness of any masonry
plus the decorative infill panel, if used, against the distance shown between the rear
of the flange and the front of the gather. The gather should be installed, connected
to the flue and temporarily lodged in position before the firebox is finally placed in
position. After the firebox is properly positioned the gather can be drawn down to
the firebox by gripping the handles provided inside the gather and secured with
seven self tapping screws which pass through the top of the firebox into the gather.
Please note that the gather and firebox are not structural items and the flue should
be supported and not rest entirely on the gather.
7
Ventilation.
United Kingdom; The room containing the appliance must have a permanent air
vent with an effective open area of at least 100 cm
2
. The vent must be either direct
to outside air or to an adjacent room having a permanent vent of the same area.
Eire; Ventilation should be installed in accordance with the current edition of
I.S.813 ‘Domestic Gas Installations’ and the current Building Regulations.
8
Legs.
150mm tall legs with adjustable feet are supplied which can be used to raise the
appliance from an existing hearth. The legs are supplied loose and are fixed to the
lower firebox with two 8mm bolts. The legs do not have to be used. The appliance
may be raised using masonry blockwork if this is more convenient but allowance
must be made for the power supply unit which is suspended underneath the lower
firebox.
9
Power Supply Unit.
The remotely controlled gas valve fitted to this appliance operates via a 6 volt DC
power supply unit. The power supply unit supplied with the appliance must be
connected to a 220 – 240 volt AC mains supply. The power supply unit is supplied
already mounted to the plate that closes off the opening in the bottom of the lower
firebox. After the lower firebox has been installed the mains supply lead should be
lead to the opening in the lower firebox. The lead can then be plugged into the power
supply unit, the 6volt d.c. lead can be threaded through its grommet in the closure
FIGURE 3