background image

Page 12 of 14 

Adjusting the Flame Height

  

 

To  lower  the  flame  height  press  and  hold  the DOWN  BUTTON  until  the  flame  is  at 
the desired height. To turn the main burner off and just leave the pilot burner alight 
continue to press and hold the down button until the main burner does out. To re-
light the main burner press and hold the SMALL BUTTON and UP BUTTON together 
until the flame is at the desired height. 

Turning the Fire OFF 

 

To turn the fire off but leave the pilot burner alight press the DOWN BUTTON until 
the main burner does out. To turn the fire completely off press the OFF button.    

 

Manual Off Facility

 

 

If,  whilst  the  fire  is  alight,  the  handset  control  is  lost  or  its  battery  becomes 
discharged  the  fire  can  be  turned  off  by  switching  the  appliance  ON/OFF  switch 
(located  just  behind  the  signal  receiver  which  is  situated  just  in  front  of  the  right 
hand side of the main burner) to the OFF position which is indicated by the symbol 

O

.  Caution  should  be  exercised  as  this  switch  is  situated  quite  close  to  the  pilot 

flame.  Switch  back  to  the  ON  position  to  allow  the  appliance  to  be  re-lit  when 
required. 

Cleaning the fire

 

1

 

Ensure that the fire is cold before undertaking any cleaning.  Remember that heat is 
retained for some time after the fire is switched off.  In normal use your fire requires 
only  minimal  cleaning.    Some  soot  may  form  on  any  ceramic  pieces  placed  in  the 
flames but this is generally harmless unless an excessive amount is deposited. 

2

 

If  large  pieces  of  debris  are  found  in  the  fire,  sufficient  to  alter  the  appearance  or 
operation  of  the  appliance,  the  chimney  /  flue  should  be  inspected  and  the 
appliance serviced before further use. 

In any event, the chimney should be checked annually to ensure continued clearance of the 
combustion products and that there is no excessive build-up of soot.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Carmelo 1150 NHWV00RN NG

Страница 1: ...NSTRUCTIONS THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE Model No NHWV00RN for use with natural gas G20 at a supply pressure of 20mbar Model No NHWV00RP for use with propane G31...

Страница 2: ...D OF 2nd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signe...

Страница 3: ...illage 9 Briefing the User 10 USERS GUIDE 10 Useful tips recommendations 10 Operation of the fire 11 Lighting the Appliance 11 Cleaning the fire 12 SERVICING MAINTENANCE 13 Spares Parts list 14 Import...

Страница 4: ...TS Fitting the Appliance 1a United Kingdom The law demands that all gas appliances are installed by a qualified installer in accordance with the current GAS SAFETY INSTALLATION AND USE REGULATIONS The...

Страница 5: ...l at least 12mm in thickness In order to provide a tactile warning to persons approaching the naked flames we strongly recommend that an external hearth or a shelf mounted on the wall beneath the appl...

Страница 6: ...g the appliance must have a permanent air vent with an effective open area of at least 100 cm2 The vent must be either direct to outside air or to an adjacent room having a permanent vent of the same...

Страница 7: ...orizontal and non combustible If the fire opening is to be elevated the base under the firebox will have to be raised to suit and the masonry above the firebox altered to accommodate the gather 4 The...

Страница 8: ...ct the gas supply and remove the control mount 10 The space in front of the lower part of the firebox can be filled with masonry and made good or an infill panel fitted Slide the upper part of the fir...

Страница 9: ...y driftwood 2 The refractory pieces may be arranged as desired If the objects on the fire bed become excessively covered in soot they should be removed from the fire or placed in another position COMM...

Страница 10: ...s with any fire certain components will become hot in use Care should be exercised when approaching the appliance when it is hot We also recommend that a fireguard conforming to BS 6539 or BS 6778 be...

Страница 11: ...tery by pushing the connector on to the terminals Make sure the battery is connected correctly Replace the access cover 2 Using the Handset When using the handset make sure that it is pointed at the i...

Страница 12: ...ceiver which is situated just in front of the right hand side of the main burner to the OFF position which is indicated by the symbol O Caution should be exercised as this switch is situated quite clo...

Страница 13: ...operate the spark generator and observe that the spark is satisfactory 5 Lay the control mount assembly on a flat surface and remove clean and replace the main injector 6 Any soot or debris should be...

Страница 14: ...umber Electronic Control Remote Handset G6R PISOA5A0S5 Motorised Control Valve GV60M1C5A0D5K10L Oxypilot NG models Seagas P4 61 Oxypilot LPG models Seagas P4 58 B 112070 Issue 3 BFM Europe Limited Tre...

Отзывы: