Remote Unit
If the remote unit is a Verilink FSx product, and FrameStart Auto Discovery is
enabled, this field displays the first three digits of the unit ID configured on
the remote end of this DLCI.
Values: 000
−
999
Default: 000
Round Trip Delay Size
(bytes)
Specifies the frame size (in bytes) of packets making the round trip. If the
Round Trip Delay Size is not configured, the Frame Relay Details values will
be used.
Round Trip Delay Rate
(secs)
Specifies the rate (in seconds) at which Round Trip Delay packets are sent. If
the Round Trip Delay Rate is not configured, the Frame Relay Details values
will be used.
DLCI Status Table
The bottom portion of the screen shows a table detailing the actual status of
DLCI and alarm threshold information as follows:
Status
If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”
Values: Active, Inactive
Default: Inactive
Receiving FECN/
BECN
When a frame is received with congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without congestion bit
set.
Values: Yes, No
Default: No
CIR Threshold
Sets the Tx over CIR alarm threshold. This threshold is the number of bits per
second in excess of CIR during a 15-minute interval. Setting this field to “0”
(zero) disables the alarm.
CIR Alarm
Reports if the Tx over CIR threshold has been exceeded.
Bits Over Be Threshold
Sets the Tx over excess burst alarm threshold. This threshold is the number of
bits per second in excess of CIR + Be during a 15-minute interval. Setting
this field to “0” (zero) disables the alarm.
Bits Over Be Alarm
Reports if the Tx over Be threshold has been exceeded.
Congestion Threshold
Sets the Rx Congestion alarm threshold. This threshold is the number of
frames received with BECN/FECN. Setting this field to “0” (zero) disables
the alarm.
Congestion Alarm
Reports if the Rx Congestion threshold has been exceeded.
Содержание Wansuite 5230
Страница 1: ...i WANsuite 5260 5230 Reference Manual April 2002 34 00304 F...
Страница 4: ...iv W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 30: ...2 4 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 116: ...3 86 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 196: ...4 80 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 218: ...5 22 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 228: ...A 10 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 232: ...B 4 W A N s u i t e 5 2 6 0 5 2 3 0...