![Verilink Wansuite 5230 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/verilink/wansuite-5230/wansuite-5230_reference-manual_1004298059.webp)
W e b S e r v e r I n t e r f a c e
3-29
Message Size
Maximum number of characters to buffer before sending a frame.
Values: 0
−
1024
Default: 256
Idle Character Delay
Maximum number of idle character time to wait before sending a frame.
Values: 0
−
65535
Default: 10
Input Terminator
Character that terminates a message before sending a frame.
Values: 0
−
255
Default: 0
Data Direction
Data direction that the port will support. If set to “Input,” the port will only
accept incoming data and will not transmit data. If set to “Output,” the port
will ignore any incoming data. If set to “Both,” the port will process all data.
Values: Input, Output, Both
Default: Both
The table below these parameters displays the SCADA statistics.
The SCADA Details screen provides the following user-activated buttons:
Figure 3.22
SCADA Device List Screen
Click the “SCADA Device Details” button to access a menu (Figure 3.23)
that lets you map SCADA devices to endpoints.
Button
Function
Submit
Sets any values that have been changed.
SCADA Device List
Displays a menu that shows the mapping between
SCADA devices and endpoints (Figure 3.22).
Clear Stats
Clears all SCADA statistics.
Refresh
Refreshes data on the current page.
Содержание Wansuite 5230
Страница 1: ...i WANsuite 5260 5230 Reference Manual April 2002 34 00304 F...
Страница 4: ...iv W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 30: ...2 4 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 116: ...3 86 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 196: ...4 80 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 218: ...5 22 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 228: ...A 10 W A N s u i t e 5 2 6 0 5 2 3 0...
Страница 232: ...B 4 W A N s u i t e 5 2 6 0 5 2 3 0...