24. Reset some parameters in the system. 

Press the settings icon in the main menu to select the reset menu and select the parameters you want to 

reset. 

 

25. Setting up the entrance station. 

Press the "settings" icon in the main menu, select "device configuration ",then "List of input stations ", and 

select the desired input station , go to "Edit ", enter 

correct password (default password is "0") 

 

and confirm with the "#" icon. Here you can set all 

theparameters of the

 entrance

 station. 

 

26. Device number. 

The device number is 8 digits, you can set any one. If there is more than 1 entry station in the system, 

you must not use the same device number for 2 input stations. 

 

27. Button address. 

By default, the address is button 1, and the default address of the monitor room is also 1. 

After installation, you can call the internal monitor. If you have changed the "room address" on the 

monitor,  

you must also set a call target for the input station buttons. 

Settings: Select the button 1 address menu in your input station settings and set the room address of the 

monitor you want to call. After setting up, you can press the button at the entrance station to call monitors 

with the room address set. 

Note: If

 the button address is not set in the same way as the address of the target 

monitor, the monitor can monitor the input station, but the input station cannot call the monitor. 

 

28. Private equipment. 

If this feature is enabled, the input station can be set up as a private device for only one family. A private 

entry station can only be monitored by this family and can only be called to this family.

 

 

29. Monitor 

(monitor). 

If this feature is enabled, the input station can be monitored by internal monitors. 

If you disable this feature, the monitors will not monitor the input station. 

 

30. Unlock with monitor. 

If this feature is enabled, you can unlock the door or gateway in the tracking state by pressing the "Unlock" 

icon. If you disable this feature, you can unlock the door or gateway only when you make a call by pressing 

the unlock icon. 

 

31. State of the door lock. 

If you connect a door lock to the system, you must enable this function, set 

"Unlock time " and by lock type "Unlock signal type" (Normally open or Normally closed). 

 

32. The state of the gate lock. 

If you connect a gateway lock to the system, you must enable this feature, set 

"Unlock time " and by lock type "Unlock signal type" 

(Normally open or Normally closed). 

 

33. Type of outgoing button. 

Set the target of the outbound button control on the door or gateway, depending on the actual 

installation. Press the exit button to open the door/gate lock. 

 

Содержание Veria 8276B

Страница 1: ...VERIA User s guide Videophone Model Veria 8276B Please read this manual carefully before use and keep it in case of further need...

Страница 2: ...System settings 13 19 Setting the password 13 20 Password protection list input stations 13 21 Setting the address of the room 14 22 Set the monitor name 14 23 Setting the name of the entry station 1...

Страница 3: ...conditions may result in damage fromthe device injury to the property orfire Do not bend or unplug the power cord from the mains by force If it is damaged there is a risk of fire or electric shock Do...

Страница 4: ...2 Features and description of the device Name 1 Speaker 2 Lcd 3 Microphone 4 Button menu 5 SD Card Slot 6 Back button 7 Left button 8 Right button 9 Call button 10 Track button 11 Open button...

Страница 5: ...ents and contact your dealer immediately Package contents Monitor Wall mount Terminals Screw M3x20mm 2pcs Dowle 2pcs Power adapter 5 Installation Note For trouble free videophone operation please obse...

Страница 6: ...specification N O Item Content 1 Display Colour 7 LCD 800 x 400 2 Intercom type Hands free 2 Connection 2 wire 4 Sound distortion Less than 3 5 Frequency response 400 3 5K 6 Wire length Maximum 200 me...

Страница 7: ...ntacts 1 Power contact DC24V 1A Max 2 SW1SwitchNo To adjust the contact of the2 wirebus Setting Set the last monitor on the2 wirebus to set the SW1 to the ON position Other SWmonitorsto off position 3...

Страница 8: ...6 Connectivity options 230V 24V DC adapter 1 1xmonitor 1x access station...

Страница 9: ......

Страница 10: ...2x monitor 1x entry station 4x monitor 2x entry station 5x monitor 1x entry station...

Страница 11: ...stedon the screen Icon Function Accept Hang Volume Buy Photograph Buy Video Unlock gate or door View or hide icons on the screen Press to answer the call and talk to the visitor After the call is over...

Страница 12: ...Call history Press the recent icon in the call menu to view historie Press from the list of anycall to makea call 4 Favorites Pressing andsubduingany call in history will appear on the screen The icon...

Страница 13: ...on on themain menuto go tothe videolist and press the selected video to start it by pressing the icon or viewing theprevious or subsequent video recording Pressing anddeleting theselectedphotoor video...

Страница 14: ...ote 1 The DVR only records video recording without sound 2 A minimum 2G SD card is required to support DVR function 16 GB recommended or 32 GB SD card 3 If motion is detected it is recorded at normal...

Страница 15: ...ps restart the monitor and go to settings After restarting the monitor a password is not required for the first entry into the settings Go to the Password Protection menu and set your password as need...

Страница 16: ...tton address is not set in the same way as the address of the target monitor the monitor can monitor the input station but the input station cannot call the monitor 28 Private equipment If this featur...

Страница 17: ...set a beep will sound from the entrance station 39 Adjust the volume of the bell speaker You can adjust the volume from 10 to 100 as needed 40 Adjust the angle of view You canset the angle of viewfort...

Страница 18: ...ss Low Normal High Adjust the brightness of the screen 5 Alarm clock Set an alarm Alarm volume Set 10 100 Alarm 1 2 3 4 5 6 You can set each alarm separately Alarm status Turn the alarm function on of...

Страница 19: ...try stations View Edit You must enter the correct password to enter the input station settings Cancel Button address to set the target address of button calls to the input station Private device If en...

Страница 20: ...m Update the program Note In a standby or DVR calendar the device will be in screen saver state if no operation is performed within 4 hours Warranty SAFE HOME europe s r o as a supplier guarys to the...

Страница 21: ...Website www veria eu SAFE HOME europe s r o reserves the right to modify and change product specifications without notice All materials are carefully inspected but the company SAFE HOME europe s r o i...

Отзывы: