Vantage 3000 P
Version 3.4v-01/2019
27 | Page
27 | Page
12.4 Analogue Connector
• Connector Layout
Figure 6 25 Way ‘D’ Type Connector
• Connector Description:
12.5 Foot /Hand Switch Control
Foot switches can be used to remotely turn the pump on and off, freeing the hands to perform other operations or
providing ergonomic improvement at a workstation.
Figure 7 Connecting the Footswitch
PIN
I/O
FUNCTION
6
IN
FORWARD RUN INPUT
7
IN
REVERSE RUN INPUT
10
OUT
5 VOLT SUPPLY (to potentiometer)
11
IN
0-5 VOLTS INPUT
12
IN
4-20mA INPUT
13
IN
0-10 VOLTS INPUT
14
OUT
RUNNING OUTPUT (5V)
15
OUT
STOPPED OUTPUT (5V)
16 to 25
OUT
0 VOLTS (internally connected to zero volts in the pump)
Table 12 Analogue/Digital Connector Pins
Footswitch
25 way “D” connector
Vantage 3000
13
25
1
14
5V
0-5V
4-20mA
0-10V
REV I/P
RUN I/P
RUN O/P
OV
ST
OP
O/
P