Vantage 3000 P
Version 3.4v-01/2019
25 | Page
11 Remote Interface
11.1 Manual Mode
•
Momentarily operate CW or CCW run from keypad and the
pump runs until STOP is pressed.
•
Momentarily operate CW or CCW run from remot interface
and the pump only runs for as long as the input is on. Con-
tinuous operation requires the input to be maintained.
11.2 Memo-Dose Mode
•
Momentarily Operate CW or CCW run from keypad and
the pump runs for that memo period then stops.
•
Momentarily operate CW or CCW run from keypad again
and the operation repeats as a “One shot operation”.
•
Operate CW or CCW run from remote interface and the
pump only runs for as long as the input is on. The input
must be maintained throughout the duration of the dose
period for the dose cycle to complete. When the Memo-
dose has completed, the input must then be unlatched and
re-latched again to allow the Memo-dose to restart.
11.3 Dose Mode
•
Momentarily operate CW or CCW run from keypad and the
Dose program repeats indefinitely.
•
Operate CW or CCW run from the remote interface and
the pump will run the dose cycle then stop at the end of
one dose (“One shot”) unless the input is maintained.
Maintaining the input allows the dose to repeat indefinitely
(“cyclic”)
11.4 Batch Mode
•
Momentarily operate CW or CCW run from keypad and the
batch program runs.
•
The batch count decrements automatically when the time-
out period of the previous batch count has elapsed.
•
Operate CW or CCW run from the remote interface and
the pump will dose one batch count then stop at the start
of the next batch count, unless the input is maintained.
Maintaining the input allows the batch to continue its dec-
rement count until it reaches zero. If the input is not main-
tained it can be decremented as a “One shot” operation by
momentarily tripping the remote input until count = zero.
*(Please Note: Keypad operation has priority over the remote
interface)
Figure 3 IP66 Computer Control
(3: TURN ON PUMP)
(2: INSTALL PC PUMP PROGRAM)
(1: INSERT DISC)
IP 66 SOFTWARE BUNDLE
PROGRAMMABLE DISPENSER
NULL MODEMRS232
(IP66)