Operation, Maintenance & Safety Manual
Version 7.01 January 2006
13
4.2.3 Assembling the pump
Figure 2a
Before assembling the pump it is advised to
clean down the cavity of the pump body to
remove any debris.
Figure 2b
Using a bearing press, press the bearings
into the front and rear of the pump body.
Figure 2c
The shaft seal should be pressed on top of
the inner bearing with the sprung lip facing
into the pump cavity.
Figure 2d
It is also important at this point to attach the
filler tube to the back of the pump as it could
be difficult to attach once the GMU is in
place. Line the thread of the breather tube
with PTFE tape and tighten into position to
give a leak free seal.