Rev 1.1 Cod. 00.009.126
24
CONNECTIONS
A -
Power cable, 90-250V-50-60Hz
B -
Enable input (dosing consent)
(110Vac; 230Vac; upon request 24V).
OPTIONAL
C -
BNC connector for pH probe or Rx probe.
D -
Level probe connector (3 and 4 contacts).
OPTIONAL
.
E -
BNC connector for temperature probe.
OPTIONAL
F -
Flow sensor connector (3 and 4 contacts).
OPTIONAL
G
-
Alarm
output connector (3 and 4 contacts).
( 5A 250Vca/30Vdc) NORMALLY OPEN.
OPTIONAL
H
– ON_OFF switch.
OPTIONAL
DEFAULT SETTINGS
PASSWORD
= Not programmed
Delay On
: 0 minutes
Enable (optional)
: active
Broken Hose (optional)
: active
TAL
: 0 unit (disabled)
Flow (optional)
: Normally Open
Temperature
: PT100 (probe is optional)
pH:
Dosing:
Proportional
SetP (setpoint):
7.2 pH
T.MAX (maximum threshold):
8.2pH
Flow.Max (maximum flowrate):
80%
Delay On:
3 sec (0-999sec)
Rx:
Dosing:
Proportional
SetP (setpoint):
730mV
T.MAX (maximum threshold):
630mV
Flow.Max (maximum flowrate): 8
0%
Delay On:
3 sec (0-999sec)
DEFAULT SETTINGS RESTORE
3sec
Keep pushing for 3 seconds the
ENTER / MENU
button to
enter into the programming menu.
Move the cursor > to Utility by pressing
▼.
Push
ENTER
button to enter the submenu.
Push ▼ button to move the cursor to “Reset”.
Push
ENTER
button
to confirm
.
By pushing the ▼ button choose “YES” to confirm and push
ENTER
button.
Choose to restore the "Programming Parameters". Press
ENTER
.
Automatically the pump restores the factory settings.
Press the
ESC
button for 3 seconds to exit programming.