Maintenance
8
|
P a g e
2.0v-04.2013
FL-Auto control
Verderflex Vantage 3000 C
2.0v-12.2013
8
|
P a g e
Rotor setting distance
2.5mm
7.3
S10 Head
7.3.1
Key features
Taken from the Verderflex Smart tube pump
design. The S10 includes a quick tube change,
ergonomic design for ease of use.
Flow rates up to 1,780 ml/min (28 US
GPH)
Pressures up to 2 Bar (29 PSI)
Multi channel options
Typically used in:
-
Chemical dosing
-
Industrial fluid transfer
-
Heavy duty environments
7.3.2
Installing the tube
1. Insert tube on top of the rollers
2. Fit the saddle to one set of dowels
3. Open up the lever and fit the claw over
4. Push the lever down to lock the saddle into
place over the other set of dowels
7.4
R3i head
7.4.1
Key features
Robust design with thick wall tube for suction
and pressure handling.
Flow rates up to 3,250 ml/min (51.5 US
GPH)
Pressures up to 2 Bar (29 PSI)
Typically used in:
-
Printing production
-
Dispensing
-
Industrial detergent applications
7.4.2
Installing the tube
1. Remove the clamp, but leave the front cover
in place
2. Run the pump at low speed and carefully
feed tube through the inlet
3. When tube reach outlet,use blunt end rod to
guide the tube out.
4. Fit tube clamp loosely, and position tube
with marked lines adjecent to edge of pump
housing and tube clamp.
5. Tighten the tube clamp securely
7.4.3
Changing rotor – R3i head
1. Align grub screw hole with flat on shaft
2. Align peak of roller with peak of tube track or
set rotor distance back from front of pump
housing
3. Fasten grub screw securely
Table 6 Installing tube – S10 head
1
3
4
2
Table 8 Replacing the rotor – R3i head
Blunt rod to
guide tube
Feed tube carefully
from inlet side
Align tube marks
Protective front
cover remains
in place
Fastening
grub screw
1
2
Table 7 Installing tube – R3i head