Maintenance
Verderflex Vantage 3000 C
2.0v-12.2013
5
|
P a g e
1
About the product
The Verderflex Vantage 3000
©
range of pumps deliver
highly accurate and repeatable flow rates with a quick
and easy setup. Vantage 3000 C is a manual/analogue
control, easy tube load pump with stackable and multi
channel
pump head
options and require
low
maintenance.
1.1
Key features
-
Microprocessor controlled 24 hour duty with brushless
dc motor
-
Set precise dose requirement and calibrate to suit
medium viscosity
-
Stackable and multi channel head options
-
Keypad operated with two line alpha numeric display.
-
Volt free contacts for external Start/Stop/Reverse
-
Manual and analogue control of speed/flow rate
2
Warranty
The manufacturer does not accept any liability for
damage resulting from disregard of this documentation.
This product is guaranteed to be free from defects in
material or workmanship for a period of 24 months from
date of purchase, excluding consumable items such as
cartridges, tubing or rollers. Products out of guarantee
period will be repaired for a nominal charge.
3
Pump returns
All returned pumps must be decontaminated before being
returned. The Decontamination Certificate is separately
requested and must be returned before or with the pump
delivery. For your protection, items returned must be
carefully packed to prevent damage in transit and insured
against loss.
4
‘EC’ Declaration
The Vantage 3000 range, complies with EMC 2004/ 108/
EC as well as Machine Directive 2006/42/EC.
Installation of this pump into other equipment must be in
accordance with relevant Directives/Standards and be
carried out by a suitably competent person.
5
Safety
The manufacturer does not accept any liability for
damage
resulting
from
disregard
of
this
documentation.
5.1
Intended use
•
Only use the pump to handle c o m p a t i b l e fluids as
recommended by the manufacturer.
•
Adhere to the operating limits.
•
Consult the manufacturer regarding any other use of the
pump.
5.2
Prevention of obvious misuse
•
Note the operating limits of the pump with regard to
temperature, pressure, flow r a t e a n d m o t o r
s p e e d .
•
Do not operate the pump while the inlet/outlet valve is
closed.
•
Only install the pump as recommended in this manual.
For example, the following are not allowed:
– Installing the pump without proper support.
– Installation in the immediate vicinity of extreme hot
or cold sources.
•
Do not use in conjunction with life support equipment
•
Do not connect pump to the human body
Risk of electrocution!
Make sure that the electrical information on the rating
plate agrees with the power supply.
Isolate the main supply before replacing the
tube/cartridge
Isolate the main supply before removing the enclosure
cover
6
Maintenance
Motor and Gearbox are lubricated for life and should not
require attention. Rotor rollers are self-lubricated. Pump
tubing will not last forever; establish suitable tube
replacement schedule to prevent inconvenient tube
failure
This pump contains no user serviceable parts and is
factory sealed to confirm integrity. Pump warranty will
be invalidated if the seal is broken.
7
Pump head options and
Installation
- Pump should be installed by suitably qualified
personnel
- Pump should be sited on stable horizontal surface
- Allow free flow of air around pump
- Tube should not be allowed to kink.
DANGER
Figure 1 Tamper proof lable