Rapide
2.0v-11.2019
18 | Page
5.4.3 Rotor Assembly Replacement
u
Isolate the pump from the main power supply before
opening the pump door or performing any positioning,
removal or maintenance operation.
Before removing the rotor assembly, make sure the tube has
been correctly removed. (
g
5.4.1 Installing Continuous Tube)
1. Unscrew the M4 bearing strut retaining screw using a
screwdriver. (No.2 posidrive)
2. Remove the bearing strut.
3. Remove the rotor assembly by hand.
This may take some effort due to assembly fit.
4. Bearing strut and rotor assembly have been removed.
5. Push replacement rotor into rear pump head bearing.
Ensure the rotor assembly is fully pressed in.
6. Replace the bearing strut and tighten the retaining screw.
The tightening torque value for the retaining screw is 1.5 Nm.
Figure 13 Rotor Assembly Replacement - Rapide 5000
Note
DANGER
Note
Note
Note
1
2
3
4