![VERDER Verderflex Rapide Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/verder/verderflex-rapide/verderflex-rapide_original-operating-manual_1003786013.webp)
Rapide
2.0v-11.2019
13 | Page
5 Installation and Connection
Material damage due to unauthorized modification on
pump
u
Unauthorized modification will invalidate the warranty.
5.1 Electrical Installation
Failure to follow safe and proper electrical installation
practices may result in pump malfunction or dangerous
operation
u
Make sure the pump is installed correctly.
u
The pump is supplied with a pre-fitted main lead which is
not a user-replaceable part.
u
The mains lead may have a fuse fitted (country
dependant)
u
The fuse should be replaced with an identical fuse in the
event of the fuse blowing.
5.1.1 Checking the Ambient Conditions
1. Make sure that the operating conditions are corrected.
(
g
Appendix A
)
2. Make sure the required ambient conditions are fulfilled.
(
g
Appendix A
)
5.1.2 Installing the Gear Motor Unit for
Rapide and Rapide ‘S’ (where not sup-
plied)
1. Lift motor and gearbox using suitable lifting gear.
2. Apply anti seize grease to the gearbox shaft.
3. Offer gearbox shaft up to the adaptor sleeve.
4. Align key to the key way.
5.
Connect motor to the rated power supply. Ensure the
correct gland is used and that the earth connection is
made and secured.
6. Run the pump to ensure correct direction of rotation.
CAUTION
CAUTION
5.1.3 Connecting to a Power Supply
Risk of electrocution!
u
All electrical work must be carried out by qualified
electricians.
u
Make sure that the electrical information.
on the rating plate agrees with the power supply.
u
Isolate the main supply before replacing the tube/
cartridge
u
Isolate the main electrical supply before opening the
pump head/cover.
Checklist:
[
Pump set up and connected properly.
[
Motor set up and connected properly.
[
All connections stress-free and sealed.
[
All safety equipment installed and tested for functionality.
DANGER