Component/Model
Component/Model
Component/Model
U.S.
U.S.
U.S.
Metric
Metric
Metric
Compressor
28 lb
13 kg
Variable
Frequency
Drives
Model
Model
Model
Hp/kW
Hp/kW
Hp/kW
Input
Input
Input Voltage
Voltage
Voltage Range
Range
Range
Nominal
Nominal
Nominal Output
Output
Output Voltage
Voltage
Voltage
†
819.1286
7.5/5.5
170–264 Vac, 3 phase
208–240 Vac, 3 phase
819.1287
7.5/5.5
340–528 Vac, 3 phase
400–480 Vac, 3 phase
†
Output voltage is dependent on input voltage.
Weights
Weights
Weights
Pump Material
Motor/Gearbox
Standard
AC
ATEX AC
Flame-
proof AC
No Gear-
motor
AC5
AC5
AC5
AX5
AX5
AX5
AF5
AF5
AF5
WG
WG
WG
Fluid
Section
Center
Section
lb
kg
lb
kg
lb
kg
lb
kg
Aluminum
Aluminum
280
127
396
179
437
198
138
62
Polypropylene
Aluminum
483
219
387
175
428
194
129
58
Stainless
Steel
Aluminum
547
248
458
208
499
226
200
90
Fluid
Fluid
Fluid Temperature
Temperature
Temperature Range
Range
Range
NOTICE
NOTICE
NOTICE
Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid
temperature range. Stay within the temperature range of the most-restricted wetted component. Operating
at a fluid temperature that is too high or too low for the components of your pump may cause equipment
damage.
Fluid
Fluid
Fluid Temperature
Temperature
Temperature Range
Range
Range
Aluminum
Aluminum
Aluminum Cast
Cast
Cast Iron,
Iron,
Iron, or
or
or
Stainless
Stainless
Stainless Steel
Steel
Steel Pumps
Pumps
Pumps
Polypropylene
Polypropylene
Polypropylene or
or
or Conductive
Conductive
Conductive
Polypropylene
Polypropylene
Polypropylene Pumps
Pumps
Pumps
PVDF
PVDF
PVDF Pumps
Pumps
Pumps
Diaphragm/Ball/Seat
Diaphragm/Ball/Seat
Diaphragm/Ball/Seat
Material
Material
Material
Fahrenheit
Fahrenheit
Fahrenheit
Celsius
Celsius
Celsius
Fahrenheit
Fahrenheit
Fahrenheit
Celsius
Celsius
Celsius
Fahrenheit
Fahrenheit
Fahrenheit
Celsius
Celsius
Celsius
Acetal (
AC
)
10° to 180°F
-12° to 82°C
32° to 150°F
0° to 66°C
10° to 180°F
-12° to 82°C
Buna–N (
BN
)
10° to 180°F
-12° to 82°C
32° to 150°F
0° to 66°C
10° to 180°F
-12° to 82°C
Geolast® (
GE
)
-40° to 150°F
-40° to 66°C
32° to 150°F
0° to 66°C
10° to 150°F
-12° to 66°C
Polypropylene (
PP
)
32° to 150°F
0° to 66°C
32° to 150°F
0° to 66°C
32° to 150°F
0° to 66°C
PTFE check balls or
two-piece PTFE/EPDM
diaphragm (
TF
)
40° to 220°F
4° to 104°C
40° to 150°F
4° to 66°C
40° to 220°F
4° to 104°C
Santoprene® check
balls (
SP
)
-40° to 180°F
-40° to 82°C
32° to 150°F
0° to 66°C
10° to 225°F
-12° to 107°C
TPE (
HY
)
-20° to 150°F
-29° to 66°C
32° to 150°F
0° to 66°C
10° to 150°F
-12° to 66°C
*
The maximum temperature listed is based on the ATEX standard for T4 temperature classification. If you are operating
in a non-explosive environment, FKM fluoroelastomer’s maximum fluid temperature in aluminum or stainless steel
pumps is 320°F (160°C).
859.0634
35
Содержание Verderair VA-E80
Страница 24: ...Dimensions Dimensions Dimensions Dimensions Aluminum pump with compressor 24 859 0634 ...
Страница 25: ...Dimensions Aluminum pump without compressor 859 0634 25 ...
Страница 27: ...Dimensions Polypropylene pump with compressor 859 0634 27 ...
Страница 28: ...Dimensions Polypropylene pump without compressor 28 859 0634 ...
Страница 30: ...Dimensions Stainless steel pump with compressor 30 859 0634 ...
Страница 31: ...Dimensions Stainless steel pump without compressor 859 0634 31 ...
Страница 36: ...Notes Notes Notes Notes 36 859 0634 ...